JVC DLA-HD10KU/E Installing the Projector, Precautions for Installation, Installation Environment

Page 18

Installing the Projector

Precautions for Installation

Please read the following carefully when installing this unit.

Installation Environment

This unit is a precision device. Do not install it at the following places. Doing so may cause fire or malfunction of the unit.

Where there is water, humidity or dust

Where the unit may be subjected to oily or cigarette smoke

On a soft surface such as carpet or cushion

Where the unit may be subjected to high temperature due to direct sunlight

When temperature is high or low

Allowable operation temperature range: +5 f to +35 f

Allowable relative humidity range: 20 % to 80 % (no condensation)

Allowable storage temperature range: -10 f to +60 f

Any room in which there is cigarette smoke or grease Even where smoke and grease levels are minimal, prolonged exposure will affect this unit. This unit emits heat and optical components are cooled down by taking in a large amount of air. The optical path may be soiled by grease/dirt, thus causing images to become dark or color projection to deteriorate. When soiling on the optical components occurs, removal of grease/dirt totally will not be possible.

Precautions for Usage

This unit makes use of a light source lamp that may reach a high temperature during projection. Do not allow projection under the following conditions. Doing so may cause fire or malfunction of the unit.

Projection with the unit laid on its sides

Projection with the unit installed in an unreasonable angle

Avoid using this unit at an angle of more than 5  horizontally and 25  vertically. Doing so may cause unevenness in the color or shorten the lamp life.

Projection at a location that blocks the air inlets or exhaust vents

Projection at a place exposed to air blasts from an air- conditioner

Minimum Space Required

150 mm and above

Do not use a cover which may enclose this unit or block the air inlets/exhaust vents. Allow sufficient space around this unit. When this unit

300 mm and above

150 mm and above

300 mm and above

500 mm and above

is enclosed in a space of dimensions as indicated on the left, use an air-conditioner so that internal and external temperatures are the same.

18

Image 18
Contents For Customer use Pour utilisation par le clientSafety Precautions Machine Noise Information Germany onlyPower cord EnglishSafety Precautions How To Replace The FuseBusiness users Other Countries outside the European Union Information for Users on Disposal of Old Equip- mentEuropean Union Benutzerinformationen zur Entsorgung alter Geräte HinweisUnione Europea Unión EuropeaEmpresas Otros países no pertenecientes a la Unión Europea União EuropeiaEuroopan unioni Brugerinformation om bortskaffelse af gammelt udstyr BemærkProfessionelle brugere Lande uden for EU Yrityskäyttäjät Muut maat Euroopan unionin ulkopuolellaЕвропейский Союз About Burning-in of D-ILA Device Maintenance ProceduresStandard for gauging replacement time of components Viewing Conditions Brightness of RoomContents AccessoriesControls and Features Front Side/Top Surface/Bottom SurfaceControls and Features Rear Side/Right SideHandling the Control Panel Cover Control Panel Indicators Indicator Display on the Control Panel Indicator DisplayIndicator Display on the Top Surface Indicator DescriptionRemote Control Load the batteries Loading Batteries into the Remote ControlOpen the back cover Close the back coverInstallation Environment Installing the ProjectorPrecautions for Installation Precautions for UsagePrecautions for Ceiling-mount Mounting this UnitWhen viewed from the left or right Installing the ProjectorProjector and Screen Installation When viewed from the top or bottomDLA-HD10KU/E Screen Size and Projection DistanceDLA-HD10KSU/E Approximate Projecting DistanceProject the image on the screen Lens Shift SettingAdjust the projection screen position Remove the lens shift coverEffective Range of Remote Control Unit When reflecting off a screenWhen directing remote control unit toward this unit Connecting to Devices Connecting to Various DevicesConnecting to Devices Control from external deviceConnecting the Power Cord Supplied Adjusting zoom screen size Basic Operation ProceduresTurning on the power Removing the lens capPrecautions During Use Adjusting focusTurning off the power Hiding the image temporarilyAdjustments and Settings Using Menus Menu StructureMenu Operation Buttons Button Remote This Unit Function Control UnitAfter setting is completed, press the Exit button Adjustments and Settings Using MenusProcedures for Menu Operation Press the Menu buttonMenu Configuration Sleep Time Power SaveOptions Menu Menu Display RC232C bpsScreen Masking Project image onto the screenPress the Menu button to end Picture Shift Setting Replacing the Lamp About Lamp ReplacementOWhen the lamp usage time reaches 2010 hours Light-source Lamp and Lamp Usage TimeProcedure for Lamp Replacement Attach the lamp cover and fasten the screw Insert the lamp unit until it is fullyTighten the screws of the lamp unit and close the handle Attach the control panel coverResetting Lamp Time Insert plug into the power outletTo ensure the lamp time has been reset Clean the filter Cleaning and Replacing the FilterPull out the plug from the power outlet Reinstall the inner filterWhat to do when these messages are displayed Message Cause DetailsAbout warning indicators Please follow the procedures belowActions to be taken upon warning indications Troubleshooting Symptom Probable Cause Corrective Action Reference Remote WorkPin Arrangement Pin No Signal NameTerminal Description RS-232C TerminalHeader Command Parameter Communication SpecificationsCommand Format RS-232C External ControlExternal control command table Terminal DescriptionSpecifications Front SpecificationsDimensions Unit mm Top Bottom SideMemo DLA-HD10KU/E/DLA-HD10KSU/E
Related manuals
Manual 50 pages 25 Kb