AMX NXI-x000 Series manual NI-2000 Specifications, Front Panel Components, Rear Panel Connectors

Page 7

Introduction

NI-2000 Specifications

Dimensions (HWD):

• 3.47" x 17.00" x 3.47" (8.81 cm x 43.18 cm x 8.82 cm)

 

• 2 RU (rack unit) high

 

 

Power Requirement:

• 700 mA @ 12 VDC

 

 

Memory:

• 32 MB SDRAM

 

• 1 MB of Non-volatile Flash

 

 

Compact Flash:

• 32 MB Card (upgradeable). Refer to the Other AMX Equipment section on

 

page 5 for more information.

 

 

Weight:

• 4.50 lbs (2.04 kg)

 

 

Enclosure:

• Metal with black matte finish

 

 

Certifications:

• FCC Part 15 Class B and CE

 

 

Front Panel Components:

 

 

 

LINK/ACT

• Green LED blinks when the Ethernet cable is connected and an active link

 

is established. This LED also blinks when receiving Ethernet data packets.

 

 

Status

• Green LED blinks to indicate that the system is programmed and

 

communicating properly.

 

 

Output

• Red LED blinks when the Controller transmits data, sets channels On/Off,

 

sends data strings, etc.

 

 

Input

• Yellow LED blinks when the Controller receives data from button pushes,

 

strings, commands, channel levels, etc.

 

 

RS-232/422/485 LEDs

Three sets of red and yellow LEDs light to indicate the rear DB9 Ports 1 - 3

 

are transmitting or receiving RS-232, 422, or 485 data:

 

- TX LEDs (red) light when transmitting data

 

- RX LEDs (yellow) light when receiving data

 

- LED activity reflects transmission and reception activity

 

 

Relay LEDs

Four red LEDs light to indicate the rear relay channels 1 - 4 are active

 

(closed).

 

• These LEDs reflect the state of the relay on Port 4

 

• If the relay is engaged = LED On and if the relay is Off = LED Off

 

 

IR/Serial LEDs

Four red LEDs light to indicate the rear IR/Serial channels 1 - 4 are

 

transmitting control data on Ports 5 - 8

 

• LED indictor for each IR port remains lit for the length of time that IR/Serial

 

data is being generated

 

 

I/O LEDs

Four yellow LEDs light when the rear I/O channels 1 - 4 are active

 

• LED indicator for each I/O port reflects the state of that particular port

 

 

Rack-mount brackets

• Provide an installation option for the Integrated Controller to be mounted

 

into an equipment rack, when used with the Installation Kit (KA2105-01).

 

 

Rear Panel Connectors:

 

 

RS-232/422/485 (Ports 1 -3)

Three RS-232/422/485 control ports using DB9 (male) connectors with

 

XON/XOFF (transmit On/transmit Off), CTS/RTS (clear to send/ready to

 

send), and 300-115,200 baud.

 

• Channel range = 1-255

 

• Channels 1-254 provide feedback

 

• Channel 255 (CTS Push channel): Reflects the state of the CTS Input if a

 

'CTSPSH' command was sent to the port

 

• Output data format for each port is selected via software

 

• Three DB9 connectors provide RS-232/422/485 termination

 

 

ICSNet

Two RJ-45 connectors for ICSNet interface

 

 

ICSHub Out

RJ-45 connector provides data to another Hub connected to the Controller

 

 

NI-2000, NI-3000, NI-4000 Hardware Reference Guide

3

 

 

Image 7
Contents NXI-x000 Series AMX Limited Warranty and Disclaimer Table of Contents Table of Contents Introduction NetLinx Integrated Master Controller FeaturesRear NI-2000 SpecificationsRear Panel Connectors NI-2000 SpecificationsFront Panel Components Surge damage NI-2000 Specifications NI-3000 NetLinx Integrated Controller front view NI-3000 SpecificationsNI-3000 Specifications Surge damage NI-3000 Specifications NI-4000 NetLinx Integrated Controller front view NI-4000 SpecificationsNI-4000 Specifications Rear Panel Connectors Guide for details Related Documents Installing NetLinx Control Cards NI-4000 Only Installation and UpgradingDevicePortSystem DPS Setting the NetLinx Control Card Addresses NI-4000 OnlyPosition Product Name Description Compact Flash UpgradesOptional Compact Flash Upgrades Removing NetLinx Control Cards NI-4000 OnlyInstallation of Compact Flash Upgrades Closing and Securing the Outer Housing Installing Into An Equipment RackInstall screws Bracket Rack Mounting Holes Baud Rate Settings on the Configuration DIP Switch Setting the Configuration DIP Switch for the Program PortBaud Rate Settings Program Run Disable PRD ModeProgram Port, Pinouts, and Signals Setting the CardFrame DIP Switch NI-4000 OnlyProgram Port Connections and Wiring Working With the Configuration DIP SwitchNI-2000 Port Assignments Modes and Front Panel LED Blink PatternsPort Assignments and Functionality Modes and LED Blink PatternsWiring Guidelines NI-3000 & NI-4000 @ 900 mA Wiring GuidelinesWiring length guidelines Wiring Guidelines NI-2000 @ 700 mAWiring a Power Connection Preparing Captive WiresUsing the 4-Pin Mini-Phoenix Connector For Data and Power RS-232 RS-422 RS-485 DB9 Device Port Connections and WiringRJ-45 Pinout Information EIA/TIA 568 B ICSNet Port Connections and WiringRS-232/422/485 Device Port Wiring Specifications ICSNet RJ-45 SignalsRelay Connections ICSHub OUT Port Connections and WiringRelay Port Connections and Wiring ICSHub OUT Pinouts and SignalsPort Wiring Specifications NI-4000 and NI-3000 Input/Output I/O Port Connections and WiringPort Wiring Specifications NI-2000 Signal Function IR/Serial Port Connections and WiringNetLinx Control Card Slot Connector NI-4000 only IR/Serial Connector Wiring Specifications per PortEthernet LEDs Ethernet/RJ-45 Port Connections and WiringEthernet RJ-45 Pinouts and Signals Pin Signals Connections Pairing ColorEthernet Port Descriptions Ethernet Ports Used By the Integrated ControllerPort type Description Standard Port # Page It’s Your World Take Control