Luce PT-L6510E, PT-L6600E manual Tv-System, BAL White balance R/G/B, Signal Mode, Standard

Page 31

TV-SYSTEM

(for composite/S-video only)

TV-SYSTEMAUTO1

AUTO2

NTSC

NTSC4.43

PAL

PAL-M

PAL-N

SECAM

AUTO1: Automatically selects the TV standard that matches the input video signal, out of NTSC, PAL, NTSC4.43, and SECAM.

AUTO2: Automatically selects the TV standard that matches the input video signal, out of NTSC, PAL-M, and PAL-N.

Normally “AUTO1” or “AUTO2” should be chosen for this option.

If input video signal quality is poor, choose the TV system that matches the input video signal.

Automatically selected by detecting the horizontal/vertical scan frequencies and colour sub-carrier listed in the table below:

 

H . Scan

V . Scan

Colour

T a b l e

Frequency

Frequency

Subcarrier

 

(kHz)

(Hz)

(MHz)

N T S C

1 5 . 7 5

6 0 . 0 0

3 . 5 8

 

 

 

 

N T S C 4 . 4 3

1 5 . 7 5

6 0 . 0 0

4 . 4 3

 

 

 

P A L

1 5 . 6 3

5 0 . 0 0

 

 

 

 

 

P A L - M

1 5 . 7 5

6 0 . 0 0

3 . 5 8

 

 

 

P A L - N

1 5 . 6 3

5 0 . 0 0

 

 

 

 

 

S E C A M

1 5 . 6 3

5 0 . 0 0

4 . 25 or 4 . 41

 

 

 

 

W.BAL (White balance) R/G/B

(for RGB/DVI signals only)

White balance may be adjusted for each colour to correct reddish or bluish tones in white portions of the picture:

button: Deepens the selected colour. button: Weakens the selected colour.

Note

Separate sets of adjustment parameters can be saved for the RGB1, RGB2 and DVI inputs.

SIGNAL MODE

(for RGB/YPBPR/DVI signals only)

“SIGNAL MODE” displays the names of the signals (resolution) presently applied to the RGB or YPBPR input ports. For details of signal names, see the table on page 48.

If the user mode is registered, the following menu will appear. You can choose either “AUTO” or a registered user setting from “USER1” to “USER3” with the or buttons.

SIGNAL MODE

AUTO

 

 

 

USER1

If “AUTO” is chosen, a setting closest to the user setting is automatically selected. (In the example above, only “USER1” is registered for user address.)

Note

If you choose a user address registered for a signal that does not match the input signal, it is regarded as “no signal”, and the projector will display the specified background colour.

STANDARD

Pressing the “ENTER” button resets all the adjustment parameter values to the factory default values, with a “STANDARD” indicator shown on the upper right corner of the menu.

ENGLISH

31

Image 31
Contents LCD Projector Commercial Use PT-L6600EDear Panasonic Customer Important Safety NoticeLMPORTANT the Moulded Plug U.K. only For Your SAFETY, Please Read the Following Text CarefullyContents Precautions with regard to safety Precautions with regard to safety Do not look into the lens while the projector is being used AccessoriesPower cord plug from the wall outlet Precautions on handlingSystem Example of System upLocation and function of each part Remote ControlProjector Top · Front and Side Projector Top · Rear and Side Rear control panel Location and function of each partInterface panel Loading batteries Using the Remote control unitEffective control range Laser Specifications Using laser pointerSetting projector IDs for remote control Press the ID SET button on remote controlUsing the remote control as a PC mouse Using the Remote control unitUsing the remote control in wired mode Projection Distances Setting-upInstallation Geometry Projection SchemesPin assignments on the RGB2 input port are as follows Setup precautionsExample of connecting with AV products Setting-upColour monitor with RGB video ports Example of connecting with PCsSystem switcher Example of connecting with system switcherStarting to use Powering Up the ProjectorMaking Initial Adjustment Setting input port Powering Off the ProjectorRetracting the Leveling Feet Adjusting the Vertical Position PictureStarting to use Leveling the ProjectorStill image Using the Freeze functionUsing the Shutter function Advice on the installation of exhaust guidesUsing the Digital Zoom D.ZOOM +/- function Menu screens On-screen menusBasic Menu Operations Menu Items SettingReset the Factory Default On-screen menusUsing the Index Window function PT-L6510E only Adjusting the picture Standard Signal ModeTV-SYSTEM BAL White balance R/G/BAdjusting the position Focus What Is S1 Video?Aspect ZoomBack Colour Option 1 settingsRGB Format Lens ShiftLamp Select Option 2 settingsLamp Power Setting Function 1 FuncSetting Unit ID Option 2 settingsRegistering/Deleting Displaying User Mode Using the Serial Connecting to a computer Using the SerialControl command Cable specificationsPin assignment and control Using the remote terminalExample of a control panel layout Indication of lamp monitor Indicator Display Condition Check MeasuresCleaning method Cleaning and replacing the air filterDisplay after 1800 hours Lamp replacement periodReplacing the lamp unit Model No Lamp unit model NoLamp unit replacement steps Replacing the lamp unit Press the Power button to turn off the powerNo image Symptoms ChequesPower does Not turn onSpecifications Remote RGB2 input Audio input For RGB 1/2Video RGB outputAppendix Compatible RGB SignalsTrademark acknowledgments DimensionsTrademark M1002-0