AMX NXI-x000 Series manual Surge damage

Page 12

Introduction

NI-3000 Specifications (Cont.)

Rear Panel Connectors (Cont.):

Relay (Port 8)

Eight-channel single-pole single-throw relay ports

 

• Each relay is independently controlled.

 

• Supports up to 8 independent external relay devices

 

• Channel range = 1-8

 

• Each relay can switch up to 24 VDC or 28 VAC @ 1 A

 

• Two 8-pin 3.5 mm mini-Phoenix (female) connectors provide relay

 

termination

 

 

Digital I/O (Port 17)

Eight-channel binary I/O port for contact closure

 

• Each input is capable of voltage sensing. Input format is software

 

selectable.

 

• Interactive power sensing for IR ports

 

• Channel range = 1-8

 

• All inputs are assigned to respective IR/Serial ports for "automatic" power

 

control through the use of software commands. Power control is provided

 

via commands such as: ’PON’, ’POF’, ’POD’, ’DELAY’, I/O Link etc.).

 

• Contact closure between GND and an I/O port is detected as a PUSH

 

• When used as voltage input - I/O port detects a low signal (0- 1.5 VDC) as

 

a PUSH and a high signal (3.5 - 5 VDC) as a RELEASE

 

• When used as an output - each I/O port acts as a switch to GND and is

 

rated at 200 mA @ 12 VDC

 

10-pin 3.5 mm mini-Phoenix (female) connector provides I/O port

 

termination

 

Note: This IO port uses 5V logic but can handle up to 12V without harm. It

 

can handle up to 12V on the input. At higher voltages you run a higher risk of

 

surge damage.

 

 

IR/Serial (Ports 9-16)

Eight IR/Serial control ports support high-frequency carriers up to

 

1.142 MHz

 

• Each output is capable of three electrical formats: IR, Serial, and Data

 

• Eight IR/Serial data signals can be generated simultaneously.

 

• Channel range = 1-32,767

 

• Channels 1-128 (output): IR commands

 

• Channels 129-253: used as reference channels

 

• Channel 254 (feedback): Power Fail (used with 'PON' and 'POF'

 

commands)

 

• Channel 255 (feedback): Power status (when IO Link is set)

 

• IR ports support data mode (at limited baud rates and wiring distances).

 

• Two 8-pin 3.5 mm mini-Phoenix (female) connectors provide IR/Serial port

 

termination

 

 

Program port

RS-232 DB9 connector (male) can be connected to a DB9 port on a

 

computer; used with serial commands, NetLinx programming commands,

 

other DB9 capable devices, and to upload/download information from the

 

NetLinx Studio 2.4 program.

 

 

Configuration DIP switch

• Sets the communication parameters for the Program port.

 

 

ID pushbutton

• Provides the NetLinx ID (Device only) assignment for the device.

 

• The D notation is used to represent a device number.

 

• Refer to the NetLinx Integrated Controller WebConsole & Programming

 

Guide for details.

 

 

Ethernet port

RJ-45 port for 10/100 Mbps communication. This port automatically

 

negotiates the connection speed (10 Mbps or 100 Mbps) and whether to

 

use half duplex or full duplex mode.

 

 

8

NI-2000, NI-3000, NI-4000 Hardware Reference Guide

Image 12
Contents NXI-x000 Series AMX Limited Warranty and Disclaimer Table of Contents Table of Contents NetLinx Integrated Master Controller Features IntroductionNI-2000 Specifications RearNI-2000 Specifications Rear Panel ConnectorsFront Panel Components Surge damage NI-2000 Specifications NI-3000 Specifications NI-3000 NetLinx Integrated Controller front viewNI-3000 Specifications Surge damage NI-3000 Specifications NI-4000 Specifications NI-4000 NetLinx Integrated Controller front viewNI-4000 Specifications Rear Panel Connectors Guide for details Related Documents Installation and Upgrading Installing NetLinx Control Cards NI-4000 OnlySetting the NetLinx Control Card Addresses NI-4000 Only DevicePortSystem DPSPosition Compact Flash Upgrades Optional Compact Flash UpgradesRemoving NetLinx Control Cards NI-4000 Only Product Name DescriptionInstallation of Compact Flash Upgrades Installing Into An Equipment Rack Closing and Securing the Outer HousingInstall screws Bracket Rack Mounting Holes Setting the Configuration DIP Switch for the Program Port Baud Rate SettingsProgram Run Disable PRD Mode Baud Rate Settings on the Configuration DIP SwitchSetting the CardFrame DIP Switch NI-4000 Only Program Port Connections and WiringWorking With the Configuration DIP Switch Program Port, Pinouts, and SignalsModes and Front Panel LED Blink Patterns Port Assignments and FunctionalityModes and LED Blink Patterns NI-2000 Port AssignmentsWiring Guidelines Wiring length guidelinesWiring Guidelines NI-2000 @ 700 mA Wiring Guidelines NI-3000 & NI-4000 @ 900 mAPreparing Captive Wires Wiring a Power ConnectionUsing the 4-Pin Mini-Phoenix Connector For Data and Power DB9 Device Port Connections and Wiring RS-232 RS-422 RS-485ICSNet Port Connections and Wiring RS-232/422/485 Device Port Wiring SpecificationsICSNet RJ-45 Signals RJ-45 Pinout Information EIA/TIA 568 BICSHub OUT Port Connections and Wiring Relay Port Connections and WiringICSHub OUT Pinouts and Signals Relay ConnectionsInput/Output I/O Port Connections and Wiring Port Wiring Specifications NI-4000 and NI-3000Port Wiring Specifications NI-2000 IR/Serial Port Connections and Wiring NetLinx Control Card Slot Connector NI-4000 onlyIR/Serial Connector Wiring Specifications per Port Signal FunctionEthernet/RJ-45 Port Connections and Wiring Ethernet RJ-45 Pinouts and SignalsPin Signals Connections Pairing Color Ethernet LEDsEthernet Ports Used By the Integrated Controller Ethernet Port DescriptionsPort type Description Standard Port # Page It’s Your World Take Control