About the Adaptec 44300 Controller

The Adaptec 44300 is a low-profile PCI-X to 4-Phy SAS 1.0 HostRAID controller with these features:

Internal SAS Connector

 

J3 (Aggregate Activity LED Header)

Mounting bracket

3.3V PCI-X Connector

 

Form factor

Low-profile

Bus compatibility

PCI-X

PCI bus width (max)

64-bit

PCI bus speed (max)

133 MHz

PHYs

4

Connectors, internal

1 x4 internal SFF-8484

 

SAS 1.1 connector

RAID levels

0, 1, 10

Simple Volume

Yes

Disk drives

SAS (3.0Gbps), SATA I (1.5Gbps),

 

SATA II (3.0Gbps)

Maximum number of disk drives

4 direct-attached drives or up to 128

 

using expanded technology

Hot spares

Yes

Enclosure support

Yes

Native Command Queuing (NCQ)

No

Automatic failover

Yes

Audible alarm

No

Note: There is no separate I2C connector. See the HostRAID Controller LED and I2C Connector Reference on page 87 for details.

Image 19
Contents SAS and Sata HostRAID Controller Copyright Adaptec Customer Support Limited 3-Year Hardware Warranty Regulatory Compliance Statements Contents Getting Started Managing Your Storage Space Using the ARC Utility Safety Information What You Need to Know Before You Begin About This GuideConventions Used in This Guide How to Find More InformationWhat You Need to Know Before You Begin Terminology Used in this GuideAbout This Guide l About Your HostRAID Controller Array Level Features HostRAID Controller FeaturesAbout Your HostRAID Controller l PCI-X About the Adaptec 58300 ControllerAbout the Adaptec 48300 Controller About the Adaptec 44300 Controller About the Adaptec 1430SA Controller About the Adaptec 1420SA Controller About the Adaptec 1220SA Controller About the Adaptec 1225SA Controller Kit Contents and System Requirements System Requirements Kit ContentsInstalling the HostRAID Controller Disk Drives Before You Begin Installing the HostRAID ControllerSelecting SAS Cables Selecting Disk DrivesInstalling the HostRAID Controller and Disk Drives l Selecting Sata Cables Connecting Disk Drives to SAS HostRAID ControllersConnecting to a Backplane Connecting Directly to the HostRAID ControllerInstalling the SAS HostRAID Controller to a SAS Expander Connecting Disk Drives to Sata HostRAID ControllersChecking Your Controller and Devices Setting the Boot Controller Next Steps Getting Started Choosing a RAID Level Choosing Installation OptionsBasic Installation Steps Installing with an Operating SystemInstalling on an Existing Operating System Creating a Bootable Array Creating an Array with the ACU Creating an ArrayCreating an Array with Adaptec Storage Manager Select Express configuration..., then click Next Making Your Array BootableInstalling the Driver and an Operating System Creating a Driver Disk Installing with WindowsInstalling with Suse Linux Installing with Red Hat LinuxInstalling with NetWare Installing the Driver on an Existing Operating System Creating a Driver Disk or an Array Installing on Windows XP or WindowsInstalling on Red Hat or Suse Linux Installing on Windows VistaInstalling on NetWare Continue with Managing Your Storage Space on Managing Your Storage Space Installing Adaptec Storage Manager About the Hrconf Command Line UtilityAbout Adaptec Storage Manager About the Adaptec Flash Utility About the ARC UtilityWhich Utility Should I Use? Solving Problems Failed Disk Drive Not Protected by a Hot Spare Troubleshooting ChecklistRecovering from a Disk Drive Failure Failed Disk Drive Protected by a Hot SpareMultiple Failures in the Same Array Resetting the ControllerFailure in Multiple Arrays Simultaneously Disk Drive Failure in a RAID 0 ArraySolving Problems l Understanding RAID Stripe-Unit Size RAID Technology OverviewRAID 0 Non-RAID Arrays Understanding Drive SegmentsRAID 10 Arrays RAID 1 ArraysSelecting the Best RAID Level Introduction to SAS Terminology Used in This Appendix What is SAS?What’s a Phy? How Do SAS Devices Communicate?What’s a SAS Port? How are Disk Drives Identified in SAS? What’s a SAS Connector?What’s a SAS Address? What do SAS Cables Look Like?SAS Expander Connections What are the SAS Connection Options?Direct-Attach Connections Backplane ConnectionsSAS Domain How is SAS Different from Parallel SCSI?Parallel Scsi Serial Attached Scsi Using the ARC Utility Creating a New Array Introduction to the ARC UtilityRunning the ARC Utility Creating and Managing ArraysQuick Init Creating a RAID 0 on new drives Rebuilding Arrays Managing ArraysViewing Array Properties Deleting Arrays Adding/Deleting Hot SparesEnabling/Disabling Write Cache Atapi Support Using SerialSelectManaging Bootable Arrays and Devices Configuring Disk DrivesDevice SerialSelect OptionsPHY Configuration Using SATASelectSATASelect Options Formatting and Verifying Disk DrivesIdentifying Disk Drives Locating Disk DrivesViewing the Event Log DOS Using the Adaptec Flash Utility forCompatibility Information IntroductionObtaining the Firmware Creating the Firmware Kit On Floppy Disks Running the AFURunning the Menu-Based AFU Running the AFU from the Command Line AFU CommandsExamples Command Switches Command SyntaxExample Update \ AFU Verify /C Updating Flash Using AFU Command LineTo update a single HostRAID controller HostRAID Controller LED and I2C Connector Reference Adaptec 48300 Activity LED Connector Specification Adaptec 58300 Activity LED Connector SpecificationAdaptec 1430SA Activity LED and I2C Connector Specification Adaptec 44300 Activity LED Connector SpecificationLedsum Adaptec 1420SA Activity LED and I2C Connector SpecificationAdaptec 1225SA Activity LED Specification Adaptec 1220SA Activity LED Connector SpecificationElectrostatic DischargeESD Safety InformationTechnical Specifications DC Power Requirements Environmental SpecificationsCurrent Requirements Glossary Build ConfigureConfigured array Consistency check commandEvent Fault-tolerant arrayDisk ID Drive LEDLow-level format Native Command QueuingLegacy disk Logical deviceRebuild RAID volumeSimple volume RAID signatureTask VolumeStripe size Striped arrayACU IndexSATASelect SerialSelect utilities SATASelect Adaptec, Inc

