APC iSCSI SATA II installation and configuration manual Technical Specifications

Page 6

1.2 Technical Specifications

Form Factor

 

 

1U 19-inch rackmount chassis

 

 

 

 

 

RAID processor

 

Instant RAID volume availability and

Intel XScale IOP331

 

background initialization support

 

 

 

RAID Level

 

Supports over 2TB per volume

0, 1, 0+1, 3, 5, 6, 10 and JBOD

 

 

 

 

 

 

Cache memory

 

Online consistency check

512MB ~ 1GB DDR333 DIMM supported

 

 

 

No. of channels (host and drives)

Bad block auto-remapping

2 and 4

 

 

 

 

 

 

 

 

 

 

Host

bus

interface 1Gb/s

Ethernet

S.M.A.R.T. support

 

 

 

 

 

Drive

bus

interface 3Gb/s

SATA II

New disk insertion / removal detection

 

 

 

Hot-swap drive trays

 

Auto volume rebuild

Four (4) 1-inch trays

 

 

 

Host access control

 

Array roaming

Read-Write & Read-Only

 

 

 

 

 

 

Supports CHAP authentication

 

Audible alarm

 

 

 

Jumbo frame support

 

Password protection

 

 

 

Global hot spare disks

 

UPS connection

 

 

 

 

 

Maximum logical volume: up to 255

Power supplies: 220W power supply

w/PFC

 

 

 

 

Maximum host connectionup to 32

Cooling fans1

 

 

 

 

 

Maximum host clustering

 

Power requirements

 

AC 90V ~ 264V full range

up to 8 for one logical volume

 

 

6A ~ 3A, 50Hz ~ 60Hz

 

 

 

 

 

 

 

 

Environmental

Online Volume migration

 

Relative Humidity

 

 

 

 

10% ~ 85% Non-condensing

Online Volume expansion

 

Operating Temp

 

10oC ~ 40oC (50oF ~ 104oF)

Configurable stripe size

 

Physical Dimensions

 

44(H) x 446.4(W) x 506(D)mm

 

 

 

 

 

 

 

 

 

[6]

Image 6
Contents ISCSI Sata II RAID Subsystem Table of Contents Advanced Operation Introduction Key Features Technical Specifications Copy TerminologyWidth RAID rowMechanism to control access to an iSCSI storage system over Scsi Accessed Fault- Tolerant EnclosuresScsi Enclosure Services ISNS Internet Storage Name ServiceRAID Concepts RAID FundamentalsDisk Striping Definition of RAID Levels Page Summary RAID Management RAID Level Description Min. DrivesVolume Relationship Diagram RAMPackaging, Shipment and Delivery Unpacking the SubsystemFront View HDD Status IndicatorIdentifying Parts of the iSCSI RAID Subsystem Parts FunctionLCD Display Panel LCD Control Module LCM Environment Status LEDsRear View Connecting the iSCSI RAID Subsystem to Your Network Powering OnInstalling Hard Drives Carrier Open ButtonISCSI Introduction HBA IP SANManagement Methods Web GUIRemote Control Secure Shell Console Serial PortEnclosure LCD Control Module LCMRAID System Buzzer Mail setting Æ Mail SettingISCSI RAID Subsystem GUI Hierarchy Shutdown LoginReboot and Æ Reboot / Shutdown Sure to logout?Status Indicators LanguageQuick Install System Configuration System Setting IP Address Login Setting Mail Setting Notification Setting Net-SNMPhttp//net-snmp.sourceforge.netPage ISCSI Config Entity Property2 NIC IP settingsDefault gateway MTU / Jumbo frameNode Session Chap Account Volume Configuration Volume Create Wizard Page Physical Disk It’s done. View the Physical disk Vendor Serial Type Write cache Standby PD operations descriptionRAID Group It’s done. View the RAID groupRG column description Name TotalGB FreeGB Status HealthShow RAID group detail information Virtual Disk It’s done. View the Virtual disk VD column descriptionRight Priority Bg rate Status Health RAID #LUN RG name Page Logical Unit Select / Volume configuration / RAID group Example¾ Example Select / Volume configuration / Virtual disk Attach LUN to VD There are 2 methods to attach LUN to VD Select / Volume configuration / Physical disk / Volume configuration / Logical unitHave an error when deleting this RG Enclosure Management SES Configuration Hardware Monitor Hard Drive S.M.A.R.T. Function UPS Type Shutdown Battery Level Shutdown Delay s 4 UPSSystem Maintenance System InformationUpgrade Reset to DefaultConfig Import & Export Event Log Reboot and Shutdown LogoutAdvanced Operation RebuildWay mirror RAID 0+1RG Migration Page VD Extension Disk Roaming Support Microsoft Mpio and MC/SISCSI Initiator Software Certification ListVendor Model Software/Release NumberGbE Switch Vendor Model ISCSI HBA card Vendor ModelHard drive Vendor Model HW events Level Type Description Event NotificationsPD events Level Type Description š EMS events Level Type Descriptionš RMS events Level Type Description š LVM3 events Level Type DescriptionVD migration VD name completes migration Finished š Battery backup events Level Type Description š iSCSI events Level Type Descriptionš Jbod events Level Type Description Known Issues š System maintenance events Level Type DescriptionMicrosoft iSCSI Initiator Click DiscoveryClick Targets Page Click Details Installation Steps for Large Volume Over 2TB IntroductionPage Page Mpio and MC/S Setup Instructions Choose Round Robin in Load Balance Policy Enable Enable multi-path checkbox. Then click Advanced…Click Mpio tab, select Load Balance Policy to Round Robin System information ISCSI RAID Subsystem