Open Problem Reports and Feature Exceptions
PR 100189
On an OS6850, when the MAC address table is full, source learning will not learn MAC addresses dynam- ically and the
Workaround: There is no known workaround at this time.
PR 100614
On an OS6850, when a device is moved from one 802.1x port to another 802.1x port, the device is not classified according to the device classification policy that applies to the new port but is learned on the default VLAN for the new port.
Workaround: Reconfigure the new port by disabling and enabling 802.1x on the port. May also have to reconfigure the device classification policy for the new port as well.
PR 106463
The CLI command “802.1x initialize <slot>/<port>” only applies to the supplicants on the specified port. All the supplicants are forced to authenticate again.
Workaround: There is no known workaround at this time.
Authenticated Switch Access
Problem Reports
PR 91812
On an OS9000, the server information displayed with the show configuration snapshot aaa command or saved with the configuration snapshot aaa <file_name> command contains hashed (encrypted) pass- word/key information. In order for a file created with the latter command to be used for configuring serv- ers, password/key information needs to be edited. AAA expects this information encrypted only at
Workaround: Always edit password/key information before applying a snapshot file.
PR 106557
SNMP MIB walk on aaaAcctCmdTable returns empty even when the table is set.
Workaround: There is no known workaround at this time.
PR 107085
Accounting log for
Workaround: There is no known workaround at this time.