Adaptec 1430SA, 58300, 44300, 48300, 1220SA, 1420SA, 1225SA manual Contents

Page 6

 

Contents

1 About This Guide

 

What You Need to Know Before You Begin

12

Terminology Used in this Guide

12

Conventions Used in This Guide

12

How to Find More Information

12

2 About Your HostRAID Controller

 

HostRAID Controller Features

15

Array Level Features

15

About the Adaptec 58300 Controller

17

About the Adaptec 48300 Controller

18

About the Adaptec 44300 Controller

19

About the Adaptec 1430SA Controller

20

About the Adaptec 1420SA Controller

21

About the Adaptec 1220SA Controller

22

About the Adaptec 1225SA Controller

23

3 Kit Contents and System Requirements

 

Kit Contents

25

System Requirements

25

4 Installing the HostRAID Controller and Disk Drives

 

Before You Begin

27

Installing the HostRAID Controller

27

Selecting Disk Drives

28

Selecting SAS Cables

28

Image 6
Contents SAS and Sata HostRAID Controller Copyright Adaptec Customer Support Limited 3-Year Hardware Warranty Regulatory Compliance Statements Contents Getting Started Managing Your Storage Space Using the ARC Utility Safety Information About This Guide What You Need to Know Before You BeginTerminology Used in this Guide How to Find More InformationWhat You Need to Know Before You Begin Conventions Used in This GuideAbout This Guide l About Your HostRAID Controller HostRAID Controller Features Array Level FeaturesAbout Your HostRAID Controller l About the Adaptec 58300 Controller PCI-XAbout the Adaptec 48300 Controller About the Adaptec 44300 Controller About the Adaptec 1430SA Controller About the Adaptec 1420SA Controller About the Adaptec 1220SA Controller About the Adaptec 1225SA Controller Kit Contents and System Requirements Kit Contents System RequirementsInstalling the HostRAID Controller Disk Drives Installing the HostRAID Controller Before You BeginSelecting Disk Drives Selecting SAS CablesInstalling the HostRAID Controller and Disk Drives l Connecting Disk Drives to SAS HostRAID Controllers Selecting Sata CablesConnecting Directly to the HostRAID Controller Connecting to a BackplaneConnecting Disk Drives to Sata HostRAID Controllers Installing the SAS HostRAID Controller to a SAS ExpanderChecking Your Controller and Devices Setting the Boot Controller Next Steps Getting Started Installing with an Operating System Choosing Installation OptionsBasic Installation Steps Choosing a RAID LevelInstalling on an Existing Operating System Creating a Bootable Array Creating an Array Creating an Array with the ACUCreating an Array with Adaptec Storage Manager Making Your Array Bootable Select Express configuration..., then click NextInstalling the Driver and an Operating System Installing with Windows Creating a Driver DiskInstalling with Red Hat Linux Installing with Suse LinuxInstalling with NetWare Installing the Driver on an Existing Operating System Installing on Windows XP or Windows Creating a Driver Disk or an ArrayInstalling on Windows Vista Installing on Red Hat or Suse LinuxInstalling on NetWare Continue with Managing Your Storage Space on Managing Your Storage Space About the Hrconf Command Line Utility Installing Adaptec Storage ManagerAbout Adaptec Storage Manager About the ARC Utility About the Adaptec Flash UtilityWhich Utility Should I Use? Solving Problems Failed Disk Drive Protected by a Hot Spare Troubleshooting ChecklistRecovering from a Disk Drive Failure Failed Disk Drive Not Protected by a Hot SpareDisk Drive Failure in a RAID 0 Array Resetting the ControllerFailure in Multiple Arrays Simultaneously Multiple Failures in the Same ArraySolving Problems l Understanding RAID Understanding Drive Segments RAID Technology OverviewRAID 0 Non-RAID Arrays Stripe-Unit SizeRAID 1 Arrays RAID 10 ArraysSelecting the Best RAID Level Introduction to SAS What is SAS? Terminology Used in This AppendixHow Do SAS Devices Communicate? What’s a Phy?What’s a SAS Port? What do SAS Cables Look Like? What’s a SAS Connector?What’s a SAS Address? How are Disk Drives Identified in SAS?Backplane Connections What are the SAS Connection Options?Direct-Attach Connections SAS Expander ConnectionsHow is SAS Different from Parallel SCSI? SAS DomainParallel Scsi Serial Attached Scsi Using the ARC Utility Creating and Managing Arrays Introduction to the ARC UtilityRunning the ARC Utility Creating a New ArrayQuick Init Creating a RAID 0 on new drives Managing Arrays Rebuilding ArraysViewing Array Properties Adding/Deleting Hot Spares Deleting ArraysEnabling/Disabling Write Cache Configuring Disk Drives Using SerialSelectManaging Bootable Arrays and Devices Atapi SupportSerialSelect Options DeviceUsing SATASelect PHY ConfigurationFormatting and Verifying Disk Drives SATASelect OptionsLocating Disk Drives Identifying Disk DrivesViewing the Event Log Using the Adaptec Flash Utility for DOSIntroduction Compatibility InformationObtaining the Firmware Running the AFU Creating the Firmware Kit On Floppy DisksRunning the Menu-Based AFU AFU Commands Running the AFU from the Command LineExamples Command Syntax Command SwitchesExample Update Updating Flash Using AFU Command Line \ AFU Verify /CTo update a single HostRAID controller HostRAID Controller LED and I2C Connector Reference Adaptec 58300 Activity LED Connector Specification Adaptec 48300 Activity LED Connector SpecificationAdaptec 44300 Activity LED Connector Specification Adaptec 1430SA Activity LED and I2C Connector SpecificationAdaptec 1420SA Activity LED and I2C Connector Specification LedsumAdaptec 1220SA Activity LED Connector Specification Adaptec 1225SA Activity LED SpecificationSafety Information Electrostatic DischargeESDTechnical Specifications Environmental Specifications DC Power RequirementsCurrent Requirements Glossary Consistency check command ConfigureConfigured array BuildDrive LED Fault-tolerant arrayDisk ID EventLogical device Native Command QueuingLegacy disk Low-level formatRAID signature RAID volumeSimple volume RebuildStriped array VolumeStripe size TaskIndex ACUSATASelect SerialSelect utilities SATASelect Adaptec, Inc

