| imported. |
INFO | RG restored | Configuration of RG <name> has been |
|
| restored. |
INFO | VD restored | Configuration of VD <name> has been |
|
| restored. |
iSCSI events
Level | Type | Description |
|
|
|
INFO | iSCSI login | iSCSI login from <IP> succeeds. |
| succeeds |
|
INFO | iSCSI login | iSCSI login from <IP> was rejected, |
| rejected | reason [<string>] |
INFO | iSCSI logout | iSCSI logout from <IP> was received, |
|
| reason [<string>]. |
Battery backup events
Level | Type | Description |
|
|
|
INFO | BBM sync data | Abnormal shutdown detected, start |
|
| flushing |
|
| (<number> KB). |
INFO | BBM sync data | Abnormal shutdown detected, flushing |
|
| |
INFO | BBM detected | Battery backup module is detected. |
INFO | BBM is good | Battery backup module is good. |
INFO | BBM is | Battery backup module is charging. |
| charging |
|
WARNING | BBM is failed | Battery backup module is failed. |
INFO | BBM | Battery backup feature is <item>. |
JBOD events
Level | Type | Description |
|
|
|
INFO | Disk inserted | JBOD <number> disk <slot> is inserted |
|
| into system. |
Warning | Disk removed | JBOD <number> disk <slot> is removed |
|
| from system. |
ERROR | HDD failure | JBOD <number> disk <slot> is disabled. |
INFO | JBOD inserted | JBOD <number> is inserted into system |
WARNING | JBOD removed | JBOD <number> is removed from system |
WARNING | SMART T.E.C | JBOD <number> disk <slot>: S.M.A.R.T. |
|
| Threshold Exceed Condition occurred for |
|
| attribute %s |
WARNING | SMART Failure | JBOD <number> disk <slot>: Failure to |
|
| get S.M.A.R.T information |
INFO | Dedicated | JBOD <number> PD <slot> has been |
| spare | configured to RG <name> as a dedicated |
| configured | spare disk. |
INFO | Global spare | JBOD <number> PD <slot>d has been |
| configured | configured as a global spare disk. |
WARNING | PD read error | Read error occurred at LBA <address>- |
[83]