APC iSCSI SATA II Certification List, Vendor Model, ISCSI Initiator Software

Page 77

Appendix

A. Certification List

RAM

RAM Spec: 184pins, DDR333(PC2700), Reg.(register) or UB(Unbufferred), ECC or Non-ECC, from 64MB to 1GB, 32-bit or 64-bit data bus width, x8 or x16 devices, 9 to 11 bits column address.

 

Vendor

 

Model

 

 

 

 

ATP

AG64L72T8SQC4S, 512MB DDR-400 (ECC) with Samsung

 

ATP

AG28L64T8SHC4S, 1GB DDR-400 with Samsung

 

ATP

AG28L72T8SHC4S, 1GB DDR-400 (ECC) with Samsung

 

ATP

AB28L72Q8SHC4S, 1GB DDR-400 (ECC, Reg.) with

 

 

Samsung

 

Unigen

UG732D6688KN-DH, 256MB DDR-333 (Unbufferred) with

 

 

Hynix

 

Unigen

UG732D7588KZ-DH, 256MB DDR-333 (ECC, Reg.) with

 

 

Elpida

 

Unigen

UG764D7588KZ-DH, 512MB DDR-333 (ECC, Reg.) with

 

 

Elpida

 

Unigen

UG7128D7588LZ-DH, 1GB DDR-333 (ECC, Reg.) with Hynix

 

Unigen

UG7128D7488LN-GJF, 1GB DDR-400 (ECC) with Hynix

 

Unigen

UG7128D7588LZ-GJF, 1GB DDR-400 (ECC, Reg.) with

 

 

Hynix

 

Unigen

UG7128D7588LZ-GJF, 1GB DDR-400 (ECC, Reg.) with

 

 

Elpida

 

Unigen

UG732D6688KS-DH, 256MB DDR-333 (Unbufferred, Low

 

 

profile) with Hynix

 

Unigen

UG764D6688LS-DH, 512MB DDR-333 (Unbufferred, Low

 

 

profile) with Hynix

 

Unigen

UG718D6688LN-GJF, 1GB DDR-400 with Hynix

 

Unigen

UG718D6688LN-GJF, 1GB DDR-400 with Elpida

iSCSI Initiator (Software)

 

 

 

 

 

OS

 

Software/Release Number

 

 

 

 

Microsoft

Microsoft iSCSI Software Initiator Release v2.07

 

Windows

System Requirements:

 

 

 

 

1. Windows 2000 Server with SP4

 

 

2. Windows Server 2003 with SP2

 

 

3. Windows Server 2003 R2 with SP2

 

 

4.

Windows Server 2008

 

Linux

The iSCSI Initiators are different for different Linux Kernels.

 

 

1. For Red Hat Enterprise Linux 3 (Kernel 2.4), install

 

 

 

linux-iscsi-3.6.3.tar

 

 

2.

For Red Hat Enterprise Linux 4 (Kernel 2.6), use the

 

 

 

[77]

Image 77
Contents ISCSI Sata II RAID Subsystem Table of Contents Advanced Operation Introduction Key Features Technical Specifications Width TerminologyCopy RAID rowScsi Enclosure Services Scsi Accessed Fault- Tolerant EnclosuresMechanism to control access to an iSCSI storage system over ISNS Internet Storage Name ServiceDisk Striping RAID ConceptsRAID Fundamentals Definition of RAID Levels Page Summary RAID Level Description Min. Drives RAID ManagementRAM Volume Relationship DiagramUnpacking the Subsystem Packaging, Shipment and DeliveryIdentifying Parts of the iSCSI RAID Subsystem HDD Status IndicatorFront View Parts FunctionEnvironment Status LEDs LCD Display Panel LCD Control Module LCMRear View Powering On Connecting the iSCSI RAID Subsystem to Your NetworkCarrier Open Button Installing Hard DrivesHBA IP SAN ISCSI IntroductionWeb GUI Management MethodsConsole Serial Port Remote Control Secure ShellLCD Control Module LCM EnclosureRAID System Buzzer ISCSI RAID Subsystem GUI Hierarchy Mail setting Æ MailSetting Reboot and Æ Reboot / Shutdown LoginShutdown Sure to logout?Language Status IndicatorsQuick Install System Configuration System Setting IP Address Login Setting Mail Setting Net-SNMPhttp//net-snmp.sourceforge.net Notification SettingPage Entity Property ISCSI ConfigDefault gateway IP settings2 NIC MTU / Jumbo frameNode Session Chap Account Volume Configuration Volume Create Wizard Page Physical Disk It’s done. View the Physical disk PD operations description Vendor Serial Type Write cache StandbyIt’s done. View the RAID group RAID GroupStatus Health RG column description Name TotalGB FreeGBShow RAID group detail information It’s done. View the Virtual disk VD column description Virtual DiskRight Priority Bg rate Status Health RAID #LUN RG name Page Logical Unit ¾ Example Select / Volume configuration / RAID groupExample Select / Volume configuration / Virtual disk Attach LUN to VD There are 2 methods to attach LUN to VD / Volume configuration / Logical unit Select / Volume configuration / Physical diskHave an error when deleting this RG Enclosure Management SES Configuration Hardware Monitor Hard Drive S.M.A.R.T. Function 4 UPS UPS Type Shutdown Battery Level Shutdown Delay sSystem Information System MaintenanceReset to Default UpgradeConfig Import & Export Event Log Logout Reboot and ShutdownRebuild Advanced OperationRAID 0+1 Way mirrorRG Migration Page VD Extension Support Microsoft Mpio and MC/S Disk RoamingVendor Model Certification ListISCSI Initiator Software Software/Release NumberISCSI HBA card Vendor Model GbE Switch Vendor ModelHard drive Vendor Model PD events Level Type Description Event NotificationsHW events Level Type Description š EMS events Level Type Descriptionš LVM3 events Level Type Description š RMS events Level Type DescriptionVD migration VD name completes migration Finished š Jbod events Level Type Description š Battery backup events Level Type Descriptionš iSCSI events Level Type Description š System maintenance events Level Type Description Known IssuesClick Discovery Microsoft iSCSI InitiatorClick Targets Page Click Details Introduction Installation Steps for Large Volume Over 2TBPage Page Mpio and MC/S Setup Instructions Click Mpio tab, select Load Balance Policy to Round Robin Enable Enable multi-path checkbox. Then click Advanced…Choose Round Robin in Load Balance Policy System information ISCSI RAID Subsystem