Adaptec 1420SA, 58300, 44300, 48300, 1220SA, 1225SA, 1430SA manual Kit Contents, System Requirements

Page 25

Chapter 3: Kit Contents and System Requirements l 25

Kit Contents

Adaptec SAS or SATA HostRAID controllers

These utilities are embedded in the controller’s BIOS :

Array Configuration Utility (ACU)—Used to create, configure, and manage arrays

SerialSelect or SATASelect—Used to modify your controller and disk drive settings

Disk Utilities—Used to format and verify disk drives

HostRAID installation CD (bootable), including controller drivers, and this Guide

Adaptec Storage Manager installation CD (not bootable), including Adaptec Storage Manager and the Adaptec HRCONF (HostRAID Configuration) command line utility

Readme files

Cables (type and quantity vary depending on your HostRAID controller—not included in all controller kits. See Chapter 5 for details.)

Low-profile bracket

SAS and SATA HostRAID Controllers Quickstart Guide

System Requirements

PC-compatible computer with Intel Pentium, or equivalent processor

A motherboard with these features:

Complies with the PCI Local Bus Specification, Revision 2.2 and higher

Supports multifunction devices where one of the devices is a PCI bridge

Large memory-mapped address ranges

Note: Refer to the Readme file on the HostRAID Installation CD for additional motherboard compatibility information.

One of these operating systems:

Microsoft® Windows® Server 2003, XP and Windows Vista

Red Hat Linux

SUSE Linux

Novell® NetWare®

Note: For up-to-date operating system version support, visit www.adaptec.com.

At least 256 MB of RAMs

Available compatible PCI/PCI-X/PCIe slot (depending on your controller model—see Chapter 2.)

40 MB of free drive space

16-bit SVGA color monitor with a resolution of at least 800 x 600

CD drive

Appropriate interface cables

Image 25
Contents SAS and Sata HostRAID Controller Copyright Adaptec Customer Support Limited 3-Year Hardware Warranty Regulatory Compliance Statements Contents Getting Started Managing Your Storage Space Using the ARC Utility Safety Information What You Need to Know Before You Begin About This GuideWhat You Need to Know Before You Begin How to Find More InformationTerminology Used in this Guide Conventions Used in This GuideAbout This Guide l About Your HostRAID Controller Array Level Features HostRAID Controller FeaturesAbout Your HostRAID Controller l PCI-X About the Adaptec 58300 ControllerAbout the Adaptec 48300 Controller About the Adaptec 44300 Controller About the Adaptec 1430SA Controller About the Adaptec 1420SA Controller About the Adaptec 1220SA Controller About the Adaptec 1225SA Controller Kit Contents and System Requirements System Requirements Kit ContentsInstalling the HostRAID Controller Disk Drives Before You Begin Installing the HostRAID ControllerSelecting SAS Cables Selecting Disk DrivesInstalling the HostRAID Controller and Disk Drives l Selecting Sata Cables Connecting Disk Drives to SAS HostRAID ControllersConnecting to a Backplane Connecting Directly to the HostRAID ControllerInstalling the SAS HostRAID Controller to a SAS Expander Connecting Disk Drives to Sata HostRAID ControllersChecking Your Controller and Devices Setting the Boot Controller Next Steps Getting Started Basic Installation Steps Choosing Installation OptionsInstalling with an Operating System Choosing a RAID LevelInstalling on an Existing Operating System Creating a Bootable Array Creating an Array with the ACU Creating an ArrayCreating an Array with Adaptec Storage Manager Select Express configuration..., then click Next Making Your Array BootableInstalling the Driver and an Operating System Creating a Driver Disk Installing with WindowsInstalling with Suse Linux Installing with Red Hat LinuxInstalling with NetWare Installing the Driver on an Existing Operating System Creating a Driver Disk or an Array Installing on Windows XP or WindowsInstalling on Red Hat or Suse Linux Installing on Windows VistaInstalling on NetWare Continue with Managing Your Storage Space on Managing Your Storage Space Installing Adaptec Storage Manager About the Hrconf Command Line UtilityAbout Adaptec Storage Manager About the Adaptec Flash Utility About the ARC UtilityWhich Utility Should I Use? Solving Problems Recovering from a Disk Drive Failure Troubleshooting ChecklistFailed Disk Drive Protected by a Hot Spare Failed Disk Drive Not Protected by a Hot SpareFailure in Multiple Arrays Simultaneously Resetting the ControllerDisk Drive Failure in a RAID 0 Array Multiple Failures in the Same ArraySolving Problems l Understanding RAID RAID 0 Non-RAID Arrays RAID Technology OverviewUnderstanding Drive Segments Stripe-Unit SizeRAID 10 Arrays RAID 1 ArraysSelecting the Best RAID Level Introduction to SAS Terminology Used in This Appendix What is SAS?What’s a Phy? How Do SAS Devices Communicate?What’s a SAS Port? What’s a SAS Address? What’s a SAS Connector?What do SAS Cables Look Like? How are Disk Drives Identified in SAS?Direct-Attach Connections What are the SAS Connection Options?Backplane Connections SAS Expander ConnectionsSAS Domain How is SAS Different from Parallel SCSI?Parallel Scsi Serial Attached Scsi Using the ARC Utility Running the ARC Utility Introduction to the ARC UtilityCreating and Managing Arrays Creating a New ArrayQuick Init Creating a RAID 0 on new drives Rebuilding Arrays Managing ArraysViewing Array Properties Deleting Arrays Adding/Deleting Hot SparesEnabling/Disabling Write Cache Managing Bootable Arrays and Devices Using SerialSelectConfiguring Disk Drives Atapi SupportDevice SerialSelect OptionsPHY Configuration Using SATASelectSATASelect Options Formatting and Verifying Disk DrivesIdentifying Disk Drives Locating Disk DrivesViewing the Event Log DOS Using the Adaptec Flash Utility forCompatibility Information IntroductionObtaining the Firmware Creating the Firmware Kit On Floppy Disks Running the AFURunning the Menu-Based AFU Running the AFU from the Command Line AFU CommandsExamples Command Switches Command SyntaxExample Update \ AFU Verify /C Updating Flash Using AFU Command LineTo update a single HostRAID controller HostRAID Controller LED and I2C Connector Reference Adaptec 48300 Activity LED Connector Specification Adaptec 58300 Activity LED Connector SpecificationAdaptec 1430SA Activity LED and I2C Connector Specification Adaptec 44300 Activity LED Connector SpecificationLedsum Adaptec 1420SA Activity LED and I2C Connector SpecificationAdaptec 1225SA Activity LED Specification Adaptec 1220SA Activity LED Connector SpecificationElectrostatic DischargeESD Safety InformationTechnical Specifications DC Power Requirements Environmental SpecificationsCurrent Requirements Glossary Configured array ConfigureConsistency check command BuildDisk ID Fault-tolerant arrayDrive LED EventLegacy disk Native Command QueuingLogical device Low-level formatSimple volume RAID volumeRAID signature RebuildStripe size VolumeStriped array TaskACU IndexSATASelect SerialSelect utilities SATASelect Adaptec, Inc

