Sharp PN-R703, PN-R603 operation manual 25 E

Page 25

Menu Items

COMMUNICATION SETTING

RS-232C/LAN SELECT

Selects the method with which to control the monitor from the computer.

BAUD RATE

Selects the communication speed used for RS-232C communication.

LAN SETUP

Configures the settings to control the monitor from the computer via LAN. (See page 45.)

AUTO ASSIGN FIXED IP ADDR.

Can be enabled when RS-232C/LAN SELECT is LAN and the DHCP CLIENT is OFF.

Set DHCP CLIENT to OFF for the monitor connected to the RS-232C output terminal and the daisy chain of connected monitors that follows. Fixed IP addresses are automatically allocated.

If the IP address is a duplicate with a network device other than a monitor, individually change the IP address.

ID SETTING

ID No. SET

Assigns ID numbers to monitors connected in a daisy chain (see page 34), using the RS-232 cables. The numbers 1 to 255 are available for ID numbers.

If “0” is set, the system regards this as the state where no ID number is set.

AUTO ASSIGN ID No.

ID No. to be used will be automatically assigned when multiple monitors are connected with RS-232C.

Select ON, then press ENTER.

Perform operations using the first monitor in the daisy chain.

COPY SETTING VALUE

When the monitor has been connected to multiple monitors by RS-232C, the settings in the monitor can be copied to the monitor connected to the RS-232C output terminal and to the daisy chain of connected monitors that follows.

Selects the settings to copy with COPY SETTING VALUE TARGET.

“PICTURE” ONLY

Copies the PICTURE menu settings.*

ALL

Copies all the settings.*

Select the ID No. of the monitor that you would like copy to with COPY TO ID No., then select COPY and press ENTER. If you select ALL, settings will be copied to all monitors.

When you would like to confirm the ID No. that is set to the monitor, select ID No. DISPLAY and press ENTER. The ID No. will be displayed on the screen.

* Certain setting details such as ANALOG GAIN, ANALOG OFFSET, and DISPLAY COLOR PATTERN cannot be copied.

25 E

Image 25
Contents PN-R703 PN-R603 A. only Model No Serial NoImportant Information Refer Servicing to Qualified Service PersonnelDear Sharp Customer Safety Precautions Necessary to replace the LED backlight Tips and Safety InstructionsFor the monitor in portrait orientation For the monitor in landscape orientationSupplied Components ContentsNFront view Part NamesNRear view Signal transmitter Part Names NRemote control unitPower button See Mute button See Return button See Size button See11 E Connecting Peripheral EquipmentConnection with a PC or AV equipment Connecting Peripheral Equipment 13 E Connecting the Power CordCable Cable clamp attachment Binding CablesInstalling the batteries Preparing the Remote Control UnitRemote control operation range 15 ETurning on the main power Turning Power On/OffTurning power on/off Main power switchNDate/time setting Disabling power on/off operationsTurning Power On/Off 17 EBasic Operation 19 E Basic Operation NSwitching the screen sizeWide Zoom Normal Dot by DotDisplaying the menu screen Menu ItemsNExample of operation NMenu screen displayMenu item details 21 EMenu Items NSCREEN Menu Items NPICTURE Advanced 23 E3D-Y/C D-SUBVIDEO Display Color PatternMenu Items NAUDIO NSETUP25 E Menu Items NMONITOR Menu Items NMULTI/PIP 27 EMenu Items NOTHERS 29 E NZOOM2 Special SettingNDual screen display Menu Items NEnlargeMenu Items NSCHEDULE PowerDAY of the Week InputNAutomatic adjustment Adjustments for PC screen displayNScreen display for adjustment 31 EAdjustment Lock ALL ResetAdjustment Lock Target Temperature AlertControlling the Monitor with a PC RS-232C Communication procedure33 E PC connectionNID numbers NCommunication intervalWait ← 35 ESetting of the Gamma user data Power control/Input mode selection RS-232C command tableHow to read the command table 37 EPicture menu Controlling the Monitor with a PC RS-232C Screen menuAudio menu 39 EControlling the Monitor with a PC RS-232C Setup menu Controlling the Monitor with a PC RS-232C Monitor menu 41 EControlling the Monitor with a PC RS-232C MULTI/PIP menu Image Position Epos settingLandscape orientation Portrait orientation Others menu 43 EOthers Commands for setting of the Gamma user dataControlling the Monitor with a PC LAN Settings to connect to a LAN45 E To set on the monitorControlling the Monitor with a PC LAN To set from a PC Default Gateway 0.0Controlling with a PC 47 EControlling the Monitor with a PC LAN Basic operationInformation about this monitor appears Standby mode, Power on is the operation available49 E User Name / PasswordDNS Server Address Auto Acquisition DNS ServerLink Mode Installation Information NAME/LOCATIONAuthentication Account Name / PasswordRecipient E-MAIL Addresses 51 ECondition ConfirmationTrap Setting Snmp SettingTrap Setting of Authentication Error Version53 E Troubleshooting 55 E TroubleshootingNProduct Specifications SpecificationsSpecifications NDimensional Drawings57 E Dmpm Digital Monitor Power Management Specifications NPower managementNDDC plug and play NCompatible signal timing AV Specifications NCompatible signal timing PC59 E NRS-232C input terminal pins NPC/AV D-sub input terminal pinsNDisplayPort input terminal pins NDisplayPort output terminal pins NDVI-D output terminal pinsSpecifications NRS-232C output terminal pins 61 EMounting Precautions For Sharp dealers and service engineers PN-R703R603 Mu EN12M1