When closing the covers, be sure to close the front cover securely and then close the side cover. If the covers are closed in the wrong order, the covers may be damaged.
D:Misfeed in the lower paper feed area (AL-1555)
1Open the lower side cover (under the manual tray) and
remove the misfed paper. If blinks and the misfed
paper is not seen from the area of the lower side cover, pull out the lower paper tray and remove the misfed paper. Then close the lower paper tray.
2
3
Close the lower side cover.
Close the side cover by pressing the round projections near the side cover open button. The misfeed ( ) indicator will go out and the start () indicator will light up.
E: Misfeed in the SPF (AL-1553), RSPF (AL1555)
An original misfeed may occur at one of three locations: if the misfed original is seen from the original feeder tray, (A) in the original feeder tray; if the misfed original is not seen from the original feeder tray, (B) in the exit area or (C) under the feeding roller. Remove the misfed original following the instructions for each location.
(A)Open the feeding roller cover and pull the original gently to the left and out from the original feeder tray. Close the feeding roller cover. Open and close the SPF/RSPF to clear the SPF/RSPF misfeed ( ) indicator. If the misfed original cannot be easily removed, proceed to (C).
Feeding roller cover
66