1430SA, 1225SA, 1420SA, 1220SA, 48300 specifications

Adaptec, a prominent name in the world of storage solutions, offers a diverse array of RAID controller cards aimed at enhancing data storage and management in both consumer and enterprise markets. Among its acclaimed products are the Adaptec 1220SA, 1430SA, 44300, 1225SA, and 1420SA. These cards ensure increased data protection, improved performance, and greater scalability.

The Adaptec 1220SA is a robust SATA RAID controller designed for small to medium-sized businesses. It supports RAID levels 0, 1, 1E, 5, and 10, providing flexibility for users to optimize data redundancy and performance. With the capability of handling up to four SATA drives, it guarantees an efficient and reliable setup while minimizing potential data loss. The controller also features an intuitive web-based management interface, making it easier to administer and configure.

The Adaptec 1430SA extends similar functionality with enhanced features. It is designed to accommodate up to eight SATA drives and supports the latest 3 Gbps SATA technology. This model includes optional battery backup for preserving critical data during unexpected power outages, ensuring that users maintain data integrity and protection at all times.

In the enterprise domain, the Adaptec 44300 shines as a high-performance RAID controller. It offers support for 12 SATA drives, which allows for expansive storage scalability, crucial for data-intensive applications. The advanced RAID features include support for RAID 6, providing dual parity data protection. The controller is built with a powerful processor and memory, allowing for faster data processing and enhanced throughput.

The Adaptec 1225SA is another noteworthy model. Designed for entry-level RAID applications, it offers a balanced combination of performance and reliability. Supporting up to four SATA drives, the 1225SA is particularly well-suited for environments where uptime is critical, delivering functionalities such as hot-swapping. This feature allows users to replace failed drives without shutting down the system, significantly reducing downtime.

Lastly, the Adaptec 1420SA caters to users who require a cost-effective but reliable storage solution. With support for RAID 0, 1, and JBOD, it is a versatile option for enthusiasts and small businesses. The controller can manage up to two SATA drives, making it ideal for basic applications where simplicity and efficiency are paramount.

Collectively, these Adaptec controllers showcase cutting-edge RAID technology and storage management features, reinforcing their position as reliable options for users ranging from home users to enterprise-level organizations seeking optimal data storage solutions.