RuggedCom WIN7000 manual WiN7000 Wall Mounting Diagram

Page 19

3.Installation Procedures

3.Lift the base station by the eye bolts and secure it to the mounting bracket. At the top of the unit and mounting bracket, use NC 1/4" × 1/2" hex screws (Item 8) and NC 1/4" flat washers (Item 9). At the bottom of the unit and mounting bracket, use 5/16" flat washers (Item 6), 5/16" spring washers (Item 7), and NC 5/16" × 1/2" screws (Item 13).

4.Complete the wiring connections.

Seal all connectors with self-fusing electrical tape or insulating putty suitable for use in the unit’s installation environment

3.4.3. Wall Mounting

Figure 3.3. WiN7000 Wall Mounting Diagram

Item

Quantity

Description

1

1

Mounting brackets

 

 

 

2

1

WiN7000

 

 

 

3

4

Screw NC 1/4" × 1/2" hex

 

 

 

4

4

Washer flat NC 1/4"

 

 

 

5

4

Washer spring NC 1/4"

 

 

 

6

2

Bolt NC 1/4"

 

 

 

7

4

Screw 5/16" hex cap × 2"

 

 

 

8

4

Washer flat 5/16"

 

 

 

9

4

Washer spring 5/16"

 

 

 

10

4

Dowel 5/16"

 

 

 

11

1

Mounting upper bracket

 

 

 

Table 3.2. WiN7000 Wall Mount Parts List

RuggedCom® RuggedMAX WiN7000

19

Installation Guide Rev1

Image 19
Contents RuggedMAX WiN7000 Registered Trademarks Warranty Contacting RuggedComAll Rights Reserved Disclaimer Of LiabilityTable of Contents List of Figures List of Tables FCC Statement And Cautions About this Guide IntroductionCapabilities and Features Power Supply Requirements Safety InformationGeneral Introduction Lightning Protection Equipment InstallationPower Cord Protection Radio Frequency RF ExposureOutdoor Grounding System User ports and power supplySafety Hazards Antenna Grounding RequirementsWin7000 Dimensions WiN7000 Physical SpecificationsMounting Considerations Site and Installation RequirementsPackage Components and Unpacking Installation ProceduresPre-Installation Safety Instructions Installation ToolsInstalling the WiN7000 Mounting Bracket WiN7000 Mounting BracketPole Mounting Procedure 3.1. Installing the WiN7000 on a PoleWall Mounting WiN7000 Wall Mounting DiagramTower Mount Procedure 3.2. Installing the WiN7000 on a WallCable Connections Copper Ethernet Port Option Weatherproofing Procedure 3.3. Weatherproofing Cable ConnectorsWeatherproofing Cable Connections Wrapping the Connector with Electrical Tape Copper and SFA Type Base Station Power ConnectionsSFD Type Base Station 11. Positive 48V ConfigurationConnecting the WiN7000 to the Web Interface SetupProcedure 4.1. Connecting a computer to the base station RuggedMAX Web Interface General Status No IP connectivity TroubleshootingNo Serial Connection Power and Ethernet Cable Pinouts Appendix A. Connector and Cable PinoutsConsole Cable Pinouts Figure A.2. WiN7000 Console Connector PinoutAppendix B. WiN7000 Specifications Radio SafetyEnvironmental 1613 & IEC61850-3Acronym Description Appendix C. List of AcronymsRuggedCom Inc Appendix D. Warranty