Controlling the Monitor with a PC
Initialization/Functional Restriction Setting (FUNCTION) menu
Function | Command | Direction | Parameter | Reply |
| Control/Response contents | * |
ALL RESET | RSET | W |
|
| 0: ALL RESET 1, 1: ALL RESET 2 | - | |
ADJUSTMENT LOCK | ALCK | WR |
| 0: OFF, 1:ON1, 2:ON2 |
| ||
ADJUSTMENT LOCK TARGET | ALTG | WR |
| 0: REMOTE CONTROL, 1: MONITOR BUTTONS, 2: BOTH |
| ||
OSD DISPLAY | LOSD | WR |
| 0: ON1, 1: OFF, 2: ON2 |
| ||
LED | OFLD | WR |
| 0: ON, 1: OFF | ○ | ||
TEMPERATURE ALERT | TALT | WR |
| 0: OFF, 1: OSD & LED, 2: LED | |||
POWER BUTTON | PBTN | WR |
| 0: MONITOR, 1: CONTROLLER |
| ||
CONTROLLER INPUT | PCIP | WR |
| 0: |
| ||
|
|
|
|
|
| (”ERR” when MONITOR is selected for POWER BUTTON.) |
|
STATUS ALERT | SALT | WR |
| 0: OFF, 1: OSD & LED, 2: LED |
|
Others
Function | Command | Direction | Parameter | Reply | Control/Response contents | * | ||
|
|
|
|
|
|
|
| |
SCREEN SIZE (PC) |
| WIDE | WR | 1: WIDE, 2: NORMAL, 3: Dot by Dot, 4: ZOOM1, 5: ZOOM2 | ○ | |||
SCREEN SIZE (AV) |
| WIDE | WR | 1: WIDE, 2: ZOOM1, 3: ZOOM2, 4: NORMAL, 5: Dot by Dot | ||||
VOLUME |
| VOLM | WR |
|
| |||
MUTE |
| MUTE | WR | 0: OFF, 1: ON | - | |||
INFORMATION |
| MODEL | INF1 | R |
| Value |
| ● |
|
| SERIAL NO | SRNO | R |
| Value |
| |
|
|
|
|
| ||||
TEMPERATURE SENSOR | DSTA | R |
| 0 | Internal temperature normal |
| ||
|
|
|
|
|
| 1 | Internal temperature abnormal has occurred and the monitor is in standby mode |
|
|
|
|
|
|
| 2 | Internal temperature abnormal occurred (To delete the information of temperature | ● |
|
|
|
|
|
|
| abnormal, turn off the main power.) |
|
|
|
|
|
|
| 3 | Internal temperature abnormal has occurred and backlight brightness is dimmed |
|
|
|
|
|
|
| 4 | Temperature sensor abnormal |
|
Temperature acquisition | ERRT | R |
| Value | Temperature at temperature sensors 1 through 6 are returned in the following |
| ||
|
|
|
|
|
|
| forms: | ○ |
|
|
|
|
|
|
| [Sensor 1], [Sensor 2], [Sensor 3], [Sensor 4], [Sensor 5], [Sensor 6] | |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| Indicates a temperature sensor abnormality when “126” is returned. |
|
CAUSE OF LAST STANDBY MODE | STCA | W | 0 |
| Initialization |
| ||
|
|
|
| R |
| 0 | No detectable error has occurred |
|
|
|
|
|
|
| 1 | Standby mode by POWER button |
|
|
|
|
|
|
| 2 | Main power off by the main power switch | ● |
|
|
|
|
|
| 3 | Standby mode by | |
|
|
|
|
|
| 4 | Input signal waiting mode by No Signal |
|
|
|
|
|
|
| 6 | Standby mode by abnormal temperature |
|
|
|
|
|
|
| 8 | Standby mode by SCHEDULE setting |
|
|
|
|
|
|
| 20 | Standby mode by OFF IF NO OPERATION setting |
|
Commands for setting of the GAMMA user data
Function | Command | Direction | Parameter | Reply | Control/Response contents | * |
|
|
|
|
|
|
|
RED GAMMA DATA TRANSFER | UGRW | W | aaxxxx ··· xxxxcc |
| aa: Block number |
|
GREEN GAMMA DATA TRANSFER | UGGW | W | (xxxx: 32 pieces) |
| xxxx: 32 pieces of user data |
|
|
|
| aa: |
| cc: Checksum (ASCII data) of the block number and user data |
|
BLUE GAMMA DATA TRANSFER | UGBW | W |
|
| ||
xxxx: |
|
|
| |||
|
|
|
|
|
| |
|
|
| cc: |
|
| ○ |
RED GAMMA DATA READ | UGRR | W | xxxx ··· xxxx | xxxx: User data of 32 pieces | ||
GREEN GAMMA DATA READ | UGGR | W | (xxxx: 32 pieces) |
|
| |
|
|
|
| xxxx: |
|
|
BLUE GAMMA DATA READ | UGBR | W |
|
| ||
USER DATA INITIALIZE | UGRS | W | 0 |
| Initialize the user data. |
|
USER DATA SAVE | UGSV | W | 0 |
| Save the user data in the monitor. |
|
E44