Introduction

NI-2000 Specifications (Cont.)

Rear Panel Connectors (Cont.):

Ethernet Link/Activity LED

• LEDs show communication activity, connection status, speeds, and mode

 

information:

 

SPD (speed) - Yellow LED lights On when the connection speed is 100

 

Mbps and turns Off when the speed is 10 Mbps.

 

L/A (link/activity) - Green LED lights On when the Ethernet cables are

 

connected/terminated correctly, and blinks when receiving Ethernet data

 

packets.

 

 

AXlink LED

• Green LED indicates the state of the AXlink connector port.

 

• Normal AXlink activity = 1 blink/second

 

• Abnormal AXlink activity = cycle of 3 consecutive blinks and then Off

 

 

AXlink port

4-pin 3.5 mm mini-Phoenix (male) connector provides data and power to

 

external control devices.

 

 

Power port

2-pin 3.5 mm mini-Phoenix (male) connector

 

 

Included Accessories:

2-pin 3.5 mm mini-Phoenix (female) PWR connector (41-5025)

 

4-pin 3.5 mm mini-Phoenix (female) AXlink connector (41-5047)

 

6-pin 3.5 mm mini-Phoenix (female) I/O connector (41-5063)

 

8-pin 3.5 mm mini-Phoenix (female) Relay connector (41-5083)

 

• Installation Kit (KA2105-01):

 

8-pin Relay Common Strip

 

Four rack mount screws

 

Four washers

 

NI-2000 Quick Start Guide

 

• Two CC-NIRC IR Emitters

 

• Two removable rack ears (62-2105-07)

 

 

Other AMX Equipment:

2-pin 3.5 mm mini-Phoenix male connector (41-5026)

 

CC-NIRC IR cables (FG10-000-11)

 

CC-NSER IR/Serial cables (FG10-007-10)

 

• CSB Cable Support Bracket (FG517)

 

• NCK, NetLinx Connector Kit (FG2902)

 

• STS, Serial To Screw Terminal (FG959)

 

• Upgrade Compact Flash (factory programmed with firmware):

 

NXA-CFNI64M - 64 MB compact flash card (FG2116-31)

 

NXA-CFNI128M - 128 MB compact flash card (FG2116-32)

 

NXA-CFNI256M - 256 MB compact flash card (FG2116-33)

 

NXA-CFNI512M - 512 MB compact flash card (FG2116-34)

 

NXA-CFNI1G - 1 GB compact flash card (FG2116-35)

 

 

NI-2000, NI-3000, NI-4000 Hardware Reference Guide

5

 

 

Image 9
Contents NXI-x000 Series AMX Limited Warranty and Disclaimer Table of Contents Table of Contents Introduction NetLinx Integrated Master Controller FeaturesRear NI-2000 SpecificationsNI-2000 Specifications Rear Panel ConnectorsFront Panel Components Surge damage NI-2000 Specifications NI-3000 NetLinx Integrated Controller front view NI-3000 SpecificationsNI-3000 Specifications Surge damage NI-3000 Specifications NI-4000 NetLinx Integrated Controller front view NI-4000 SpecificationsNI-4000 Specifications Rear Panel Connectors Guide for details Related Documents Installing NetLinx Control Cards NI-4000 Only Installation and UpgradingSetting the NetLinx Control Card Addresses NI-4000 Only DevicePortSystem DPSPosition Optional Compact Flash Upgrades Compact Flash UpgradesRemoving NetLinx Control Cards NI-4000 Only Product Name DescriptionInstallation of Compact Flash Upgrades Closing and Securing the Outer Housing Installing Into An Equipment RackInstall screws Bracket Rack Mounting Holes Baud Rate Settings Setting the Configuration DIP Switch for the Program PortProgram Run Disable PRD Mode Baud Rate Settings on the Configuration DIP SwitchProgram Port Connections and Wiring Setting the CardFrame DIP Switch NI-4000 OnlyWorking With the Configuration DIP Switch Program Port, Pinouts, and SignalsPort Assignments and Functionality Modes and Front Panel LED Blink PatternsModes and LED Blink Patterns NI-2000 Port AssignmentsWiring length guidelines Wiring GuidelinesWiring Guidelines NI-2000 @ 700 mA Wiring Guidelines NI-3000 & NI-4000 @ 900 mAPreparing Captive Wires Wiring a Power ConnectionUsing the 4-Pin Mini-Phoenix Connector For Data and Power RS-232 RS-422 RS-485 DB9 Device Port Connections and WiringRS-232/422/485 Device Port Wiring Specifications ICSNet Port Connections and WiringICSNet RJ-45 Signals RJ-45 Pinout Information EIA/TIA 568 BRelay Port Connections and Wiring ICSHub OUT Port Connections and WiringICSHub OUT Pinouts and Signals Relay ConnectionsInput/Output I/O Port Connections and Wiring Port Wiring Specifications NI-4000 and NI-3000Port Wiring Specifications NI-2000 NetLinx Control Card Slot Connector NI-4000 only IR/Serial Port Connections and WiringIR/Serial Connector Wiring Specifications per Port Signal FunctionEthernet RJ-45 Pinouts and Signals Ethernet/RJ-45 Port Connections and WiringPin Signals Connections Pairing Color Ethernet LEDsEthernet Ports Used By the Integrated Controller Ethernet Port DescriptionsPort type Description Standard Port # Page It’s Your World Take Control