1430SA, 1225SA, 1420SA, 1220SA, 48300 specifications

Adaptec, a prominent name in the world of storage solutions, offers a diverse array of RAID controller cards aimed at enhancing data storage and management in both consumer and enterprise markets. Among its acclaimed products are the Adaptec 1220SA, 1430SA, 44300, 1225SA, and 1420SA. These cards ensure increased data protection, improved performance, and greater scalability.

The Adaptec 1220SA is a robust SATA RAID controller designed for small to medium-sized businesses. It supports RAID levels 0, 1, 1E, 5, and 10, providing flexibility for users to optimize data redundancy and performance. With the capability of handling up to four SATA drives, it guarantees an efficient and reliable setup while minimizing potential data loss. The controller also features an intuitive web-based management interface, making it easier to administer and configure.

The Adaptec 1430SA extends similar functionality with enhanced features. It is designed to accommodate up to eight SATA drives and supports the latest 3 Gbps SATA technology. This model includes optional battery backup for preserving critical data during unexpected power outages, ensuring that users maintain data integrity and protection at all times.

In the enterprise domain, the Adaptec 44300 shines as a high-performance RAID controller. It offers support for 12 SATA drives, which allows for expansive storage scalability, crucial for data-intensive applications. The advanced RAID features include support for RAID 6, providing dual parity data protection. The controller is built with a powerful processor and memory, allowing for faster data processing and enhanced throughput.

The Adaptec 1225SA is another noteworthy model. Designed for entry-level RAID applications, it offers a balanced combination of performance and reliability. Supporting up to four SATA drives, the 1225SA is particularly well-suited for environments where uptime is critical, delivering functionalities such as hot-swapping. This feature allows users to replace failed drives without shutting down the system, significantly reducing downtime.

Lastly, the Adaptec 1420SA caters to users who require a cost-effective but reliable storage solution. With support for RAID 0, 1, and JBOD, it is a versatile option for enthusiasts and small businesses. The controller can manage up to two SATA drives, making it ideal for basic applications where simplicity and efficiency are paramount.

Collectively, these Adaptec controllers showcase cutting-edge RAID technology and storage management features, reinforcing their position as reliable options for users ranging from home users to enterprise-level organizations seeking optimal data storage solutions.