MATERIAL SAFETY DATA SHEET

Page: 3/4

 

 

 

 

 

Date Revised: Jul. 31. 2002

 

 

 

 

 

Date Issued : Jun. 1. 1998

 

 

 

 

 

MSDS No. F-00831

Personal Protective Equipment

 

 

 

 

Respiratory Protection

: Not required under intended use.

 

Hand Protection

 

: Not required under intended use.

 

Eye Protection

 

: Not required under intended use.

 

Skin Protection

 

: Not required under intended use.

 

Other Protective Equipment

: Use of a dust mask and goggles are recommended when handling a large

 

 

quantity of toner or during long term exposure, as with any non-toxic dust.

 

 

 

9.PHYSICAL AND CHEMICAL PROPERTIES

 

 

Appearance

 

 

 

 

 

Physical State : Solid

Form : Powder

Color : Black

Odor : odorless

Ph

 

: Not applicable

 

 

Boiling / Melting Point

: Not applicable

 

 

Softening Point(°C)

 

: No data

 

 

Flash Point(°C)

 

: Not applicable

 

 

lgnition Point(°C )

 

: No data

 

 

Explosion Properties

: No data

 

 

Density(g/cm³)

 

: 1.1 (bulk density : 0.34)

 

 

Solubility in Water

 

: Negligible

 

 

 

 

 

 

 

10.STABILITY AND REACTIVITY

 

 

 

 

Stability

 

 

: Stable

 

 

Hazardous Reactions

 

: Dust explosion, like most finely divided organic powders.

Conditions to Avoid

 

 

: Electric discharge, throwing into fire.

 

Materials to Avoid

 

 

: Oxidizing Materials

 

 

Hazardous Decomposition Products

: CO, CO2 and NOX

 

 

Further Information

 

 

: None

 

 

 

 

 

 

 

11.TOXICOLOGICAL INFORMATION

 

 

 

 

Acute Toxicity

 

 

 

 

 

Ingestion(oral)

: LD50 > 2000mg/kg (Rats)

 

 

Dermal

: LD50 > 2000mg/kg (Rats)

 

 

Inhalation

: No Data

 

 

 

 

Eye irritation

: Not an irritant

 

 

 

 

Skin irritation

: Not an irritant

 

 

 

 

Skin sensitizer

: No sensitization

 

 

 

Mutagenicity

: Negative (Ames Test)

 

 

Carcinogenicity

: In 1996 the IARC reevaluated carbon black as a Group 2B carcinogen (possible human

 

carcinogen). This

classification is given

to chemicals for

which there is inadequate human

evidence, but sufficient animal evidence on which to base an opinion of carcinogenicity. The classification is based upon the development of lung tumors in rats receiving chronic inhalation exposures to free carbon black at levels that induce particle overload of the lung. Studies performed in animal models other than rats did not show any association between carbon black and lung tumors. Moreover, a two-year cancer bioassay using a typical toner preparation containing carbon black demonstrated no association between toner exposure and tumor development in rats.

Image 81
Contents AL-1552 AL-1553 AL-1555 Class Laser Product Laser Klasse Do not install your unit in areas that are Important points when selecting an installation siteDo not touch the surface green portion of the drum cartridge Trademark acknowledgementsContents Using the Manuals Online manualConventions used in this manual and online manual Part Names Original coverInterface Operation Panel Original to copy key and indicators Two-sided copies fromSetup Procedure Setting UP the UnitPreparing the Unit for Installation Checking Packed Components and AccessoriesLockUnlock Release the scan head locking switchInstalling the TD Cartridge Page Power on Connecting the Power CordPower off methods Initial settings of operation panelAbout the scan head Paper Type of paper Type of media Size Weight FeedingLoading the Paper Tray Gently push the paper tray back into the unit Multi-bypass tray AL-1553, AL-1555 Open the multi-bypass tray and extend the trayPress the tray select key to select the multi-bypass tray Using copy mode Select copy settings before you begin the copy jobUsing printer mode Single bypass AL-1552MFP driver Software for the Sharp Personal MFP SeriesSharpdesk Button ManagerBefore Installation Hardware and Software RequirementsMFP Driver Button Operating Interface Reference pages for how to install Flow of installationInstalling the Software Installing onto Windows XP USB/parallel interfaceDouble-click the setup icon Button Manager installer will start Setup program will start to copy the files Begin installation of the printer driver Begin installation of the scanner driverInstalling onto Windows 98/Me/2000 USB interface Copying files for MFP driver installation You have completed the installation of the software Windows 95/NT Establish the printer settings and click the Next button Setup program will start to copy the files Start indicator Indicators on the Operation PanelOnline indicator Power save indicatorHow to print Using the Printer ModeOpening the printer driver from the start menu Click Printing Preferences button in the General tabPage Using the Scanner Mode Using the Button ManagerSetting up the Button Manager Windows 98/Me/2000 Flow of the Button Manager setting Scan Parameter Settings Dialog BoxScanner AL Event Using the Scanner key to begin scanning Press the Scanner keyApplication Application launched Number Press the start Key Opening the scanner driver and scanning from your computerButton Select Sharp Personal MFP Series, and click the SelectScanning with the Scanner and Camera Wizard in Windows XP Select a name, format, and folder for the scanned imageClick Finish in the screen that appears HOW to USE the Online Manual Installing Acrobat ReaderClick the to read the online manual Using Other Installed Drivers Connecting the Interface Cable Connecting the USB interface cableConnecting the parallel interface cable If you are using the single bypass Select the copy settingsCopy Flow Place the originalOriginal Placement Using the original tableAbout interrupt copying Setting a large original AL-1552 Using the SPF/RSPFOriginal feeder tray Exposure adjustment Exposure ADJUSTMENT/PHOTO CopyingStream feeding mode SET the Copy QuantityAutomatic exposure adjustment Selecting the Tray AL-1553, AL-1555 REDUCTION/ENLARGEMENT/ZOOMSet the reduction/enlargement ratio Press the tray select keyMaking two-sided copies TWO Sided CopyingSelect the copy settings. See SET the Copy Quantity Description of Special Functions Toner Save ModeUser Programs Canceled as desiredDisplaying Total Number of Copies Program Mode ParametersGently pull the TD cartridge out TD Cartridge ReplacementWhile pressing the lock release Lock release buttonGently pull the cartridge out Drum Cartridge ReplacementCabinet Cleaning the UnitTransfer charger Troubleshooting Troubleshooting the UnitIndication Cause and remedy Status IndicatorsPaper feed area. p.66 Misfeed RemovalMisfeed in the paper feed area Misfeed in the fusing areaMisfeed in the transport area Lower the fusing unit release leverOpen the front cover Rotate the feeding roller Direction of the arrowMisfeed in the SPF AL-1553, Rspf AL1555 Misfeed in the lower paper feed area AL-1555AL-1555 Appendix SpecificationsSharp GDI Supply list About Supplies and OptionsInterface cable Parallel interface cableMoving instructions Moving and Storing the UnitProper storage Store the supplies in a location that isIndex Drum replacement required IndicatorMFP driver Index by Purpose Software License Limited Warranty on Media Material Safety Data Sheet Material Safety Data Sheet 3/4 Material Safety Data Sheet 1/4 FIRST-AID Measures Ecological Information Msds No. F-30831 Other Countries outside the EU GREEN-AND-YELLOW