Replacing the lamp unit
Caution!
Replacement of the lamp unit should only be carried out by a qualified technician.
Notes when replacing the lamp unit:
Caution!
Replace the lamp unit only after it has completely cooled off.
•The internal pressure of the light source is high, therefore if it is struck by hard objects or dropped, it may cause damage. Be careful when handling.
•Handle the old lamp unit with care as it is easily broken.
•A Philips screwdriver is necessary when replacing the lamp unit. Be careful not to slip when using the screwdriver.
Caution
• The lamp unit is sold separately. Please consult the service/parts centre at your dealer.
Model No. | Lamp unit model No. | |
|
•Lamps other than those indicated above must not be used with this projector. Be sure to use the specified lamp.
Lamp replacement period
The light source lamp of this projector has a life cycle of 2000 hours (Lamp
Note
• 2,000 hours is a guideline for replacement, not a guarantee time.
• Display after 1800 hours
The lamp monitor indicators (LAMP 1 or LAMP2) will light after the lamp unit runtime has elapsed 1800 hours even during standby mode.
An on - screen message indicating lamp replacement is necessary will be displayed on the screen 30 seconds.
(This
This
| |
REPLACE LAMP | AUTO |
|
|
42