APC iSCSI SATA II Identifying Parts of the iSCSI RAID Subsystem, Front View, HDD Status Indicator

Page 16

2.3 Identifying Parts of the iSCSI RAID Subsystem

The illustrations below identify the various parts of the subsystem.

2.3.1 Front View

3

2

1

4

5

6

7

 

 

 

 

1Carrier Open Button Use this to open the disk tray. Press the button to open. This button also shows the Lock Indicator.

When the Lock Groove is horizontal, this indicates that the Drive Tray is locked. When the Lock Groove is vertical, the Drive Tray is unlocked. Lock and unlock the Drive Trays by using a flat-head screw driver.

2Tray Lever – Use this to pull out the disk tray.

3HDD Status Indicator

Every Drive Tray contains two LEDs for displaying the HDD status.

Parts

Function

HDD Status

Green LED indicates power is on and hard drive status

LED

is good for this slot. Red LED indicates no hard drive.

 

 

HDD Access

LED will blink blue when the hard drive is being

LED

accessed.

 

 

4Activity LED – This LED will be blinking Blue when the controller is busy or data is being accessed.

[16]

Image 16
Contents ISCSI Sata II RAID Subsystem Table of Contents Advanced Operation Introduction Key Features Technical Specifications Terminology WidthCopy RAID rowScsi Accessed Fault- Tolerant Enclosures Scsi Enclosure ServicesMechanism to control access to an iSCSI storage system over ISNS Internet Storage Name ServiceRAID Fundamentals RAID ConceptsDisk Striping Definition of RAID Levels Page Summary RAID Management RAID Level Description Min. DrivesVolume Relationship Diagram RAMPackaging, Shipment and Delivery Unpacking the SubsystemHDD Status Indicator Identifying Parts of the iSCSI RAID SubsystemFront View Parts FunctionLCD Display Panel LCD Control Module LCM Environment Status LEDsRear View Connecting the iSCSI RAID Subsystem to Your Network Powering OnInstalling Hard Drives Carrier Open ButtonISCSI Introduction HBA IP SANManagement Methods Web GUIRemote Control Secure Shell Console Serial PortEnclosure LCD Control Module LCMRAID System Buzzer Setting Mail setting Æ MailISCSI RAID Subsystem GUI Hierarchy Login Reboot and Æ Reboot / ShutdownShutdown Sure to logout?Status Indicators LanguageQuick Install System Configuration System Setting IP Address Login Setting Mail Setting Notification Setting Net-SNMPhttp//net-snmp.sourceforge.netPage ISCSI Config Entity PropertyIP settings Default gateway2 NIC MTU / Jumbo frameNode Session Chap Account Volume Configuration Volume Create Wizard Page Physical Disk It’s done. View the Physical disk Vendor Serial Type Write cache Standby PD operations descriptionRAID Group It’s done. View the RAID groupRG column description Name TotalGB FreeGB Status HealthShow RAID group detail information Virtual Disk It’s done. View the Virtual disk VD column descriptionRight Priority Bg rate Status Health RAID #LUN RG name Page Logical Unit Example Select / Volume configuration / RAID group¾ Example Select / Volume configuration / Virtual disk Attach LUN to VD There are 2 methods to attach LUN to VD Select / Volume configuration / Physical disk / Volume configuration / Logical unitHave an error when deleting this RG Enclosure Management SES Configuration Hardware Monitor Hard Drive S.M.A.R.T. Function UPS Type Shutdown Battery Level Shutdown Delay s 4 UPSSystem Maintenance System InformationUpgrade Reset to DefaultConfig Import & Export Event Log Reboot and Shutdown LogoutAdvanced Operation RebuildWay mirror RAID 0+1RG Migration Page VD Extension Disk Roaming Support Microsoft Mpio and MC/SCertification List Vendor ModelISCSI Initiator Software Software/Release NumberGbE Switch Vendor Model ISCSI HBA card Vendor ModelHard drive Vendor Model Event Notifications PD events Level Type DescriptionHW events Level Type Description š EMS events Level Type Descriptionš RMS events Level Type Description š LVM3 events Level Type DescriptionVD migration VD name completes migration Finished š iSCSI events Level Type Description š Battery backup events Level Type Descriptionš Jbod events Level Type Description Known Issues š System maintenance events Level Type DescriptionMicrosoft iSCSI Initiator Click DiscoveryClick Targets Page Click Details Installation Steps for Large Volume Over 2TB IntroductionPage Page Mpio and MC/S Setup Instructions Enable Enable multi-path checkbox. Then click Advanced… Click Mpio tab, select Load Balance Policy to Round RobinChoose Round Robin in Load Balance Policy System information ISCSI RAID Subsystem