Technicolor - Thomson PT-AE2000E manual Care and Replacement Removing and replacing the lamp unit

Page 45

Care and Replacement

Removing and replacing the lamp unit

1.Use a Phillips screw driver to loosen the 3 lamp unit fixing screws until the screws turn freely.

2.Hold the handle of the lamp unit and release the lamp unit lock.

3.Pull out the lamp unit gently from the projector.

4.Replace the new lamp unit while making sure that the direction of insertion is correct.

Lamp unit fixing screws

Lamp unit lock

Press here

Press here

Press the top of the lamp unit and make sure the unit is installed securely.

5. Tighten the lamp unit fixing screws securely with a Phillips screwdriver.

Attaching the top cover

1.Attach the hinge parts of the top cover to the projector and press slightly until it clicks.

When the projector is mounted in the ceiling, attaching the hinge parts is not required.

2.Hook the top cover safety hook to the projector.

3.Hooking the tabs of the top cover to the front of the projector and lift down slowly.

4.Press the back corner of the top cover gently until it clicks.

Make sure to hook the top cover safety hook to the body.

NOTE:

Be sure to install the lamp unit and the top cover of the projector securely. If they are not securely installed, it may cause the protection circuit to operate so that the power cannot be turned on.

Grip the handle and keep the lamp unit paralleled when you remove the lamp unit. Some parts of the lamp unit are sharpened and may cause injury.

Do not switch the power on while the top cover is opened.

When the projector is mounted in the ceiling, keep the lamp unit paralleled up and remove.

Resetting the LAMP RUNTIME

 

If the lamp usage time has passed 2 000 hours (when LAMP POWER has been set to NORMAL), the

 

projector will switch to standby mode after approximately 10 minutes of operation. The resetting procedure

 

should thus be completed within 10 minutes.

6.

Press and hold the ENTER button for

1.

Connect the mains lead to the projector and a

 

mains socket, and switch the MAIN POWER on.

 

approximately 3 seconds.

2.

Switch the POWER button.

7.

The confirmation screen will be displayed and

3.

Press the MENU button to display the menu.

 

select OK.

4.

Press F G to select OPTION and press ENTER.

8.

Switch off the POWER button to reset the duration

5.

Press F G to select LAMP RUNTIME.

 

of the LAMP RUNTIME.

 

 

 

 

 

 

 

 

9.

Confirm the duration of time in LAMP RUNTIME is

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

reset to "0".

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maintenance

ENGLISH - 45

Image 45
Contents Operating Instructions For business users in the European Union Important Safety NoticeThis Apparatus Must be Earthed To rain or moistureImportant the Moulded Plug U.K. only Important Safety NoticeContents Menu Navigation ContentsPicture menu Lens ControlPrecautions with regard to safety Lamp cover gets very hot, and touching it can cause burns Do not look into the lens while the projector is being usedPrecautions with regard to safety Projector may be subject to electromagnetic interference Accessories Remote control About Your ProjectorLCD Projector body About Your ProjectorTop and front view Computer About Your Projector Back and bottom viewHdmi ComponentCalculation methods for screen dimensions Setting upScreen size and throw distance Projected imageSetting up Front leg adjusters and throwing angleProjection method Mounting in the ceiling and projecting from frontLens shift and positioning Adjusting the lens shift dialsHorizontal shift Vertical shiftWhen the screen position is fixed Setting up Projector location rangeWhen the projector position is fixed 100% 40%Connecting to Component IN/VIDEO IN/S-VIDEO Before connecting to the projectorConnecting to Computer IN/HDMI ConnectionsPower indicator Switching the projector on/offConnecting Disconnecting Projection mode. Recovery may take a whileSwitching on the projector Switching off the projectorSwitching the projector on/off Switch on the connected devices Selecting the input signalAdjust the focus and the projected image size Projecting an imageResetting to the factory default settings Remote control operationOperating range Turning on the button backlightSwitching the aspect ratio Switching the input signalLoading a saved setting Remote control operationAdjusting with luminance options Adjusting the signal condition with a waveformDisplaying the waveform BrightnessSwitching the picture mode Adjusting the focus and zoomAdjusting the image Switching off the projector automaticallyAdjusting the selected colour Setting your own colour profileCreate a new profile Managing stored logsDeleting the saved profiles Saving a log setting as a profileChanging the profile names Loading saved profilesDefault Menu NavigationMain menu and sub-menu Menu Navigation Navigating through the Menu Adjusting with the bar scale itemsDisplaying the main menu Returning to the previous menuPicture menu Split Adjust Colour TemperatureDynamic Iris Waveform MonitorAdjusting the image in a split window Advanced MenuNR Noise Reduction Memory Save Memory LoadXvYCC Deleting a memory setting Signal ModeChanging the name of the memory setting You can edit the named memory settingsPosition menu Clock PhasePosition DOT ClockPosition menu Aspect ratio options and projection example Component signalsZoom FITWSS Auto SetupOver Scan KeystoneBUTTON1/2/3 ZOOM/FOCUSBlank function Press Enter to display the projected imageOption menu Lamp Power InstallationSleep AltitudeManaging the indicated problems Temp and Lamp IndicatorsLamp indicator Temp indicatorCleaning the projector Care and ReplacementWhen to replace the lamp unit Care and ReplacementReplacing the lamp unit Before replacing the lamp unitResetting the Lamp Runtime Care and Replacement Removing and replacing the lamp unitAttaching the top cover Lamp unit fixing screws Lamp unit lock Press hereTroubleshooting Technical Information List of compatible signalsSerial terminal Control commands Technical Information Communication settingsTechnical Information Inquiry commands Installing the safety cable Ceiling mount bracket safeguardsSpecifications Computer VideoComponent HdmiUnit mm DimensionsThese Operating Instructions are printed on recycled paper Trademark acknowledgementsIndex Index S0807-1087B