JVC DLA-M4000LU operating instructions Controls and Features

Page 38

Controls and Features

Front Side / Top Surface / Right Side

 

 

1

1

 

2

 

 

3

7

 

 

 

 

4

6

1

5

Controls and Features (cont.)

Left-hand side / Back Side

p

 

 

9

 

 

8

 

8

 

 

 

3

8

 

 

DLA-M4000LU DLA-M4000LE

No.51666

1Adjustable foot

It is set at the shortest position when shipped from the factory.Turn the foot to make the projector level. Adjustment can be made in the range of ±4° from the vertical and ±5° from the horizontal.

2Connector panel

For details, refer to “Connector Panel” on page 10.

3Air intake area (filter)

Air is taken in through this area to cool the light-source lamp. If this area is blocked or if something that obstructs taking in or exhausting air is placed around the projector, heat may build up inside and could cause a fire. For details, refer to “Precautions for Installation” on page 14.

CAUTIONS

Be careful as paper, cloth or soft cushion could be drawn in if placed nearby. Do not block the intake area, or heat may build up and could cause a fire.

Clean the filter periodically. For details, refer to “Cleaning and Replacing the Filter” on page 59.

Deposition of dirt on the filter works to reduce the cooling effect, causing heat to build up inside, which could cause a fire or malfunction.

4AC IN (power input) terminal

This is the power input terminal where the supplied power cord is connected. For details, refer to page 23.

5MAIN POWER switch

This is the main power switch. When it is turned on, the projector goes into stand-by state, and the STAND BY indicator on the control panel comes on.

ON [ ]: The main power turns on.

OFF []: The main power turns off.

6Remote sensor

When operating with the remote control, aim it toward this sensor. An additional remote sensor is provided on the back of the projector. The effective operating distance of the remote control is 10 m from each of the sensors. The effective operating range of angles is 50° left and right, and 15° up and down.

7Lens mount

Attach a projection lens separately sold to this mount.

GL-M4023SZ 3 : 1~7 : 1 zoom lens

GL-M4015S 1.5 : 1 fixed-focus lens

For information on attaching the lens, consult the dealer or service center who performed the installation and adjustments of your projector.

8Exhaust vents

Vents for cooling fans through which warm air comes out.

9Control panel

For details, refer to “Control Panel” (page 8 and 9).

pRemote sensor

When operating with the remote control, aim it toward this sensor. An additional remote sensor is provided on the front of the projector. The effective operating distance of the remote control is 10 m from each of the sensors. The effective operating range of angles is 50° left and right, and 15° up and down.

6

7

Image 38
Contents Operating For customer UseAbout burning-in of the D-ILA device Lamp directly by opening the cabinet while the illuminationContents Accessories Front Side / Top Surface / Right Side Controls and FeaturesControls and Features Left-hand side / Back SideControl Panel Connector Panel Remote Control UnitMenu / Enter Menu Operation Button Installing BatteriesInstall the batteries Open the back coverInstalling the Projector Installing the ProjectorPrecautions for Installation Relationship relative to Glass SurfaceTo aspect ratio Lens Shift FunctionChange of projection screen according ScreenAdjustable range of the lens Connecting to Various DevicesSignals that Can Be Input to the Projector Projection Distances and Screen SizesRGB output devices Example of a basic systemDesktop type Power cord into a wall outlet, Connecting to Devices which Control the ProjectorConnecting the Power Cord Supplied Insert the plug of the suppliedTurning off the Power When Turning On the Devices Connected to the ProjectorTurning on the Power Basic OperationsFor Operating Other Functions Adjust the screen sizeAdjust focus Basic OperationsProjector’s button To display the Setting menuTo use the remote control’s Preset button To display Channel on the screenPress the Setting button of the projector Operating the Setting Menu Operating the Main MenuMaking Basic Settings Press the Setting button to select the desired itemConfiguration of the Main Menu Computer-related input Operating the Main Menu Basic Operation of the Main MenuPress MENU/ENTER toward the 5 or ∞ mark to select Decoder Changing the Color SystemChanging the Language Display Press MENU/ENTER toward the 2 or 3 mark to setAdjustment item Button Adjustment content Adjusting the Pixel ClockAdjusting the Screen Position To return to the main menu, pressAdjusting Picture Quality Submenu itemsAbout the lamp use time Setting and Adjusting Other Functions OptionsFollowing optional functions can be set adjusted Picture menuOptions menu Adjustment item ButtonDisplay, the video image resolution becomes coarse Press the MENU/ENTER button Submenu Changing Setting the SourcePress MENU/ENTER to set fix Press MENU/ENTER to set Setting Up ChannelsPress the MENU/ENTER button to set Channel setup selection menu Setting Up Channels Line setupSetting Up Channels Source setup When Line is selectedPress the page Back button to set Setting Up Channels SWNo. setupWhen a switcher number SWNo is selected Changing Channels CH Change Setting Up or Changing User Sources Mark to select a submenu item Remote control unit Press the MENU/ENTER button to setSetting Up or Changing the Display Size Remove the filters Cleaning and Replacing the FilterRemove the filter cover screws To return to the main menu, press page BACK. To finishReinstall the filters TroubleshootingClean the filters About Light-Source Lamp ReplacementWhen the emergency indicator starts blinking TroubleshootingEXT. in AV in input SpecificationsSpecifications RGB in RGB inputDTV-format signals DLA-M4000LE Instructions Victor Company of JAPAN, LimitedImproper adjustment of controls may result in damage Important InformationContents Controls and Features Temp indicator On When in stand-by mode Blinking When in cool-down modeOn When the projector is in operation projecting Input of external sync signals is automatically detected 51666 305 mm 600 mm 11.392 Type