JVC DLA-HD10KU/E manual Options Menu Menu Display, Sleep Time, RC232C bps, Zoom/Focus, Power Save

Page 32

Adjustments and Settings Using Menus (continued)

C Options Menu

................................................................................................

Menu Display

Adjusts the display duration of the menu screen. Setting Values: A15secB,AOnB

Default Value: A15secB

The menu screen display will not disappear automatically when this is set to AOnB. Press the [EXIT] button to clear the menu screen.

................................................................................................

Sleep Time

Sets the lapse time before automatically switching the unit to the standby mode when there is no signal input.

Setting Values: A15minB,A30minB,A60minB,AOffB

Default Value: AOffB

................................................................................................

RC232C (bps)

Sets the communication speed (signal transmission speed) when communicating with a computer using the RS-232C terminal. Ensure that this is same as the rate set at the computer.

Setting Values: A9600B,A19200B

Default Value: A19200B

................................................................................................

Zoom/Focus

Locks/Unlocks the power zoom/power focus functions of the projection lens.

Setting Values: ALockB,AUnlockB

Default Value: AUnlockB

................................................................................................

Power Save

Switches the power (brightness) of the light-source lamp. Setting Values: AOnB,AOffB

Default Value: AOffB

It is possible to lower the power (brightness) of the light- source lamp when this is set to AOnB, but the display will appear darker than when this is set to AOffB.

Adjustment of settings will be disabled for about 1 minute after the setting is changed. In this case, adjust settings after a lapse of at least 1 minute.

Altering the AOnB,AOffB setting does not affect the lamp usage time (lamp life) of the light-source lamp.

D Information Menu

................................................................................................

Lamp Time

Displays the accumulated hours of usage of the light- source lamp.

................................................................................................

Source

Automatically identifies the input video signal at the [DVI] terminal of this unit and displays the signal name (A1080p50B or A1080p60B).

When there is no video signal input to the [DVI] terminal, or when there is input of a video signal that cannot be used with this unit, no signal name will be displayed.

NOTES:

When the input video signal is switched, a blue back image will appear for about 2 seconds.

When nothing is connected to the [DVI] terminal, or if there is no video signal, a ANo Signal DVI-DBmessage will be projected.

For a video signal that cannot be used with this unit, a AOut of RangeB message will be projected.

Video input signals that can be used with this unit are 1080/50p and 1080/60p signals by DVI-D.

32

Image 32
Contents For Customer use Pour utilisation par le clientSafety Precautions Machine Noise Information Germany onlyPower cord EnglishSafety Precautions How To Replace The FuseInformation for Users on Disposal of Old Equip- ment European UnionBusiness users Other Countries outside the European Union Benutzerinformationen zur Entsorgung alter Geräte HinweisUnión Europea Empresas Otros países no pertenecientes a la Unión EuropeaUnione Europea União EuropeiaBrugerinformation om bortskaffelse af gammelt udstyr Bemærk Professionelle brugere Lande uden for EUEuroopan unioni Yrityskäyttäjät Muut maat Euroopan unionin ulkopuolellaЕвропейский Союз Maintenance Procedures Standard for gauging replacement time of componentsAbout Burning-in of D-ILA Device Viewing Conditions Brightness of RoomContents AccessoriesControls and Features Front Side/Top Surface/Bottom SurfaceHandling the Control Panel Cover Controls and FeaturesRear Side/Right Side Control Panel Indicators Indicator Display Indicator Display on the Top SurfaceIndicator Display on the Control Panel Indicator DescriptionRemote Control Loading Batteries into the Remote Control Open the back coverLoad the batteries Close the back coverInstalling the Projector Precautions for InstallationInstallation Environment Precautions for UsagePrecautions for Ceiling-mount Mounting this UnitInstalling the Projector Projector and Screen InstallationWhen viewed from the left or right When viewed from the top or bottomScreen Size and Projection Distance DLA-HD10KSU/EDLA-HD10KU/E Approximate Projecting DistanceLens Shift Setting Adjust the projection screen positionProject the image on the screen Remove the lens shift coverWhen directing remote control unit toward this unit Effective Range of Remote Control UnitWhen reflecting off a screen Connecting to Various Devices Connecting to DevicesConnecting to Devices Control from external deviceConnecting the Power Cord Supplied Basic Operation Procedures Turning on the powerAdjusting zoom screen size Removing the lens capAdjusting focus Turning off the powerPrecautions During Use Hiding the image temporarilyAdjustments and Settings Using Menus Menu StructureMenu Operation Buttons Button Remote This Unit Function Control UnitAdjustments and Settings Using Menus Procedures for Menu OperationAfter setting is completed, press the Exit button Press the Menu buttonMenu Configuration Power Save Options Menu Menu DisplaySleep Time RC232C bpsPress the Menu button to end Screen MaskingProject image onto the screen Picture Shift Setting About Lamp Replacement OWhen the lamp usage time reaches 2010 hoursReplacing the Lamp Light-source Lamp and Lamp Usage TimeProcedure for Lamp Replacement Insert the lamp unit until it is fully Tighten the screws of the lamp unit and close the handleAttach the lamp cover and fasten the screw Attach the control panel coverTo ensure the lamp time has been reset Resetting Lamp TimeInsert plug into the power outlet Cleaning and Replacing the Filter Pull out the plug from the power outletClean the filter Reinstall the inner filterWhat to do when these messages are displayed Message Cause DetailsActions to be taken upon warning indications About warning indicatorsPlease follow the procedures below Troubleshooting Symptom Probable Cause Corrective Action Reference Remote WorkPin No Signal Name Terminal DescriptionPin Arrangement RS-232C TerminalCommunication Specifications Command FormatHeader Command Parameter RS-232C External ControlExternal control command table Terminal DescriptionSpecifications Specifications Dimensions Unit mm TopFront Bottom SideMemo DLA-HD10KU/E/DLA-HD10KSU/E