1430SA, 1225SA, 1420SA, 1220SA, 48300 specifications

Adaptec, a prominent name in the world of storage solutions, offers a diverse array of RAID controller cards aimed at enhancing data storage and management in both consumer and enterprise markets. Among its acclaimed products are the Adaptec 1220SA, 1430SA, 44300, 1225SA, and 1420SA. These cards ensure increased data protection, improved performance, and greater scalability.

The Adaptec 1220SA is a robust SATA RAID controller designed for small to medium-sized businesses. It supports RAID levels 0, 1, 1E, 5, and 10, providing flexibility for users to optimize data redundancy and performance. With the capability of handling up to four SATA drives, it guarantees an efficient and reliable setup while minimizing potential data loss. The controller also features an intuitive web-based management interface, making it easier to administer and configure.

The Adaptec 1430SA extends similar functionality with enhanced features. It is designed to accommodate up to eight SATA drives and supports the latest 3 Gbps SATA technology. This model includes optional battery backup for preserving critical data during unexpected power outages, ensuring that users maintain data integrity and protection at all times.

In the enterprise domain, the Adaptec 44300 shines as a high-performance RAID controller. It offers support for 12 SATA drives, which allows for expansive storage scalability, crucial for data-intensive applications. The advanced RAID features include support for RAID 6, providing dual parity data protection. The controller is built with a powerful processor and memory, allowing for faster data processing and enhanced throughput.

The Adaptec 1225SA is another noteworthy model. Designed for entry-level RAID applications, it offers a balanced combination of performance and reliability. Supporting up to four SATA drives, the 1225SA is particularly well-suited for environments where uptime is critical, delivering functionalities such as hot-swapping. This feature allows users to replace failed drives without shutting down the system, significantly reducing downtime.

Lastly, the Adaptec 1420SA caters to users who require a cost-effective but reliable storage solution. With support for RAID 0, 1, and JBOD, it is a versatile option for enthusiasts and small businesses. The controller can manage up to two SATA drives, making it ideal for basic applications where simplicity and efficiency are paramount.

Collectively, these Adaptec controllers showcase cutting-edge RAID technology and storage management features, reinforcing their position as reliable options for users ranging from home users to enterprise-level organizations seeking optimal data storage solutions.