APC iSCSI SATA II installation and configuration manual Enclosure Management

Page 61

3.7 Enclosure Management

“Enclosure management” function allows managing enclosure information including “SES config”, “Hardware monitor”, “S.M.A.R.T.” and “UPS” functions. For the enclosure management, there are many sensors for different purposes, such as temperature sensors, voltage sensors, hard disks, fan sensors, power sensors, and LED status. And due to the hardware characteristics are different among these sensors, for different sensors, they have different polling intervals. Below is the detail about polling time intervals:

1.Temperature sensors: 1 minute.

2.Voltage sensors: 1 minute.

3.Hard disk sensors: 10 minutes.

4.Fan sensor: 10 seconds, when there are continuous 3 times of error, controller sends ERROR event log.

5.Power sensor: 10 seconds, when there are continuous 3 times of error, controller sends ERROR event log.

6.LED status: 10 seconds.

[61]

Image 61
Contents ISCSI Sata II RAID Subsystem Table of Contents Advanced Operation Introduction Key Features Technical Specifications Width TerminologyCopy RAID rowScsi Enclosure Services Scsi Accessed Fault- Tolerant EnclosuresMechanism to control access to an iSCSI storage system over ISNS Internet Storage Name ServiceRAID Fundamentals RAID ConceptsDisk Striping Definition of RAID Levels Page Summary RAID Level Description Min. Drives RAID ManagementRAM Volume Relationship DiagramUnpacking the Subsystem Packaging, Shipment and DeliveryIdentifying Parts of the iSCSI RAID Subsystem HDD Status IndicatorFront View Parts FunctionEnvironment Status LEDs LCD Display Panel LCD Control Module LCMRear View Powering On Connecting the iSCSI RAID Subsystem to Your NetworkCarrier Open Button Installing Hard DrivesHBA IP SAN ISCSI IntroductionWeb GUI Management MethodsConsole Serial Port Remote Control Secure ShellLCD Control Module LCM EnclosureRAID System Buzzer Setting Mail setting Æ MailISCSI RAID Subsystem GUI Hierarchy Reboot and Æ Reboot / Shutdown LoginShutdown Sure to logout?Language Status IndicatorsQuick Install System Configuration System Setting IP Address Login Setting Mail Setting Net-SNMPhttp//net-snmp.sourceforge.net Notification SettingPage Entity Property ISCSI ConfigDefault gateway IP settings2 NIC MTU / Jumbo frameNode Session Chap Account Volume Configuration Volume Create Wizard Page Physical Disk It’s done. View the Physical disk PD operations description Vendor Serial Type Write cache StandbyIt’s done. View the RAID group RAID GroupStatus Health RG column description Name TotalGB FreeGBShow RAID group detail information It’s done. View the Virtual disk VD column description Virtual DiskRight Priority Bg rate Status Health RAID #LUN RG name Page Logical Unit Example Select / Volume configuration / RAID group¾ Example Select / Volume configuration / Virtual disk Attach LUN to VD There are 2 methods to attach LUN to VD / Volume configuration / Logical unit Select / Volume configuration / Physical diskHave an error when deleting this RG Enclosure Management SES Configuration Hardware Monitor Hard Drive S.M.A.R.T. Function 4 UPS UPS Type Shutdown Battery Level Shutdown Delay sSystem Information System MaintenanceReset to Default UpgradeConfig Import & Export Event Log Logout Reboot and ShutdownRebuild Advanced OperationRAID 0+1 Way mirrorRG Migration Page VD Extension Support Microsoft Mpio and MC/S Disk RoamingVendor Model Certification ListISCSI Initiator Software Software/Release NumberISCSI HBA card Vendor Model GbE Switch Vendor ModelHard drive Vendor Model PD events Level Type Description Event NotificationsHW events Level Type Description š EMS events Level Type Descriptionš LVM3 events Level Type Description š RMS events Level Type DescriptionVD migration VD name completes migration Finished š iSCSI events Level Type Description š Battery backup events Level Type Descriptionš Jbod events Level Type Description š System maintenance events Level Type Description Known IssuesClick Discovery Microsoft iSCSI InitiatorClick Targets Page Click Details Introduction Installation Steps for Large Volume Over 2TBPage Page Mpio and MC/S Setup Instructions Click Mpio tab, select Load Balance Policy to Round Robin Enable Enable multi-path checkbox. Then click Advanced…Choose Round Robin in Load Balance Policy System information ISCSI RAID Subsystem