APC iSCSI SATA II š iSCSI events Level Type Description, š Jbod events Level Type Description

Page 83

 

 

imported.

INFO

RG restored

Configuration of RG <name> has been

 

 

restored.

INFO

VD restored

Configuration of VD <name> has been

 

 

restored.

šiSCSI events

Level

Type

Description

 

 

 

INFO

iSCSI login

iSCSI login from <IP> succeeds.

 

succeeds

 

INFO

iSCSI login

iSCSI login from <IP> was rejected,

 

rejected

reason [<string>]

INFO

iSCSI logout

iSCSI logout from <IP> was received,

 

 

reason [<string>].

šBattery backup events

Level

Type

Description

 

 

 

INFO

BBM sync data

Abnormal shutdown detected, start

 

 

flushing battery-backuped data

 

 

(<number> KB).

INFO

BBM sync data

Abnormal shutdown detected, flushing

 

 

battery-backuped data finishes.

INFO

BBM detected

Battery backup module is detected.

INFO

BBM is good

Battery backup module is good.

INFO

BBM is

Battery backup module is charging.

 

charging

 

WARNING

BBM is failed

Battery backup module is failed.

INFO

BBM

Battery backup feature is <item>.

šJBOD events

Level

Type

Description

 

 

 

INFO

Disk inserted

JBOD <number> disk <slot> is inserted

 

 

into system.

Warning

Disk removed

JBOD <number> disk <slot> is removed

 

 

from system.

ERROR

HDD failure

JBOD <number> disk <slot> is disabled.

INFO

JBOD inserted

JBOD <number> is inserted into system

WARNING

JBOD removed

JBOD <number> is removed from system

WARNING

SMART T.E.C

JBOD <number> disk <slot>: S.M.A.R.T.

 

 

Threshold Exceed Condition occurred for

 

 

attribute %s

WARNING

SMART Failure

JBOD <number> disk <slot>: Failure to

 

 

get S.M.A.R.T information

INFO

Dedicated

JBOD <number> PD <slot> has been

 

spare

configured to RG <name> as a dedicated

 

configured

spare disk.

INFO

Global spare

JBOD <number> PD <slot>d has been

 

configured

configured as a global spare disk.

WARNING

PD read error

Read error occurred at LBA <address>-

[83]

Image 83
Contents ISCSI Sata II RAID Subsystem Table of Contents Advanced Operation Introduction Key Features Technical Specifications RAID row TerminologyWidth CopyISNS Internet Storage Name Service Scsi Accessed Fault- Tolerant EnclosuresScsi Enclosure Services Mechanism to control access to an iSCSI storage system overDisk Striping RAID ConceptsRAID Fundamentals Definition of RAID Levels Page Summary RAID Level Description Min. Drives RAID ManagementRAM Volume Relationship DiagramUnpacking the Subsystem Packaging, Shipment and DeliveryParts Function HDD Status IndicatorIdentifying Parts of the iSCSI RAID Subsystem Front ViewEnvironment Status LEDs LCD Display Panel LCD Control Module LCMRear View Powering On Connecting the iSCSI RAID Subsystem to Your NetworkCarrier Open Button Installing Hard DrivesHBA IP SAN ISCSI IntroductionWeb GUI Management MethodsConsole Serial Port Remote Control Secure ShellLCD Control Module LCM EnclosureRAID System Buzzer ISCSI RAID Subsystem GUI Hierarchy Mail setting Æ MailSetting Sure to logout? LoginReboot and Æ Reboot / Shutdown ShutdownLanguage Status IndicatorsQuick Install System Configuration System Setting IP Address Login Setting Mail Setting Net-SNMPhttp//net-snmp.sourceforge.net Notification SettingPage Entity Property ISCSI ConfigMTU / Jumbo frame IP settingsDefault gateway 2 NICNode Session Chap Account Volume Configuration Volume Create Wizard Page Physical Disk It’s done. View the Physical disk PD operations description Vendor Serial Type Write cache StandbyIt’s done. View the RAID group RAID GroupStatus Health RG column description Name TotalGB FreeGBShow RAID group detail information It’s done. View the Virtual disk VD column description Virtual DiskRight Priority Bg rate Status Health RAID #LUN RG name Page Logical Unit ¾ Example Select / Volume configuration / RAID groupExample Select / Volume configuration / Virtual disk Attach LUN to VD There are 2 methods to attach LUN to VD / Volume configuration / Logical unit Select / Volume configuration / Physical diskHave an error when deleting this RG Enclosure Management SES Configuration Hardware Monitor Hard Drive S.M.A.R.T. Function 4 UPS UPS Type Shutdown Battery Level Shutdown Delay sSystem Information System MaintenanceReset to Default UpgradeConfig Import & Export Event Log Logout Reboot and ShutdownRebuild Advanced OperationRAID 0+1 Way mirrorRG Migration Page VD Extension Support Microsoft Mpio and MC/S Disk RoamingSoftware/Release Number Certification ListVendor Model ISCSI Initiator SoftwareISCSI HBA card Vendor Model GbE Switch Vendor ModelHard drive Vendor Model š EMS events Level Type Description Event NotificationsPD events Level Type Description HW events Level Type Descriptionš LVM3 events Level Type Description š RMS events Level Type DescriptionVD migration VD name completes migration Finished š Jbod events Level Type Description š Battery backup events Level Type Descriptionš iSCSI events Level Type Description š System maintenance events Level Type Description Known IssuesClick Discovery Microsoft iSCSI InitiatorClick Targets Page Click Details Introduction Installation Steps for Large Volume Over 2TBPage Page Mpio and MC/S Setup Instructions System information ISCSI RAID Subsystem Enable Enable multi-path checkbox. Then click Advanced…Click Mpio tab, select Load Balance Policy to Round Robin Choose Round Robin in Load Balance Policy