eInsert the lamp unit until it is fully in
Handling the Lamp Unit
Do not touch the glass surface of the lamp directly with your hand or stain it. Touching it with a bare hand may dirty the surface, hence shortening the lamp life, causing marked performance deterioration such as darkened screens, lamp blowout as well as malfunction.
fTighten the screws of the lamp unit and close the handle
● Fasten the 2 screws with a F screwdriver.
gAttach the lamp cover and fasten the screw
● Fasten the 1 screw with a F screwdriver.
NOTE:
When fitting the lamp cover, insert the left end (with 2 claws) of the lamp cover into the unit, followed by ensuring that the protruding part on the reverse side of the lamp cover fits snugly into the hole of the unit. As this protrusion acts as a switch, misfitting may lead to failure in turning on the power.
hAttach the control panel cover
Handling the Control Panel Cover
●The gap between this unit and the control panel cover is narrow. Be careful not to stick your finger into the gap between this unit and the control panel cover.
●Be careful of the protrusions and corners of components to avoid injury.
●After attaching the control panel cover, check that the lock is fastened. The control panel cover may drop and cause injury.
Lamp Cover
Control Panel Cover
Fasten the lock on the control panel cover
ENGLISH
37