3Com 2426-PWR, 2226-SFP, 2250-SFP manual 3Com Corporation 350 Campus Drive Marlborough MA

Page 2

3Com Corporation 350 Campus Drive Marlborough MA 01752-3064

Copyright © 2008, 3Com Corporation. All rights reserved. No part of this documentation may be reproduced in any form or by any means or used to make any derivative work (such as translation, transformation, or adaptation) without written permission from 3Com Corporation.

3Com Corporation reserves the right to revise this documentation and to make changes in content from time to time without obligation on the part of 3Com Corporation to provide notification of such revision or change.

3Com Corporation provides this documentation without warranty, term, or condition of any kind, either implied or expressed, including, but not limited to, the implied warranties, terms or conditions of merchantability, satisfactory quality, and fitness for a particular purpose. 3Com may make improvements or changes in the product(s) and/or the program(s) described in this documentation at any time.

If there is any software on removable media described in this documentation, it is furnished under a license agreement included with the product as a separate document, in the hard copy documentation, or on the removable media in a directory file named LICENSE.TXT or !LICENSE.TXT. If you are unable to locate a copy, please contact 3Com and a copy will be provided to you.

UNITED STATES GOVERNMENT LEGEND

If you are a United States government agency, then this documentation and the software described herein are provided to you subject to the following:

All technical data and computer software are commercial in nature and developed solely at private expense. Software is delivered as “Commercial Computer Software” as defined in DFARS 252.227-7014 (June 1995) or as a “commercial item” as defined in FAR 2.101(a) and as such is provided with only such rights as are provided in 3Com’s standard commercial license for the Software. Technical data is provided with limited rights only as provided in DFAR 252.227-7015 (Nov 1995) or FAR 52.227-14 (June 1987), whichever is applicable. You agree not to remove or deface any portion of any legend provided on any licensed program or documentation contained in, or delivered to you in conjunction with, this User Guide.

Unless otherwise indicated, 3Com registered trademarks are registered in the United States and may or may not be registered in other countries.

3Com and the 3Com logo are registered trademarks of 3Com Corporation.

Intel and Pentium are registered trademarks of Intel Corporation. Microsoft, MS-DOS, Windows, and Windows NT are registered trademarks of Microsoft Corporation. Novell and NetWare are registered trademarks of Novell, Inc. UNIX is a registered trademark in the United States and other countries, licensed exclusively through X/Open Company, Ltd.

IEEE and 802 are registered trademarks of the Institute of Electrical and Electronics Engineers, Inc.

All other company and product names may be trademarks of the respective companies with which they are associated.

ENVIRONMENTAL STATEMENT

It is the policy of 3Com Corporation to be environmentally friendly in all operations. To uphold our policy, we are committed to:

Establishing environmental performance standards that comply with national legislation and regulations.

Conserving energy, materials and natural resources in all operations.

Reducing the waste generated by all operations. Ensuring that all waste conforms to recognized environmental standards. Maximizing the recyclable and reusable content of all products.

Ensuring that all products can be recycled, reused and disposed of safely.

Ensuring that all products are labelled according to recognized environmental standards.

Improving our environmental record on a continual basis.

End of Life Statement

3Com processes allow for the recovery, reclamation and safe disposal of all end-of-life electronic components.

Regulated Materials Statement

3Com products do not contain any hazardous or ozone-depleting material.

Environmental Statement about the Documentation

The documentation for this product is printed on paper that comes from sustainable, managed forests; it is fully biodegradable and recyclable, and is completely chlorine-free. The varnish is environmentally friendly, and the inks are vegetable-based with a low heavy-metal content.

