Sigma BM-286A service manual Fault Isolation

Page 43

6. TROUBLESHOOTING page 40

6.2. FAULT ISOLATION

When the program is executing on the NT machine there are two small dark green boxes in the lower left hand of the display.

The top box should flash light green every second. This indicates that the DOS machine has sent data to the NT machine.

The bottom box should flash light green upon receiving data from the scale controller. This occurs when the door is closed or once a second when in the Utilities menu, show detector and scale, are being displayed.

If the system fails to operate properly, note all anomalies, and try to determine if or how they are related. This will usually isolate the problem to some degree, and reduce the time required to repair the system. Always perform a thorough visual inspection of the suspect assemblies, looking for loose connectors, pinched and broken wires, burned components, and signs of overheating. If nothing is found during the physical inspection, locate the problem area in the following paragraphs, and isolate the defective assembly using the appropriate procedure.

NOTE:

Always turn the power off when connecting or disconnecting components or cables.

After repairing the system, perform a calibration as outlined in Calibration (section 5.2.).

Model BM-286A

Image 43
Contents Waste Monitor Model BM-286A Theory of Operation Table of ContentsInspection and Installation MaintenanceRecommended Spare Parts Spare Parts Ordering Information TroubleshootingAppendix Warranty Glossary Formulas Configuration Tracking Sheet PartsScope and Purpose of Manual IntroductionSpecifications Introduction Introduction Inspection Installation General Overview Operating InstructionsPOWER-UP and SELF-TESTS Level One Access Access MenuPCA-II Normal Operation Operating Instructions Programming the System Abcdefgh SET-UP MenuOperating Instructions Operating Instructions Waste Stream Parameters Operating Instructions Operating Instructions Operating Instructions This value is used only when the Alarm Type is set to DPM Utilities Menu Operating Instructions Reports Initial Installation Checklist Operating Instructions BM-286A Waste Stream SET-UP Worksheet Unit Operation Theory of Operation Theory of Operation Theory of Operation Theory of Operation Operator Maintenance Maintenance Maintenance LLD Settings for Plastic DetectorsULD Weight Calibration Maintenance Diagnostic Aids Fault Isolation Computers Longs Peak Court LONGMONT, Colorado Appendix B. Glossary Appendix B. Glossary Activity from Counts Reliable Detectable Activity RDA Formula Variance System Modifications Configuration Tracking SheetLongs Peak Court LONGMONT,COLORADO Drawings