JVC DLA-HD10KSU/E, DLA-HD10KU/E manual Replacing the Lamp, Light-source Lamp and Lamp Usage Time

Page 35

Replacing the Lamp

Light-source Lamp and Lamp Usage Time

The life of light-source lamps used for this unit is about 2000 hours.

The lamp life of 2000 hours is merely the average life span of light-source lamps and we do not provide any guarantee for this figure.

The lamp life may not reach 2000 hours depending on the operating conditions.

Deterioration progresses rapidly when the remaining lamp usage time is short. Get ready or replace with a new lamp (lamp unit) when the accumulated usage time exceeds 1900 hours. Depending on the operating conditions, the lamp may have to be exchanged earlier. If the image is dark or color tone abnormal, replace the lamp as soon as possible.

You can also check the accumulated hours of usage. Please refer to ALamp TimeB of the AInformationB menu. (A Pages 28, 32)

Setting APower SaveB of the AOptionsB menu to AOnB does not affect the usage time of the light-source lamp. (A Pages 28, 32)

Please consult your authorized dealer when purchasing a new lamp unit.

oReplacement Lamp (Lamp Unit) Part No.: BHL5008-S

ENGLISH

oWhen the lamp usage time exceeds 1900 hours (but less than 2000 hours)

The [LAMP] indicator lights up and the [TEMP] indicator starts blinking upon turning on the power (standby mode).

The ALamp replacementB message will be displayed on the screen when projection starts.

The message can be cleared by pressing any button on the remote control or this unit.

oWhen the lamp usage time exceeds 2000 hours (but less than 2010 hours)

The [LAMP] indicator lights up and the [FAN] indicator starts blinking upon turning on the power (standby mode).

When the lamp usage time exceeds 2000 hours during projection, the ALamp replacementB message will be displayed on the screen when projection starts and the AWarningB mark will appear blinking.

Press the [EXIT] button to clear the display. However, the same AWarningB and ALamp replacementB messages will be displayed after 1 hour.

When the unit is switched to the standby mode or turned off after the lamp usage time exceeds 2000 hours, it cannot be switched back to the projection mode again. In this case, replace with a new lamp (lamp unit) and reset the lamp time (A Page 38).

oWhen the lamp usage time reaches 2010 hours

The unit quits the projection mode (operating mode) and switches into the cool down mode.

The [LAMP] indicator will light up and the [TEMP] and [FAN] indicators will appear blinking.

The projection mode (operating mode) cannot be restored until a new lamp (lamp unit) is replaced and the lamp time reset.

About Lamp Replacement

If this unit is installed in a constricted place, attempting to replace the lamp in that place may cause injury. Move this unit to a place large enough to perform work.

Use only genuine replacement parts for the lamp unit. Otherwise, malfunction may occur. Also, never attempt to re-use an old lamp unit. This may cause marked performance deterioration or lamp blowout, thus leading to unit malfunction. Broken pieces of the lamp outside this unit may also cause injuries during lamp unit exchange.

Do not replace the lamp immediately after this unit has been used. The temperature of the lamp is still high and this may cause a burn. Allow a cooling period of 1 hour or more before replacement.

Before replacing the lamp unit, pull out the power plug from the outlet while the [STAND BY] indicator is still on. Replacing a lamp with the plug connected to the outlet may cause injuries or electric shocks.

35

Image 35
Contents Pour utilisation par le client For Customer useMachine Noise Information Germany only Safety PrecautionsEnglish Power cordHow To Replace The Fuse Safety PrecautionsBenutzerinformationen zur Entsorgung alter Geräte Hinweis Information for Users on Disposal of Old Equip- mentEuropean Union Business users Other Countries outside the European UnionUnião Europeia Unión EuropeaEmpresas Otros países no pertenecientes a la Unión Europea Unione EuropeaYrityskäyttäjät Muut maat Euroopan unionin ulkopuolella Brugerinformation om bortskaffelse af gammelt udstyr BemærkProfessionelle brugere Lande uden for EU Euroopan unioniЕвропейский Союз Viewing Conditions Brightness of Room Maintenance ProceduresStandard for gauging replacement time of components About Burning-in of D-ILA DeviceAccessories ContentsFront Side/Top Surface/Bottom Surface Controls and FeaturesHandling the Control Panel Cover Controls and FeaturesRear Side/Right Side Control Panel Indicators Indicator Description Indicator DisplayIndicator Display on the Top Surface Indicator Display on the Control PanelRemote Control Close the back cover Loading Batteries into the Remote ControlOpen the back cover Load the batteriesPrecautions for Usage Installing the ProjectorPrecautions for Installation Installation EnvironmentMounting this Unit Precautions for Ceiling-mountWhen viewed from the top or bottom Installing the ProjectorProjector and Screen Installation When viewed from the left or rightApproximate Projecting Distance Screen Size and Projection DistanceDLA-HD10KSU/E DLA-HD10KU/ERemove the lens shift cover Lens Shift SettingAdjust the projection screen position Project the image on the screenWhen directing remote control unit toward this unit Effective Range of Remote Control UnitWhen reflecting off a screen Control from external device Connecting to Various DevicesConnecting to Devices Connecting to DevicesConnecting the Power Cord Supplied Removing the lens cap Basic Operation ProceduresTurning on the power Adjusting zoom screen sizeHiding the image temporarily Adjusting focusTurning off the power Precautions During UseMenu Structure Adjustments and Settings Using MenusButton Remote This Unit Function Control Unit Menu Operation ButtonsPress the Menu button Adjustments and Settings Using MenusProcedures for Menu Operation After setting is completed, press the Exit buttonMenu Configuration RC232C bps Power Save Options Menu Menu Display Sleep TimePress the Menu button to end Screen MaskingProject image onto the screen Picture Shift Setting Light-source Lamp and Lamp Usage Time About Lamp ReplacementOWhen the lamp usage time reaches 2010 hours Replacing the LampProcedure for Lamp Replacement Attach the control panel cover Insert the lamp unit until it is fullyTighten the screws of the lamp unit and close the handle Attach the lamp cover and fasten the screwTo ensure the lamp time has been reset Resetting Lamp TimeInsert plug into the power outlet Reinstall the inner filter Cleaning and Replacing the FilterPull out the plug from the power outlet Clean the filterMessage Cause Details What to do when these messages are displayedActions to be taken upon warning indications About warning indicatorsPlease follow the procedures below Troubleshooting Work Symptom Probable Cause Corrective Action Reference RemoteRS-232C Terminal Pin No Signal NameTerminal Description Pin ArrangementRS-232C External Control Communication SpecificationsCommand Format Header Command ParameterTerminal Description External control command tableSpecifications Bottom Side SpecificationsDimensions Unit mm Top FrontMemo DLA-HD10KU/E/DLA-HD10KSU/E
Related manuals
Manual 50 pages 25 Kb