Image 2
Contents Installation and User Guide 3Com Corporation 350 Campus Drive Marlborough MA Contents Snmp 3COM CLI Reference Guide Page About this Guide ConventionsDocumentation Comments Product RegistrationAutosensing of MDI/MDIX Connections Overview of the Baseline SwitchFeatures and Capabilities Autonegotiating 10/100 Mbps PortsGigabit Combo Ports RJ-45/SFP Physical FeaturesPower-over-Ethernet Capability Front Panel RJ-45 10/100 PortsGigabit Combo Ports RJ-45/SFP 10/100BASE-TX Link/Activity Status LEDs SFP Mode Power LED Rear PanelPackage Contents Installing the Switch Important Safety InformationPositioning the Switch Importante Avviso di SicurezzaUsing the Mounting Kit Rack-Mounting or Free-StandingPlacing Units On Top of Each Other Supplying Power to the SwitchMontagesatz Anweisungen Checking for Correct Operation Status MeaningInserting an SFP Transceiver Using SFP TranceiversApproved SFP Transceivers Performing Spot Checks Removing an SFP TransceiverRefer to Troubleshooting on Requirements for Accessing the Web Interface Using the Console Command Line Interface CLICLI Summary with Default IP Address Logging On to the Web Interface CLI Summary with Assigned IP AddressNavigating the Web Interface MenuMenu Item Description Snmp Buttons Port StatusRunning the 3Com Switch Detect Application 3Com Switch Detect Welcome Screen3Com Switch Detect Search Screen Connecting to the WEB Interface Configuration Overview Device Summary InformationDevice View Polling IntervalAutomatic IP Configuration Administration SettingsModifying the IP Address Settings Color KeyIP Setup Backup ConfigurationRestore Configuration Firmware UpgradeReboot ResetSystem Access Initialize, keep IP settingUser Summary Create UserModify User Remove UserSystem Time SetupSystem Name Snmp Remove Configuring VLANsSnmp Add Vlan Setup Screen Modify VlanModify Port RenameRemove Port DetailVlan Detail Sample Vlan ConfigurationsForwarding Tagged/Untagged Frames Setting Up Two VLANs on the Same Switch Setting Up Vlan Across Two SwitchesTagged Vlan Configuration Spanning TreeSummary Spanning Tree Summary ScreenPort Setup Spanning Tree Setup ScreenSpanning Tree Port Setup Screen Igmp Snooping & QueryBroadcast Storm Broadcast Storm Summary ScreenQoS VoIP Traffic Settings ModifyQoS VoIP Setup Screen OUI Summary OUI AddPoE 3CBLSF26-PWR only QoS OUI Modify ScreenConfiguring Port Settings AdministrationPort Administration Summary Screen DetailPort Administration Setup Screen Speed/Duplex for 1000 Mbps ConnectionsLink Aggregation Guidelines for Creating TrunksCreate Link Aggregation Summary ScreenUse the Remove tab to delete a link aggregation group Radius Client SecurityStatistics 802.1X Settings Configure802.1X Summary Screen Monitoring Address TablePort Mirroring Port SummaryUse the Setup tab to create a port mirror session Cable Diagnostics Cable Diagnostic Summary ScreenDiagnostics Cable Diagnostic ScreenConfiguring the Switch from the WEB Interface Troubleshooting Resetting to Factory DefaultsFiber cable is connected, but the Module Active LED is off Solving LED IssuesForgotten Static IP Address All ports appear to show continual activity If the Problem PersistsLink/Activity LED is on, but network performance is poor Troubleshooting Register Your Product Purchase Value-Added ServicesTroubleshoot Online Access Software Downloads Telephone Technical Support and Repair Contact UsCountry Telephone Number Latsupportanc@3com.com Physical 3CBLSF26 Related StandardsEnvironmental Electrical3CBLSF26PWR Related Standards Physical 3CBLSF50 Related StandardsEnvironmental ElectricalAppendix B Technical Information PIN-OUTS Console CableModem Cable Null Modem CablePC-AT Serial Cable Ethernet Port RJ-45 Pin Assignments Pin Number 10/100 1000Appendix C PIN-OUTS Logging on to the CLI Getting Started with the Command Line InterfaceConsole Port Concurrent CLI Sessions CLI CommandsAutomatic Logout Syntax Default Configuration Ping ParametersIpSetup 255.255.255.0Upgrade Following example resets the Switch to factory defaults InitializePassword LogoutRegulatory Notices 100 Bandwidth 1000BASE-TAuto-negotiation Category 5e Cables Category 3 CablesCategory 5 Cables Category 6 CablesIeee 802.1D Full DuplexHalf Duplex Ieee 802.1QLink Aggregation Power over EthernetLayer MAC AddressSubnet Address SwitchServer Subnet MaskVlan Index NumbersIndex