build

Background initialization of a redundant array. The array is accessible throughout. RAID 1 copies the contents of the primary drive to a secondary drive. See clear.

bus

See channel.

C

cache

Fast-access memory on the controller that serves as intermediate storage for data that is read from, or written to, drives.

capacity

Total usable space available in megabytes or gigabytes.

channel

Any path, or bus, used for the transfer of data and the control of information between storage devices and a RAID controller. For SATA channels, each channel has a single drive capacity.

check point

A feature that enables you to exit the ACU when an operation is in progress and be able to continue without interruption. The driver then resumes the operation from where the BIOS left off and the BIOS resumes the operation where the driver left off.

chunk

See stripe.

clear

Foreground initialization of a fault-tolerant array. A clear operation zeros all blocks of the array. The array is not accessible until the clear task is complete.

concatenation

Joining of physical or logical drives in sequential order.

configure

Process of preparing a disk for use by the controller. When a disk is configured, the controller records the RAID signature on the disk.

configured array

An array that is ready for data reads and writes. Arrays can be configured by build or clear.

consistency check command

Command that reads all the blocks of a RAID 1 to determine if the blocks are consistent. Any inconsistent blocks are fixed.

D

dead partition

See failed.

degraded

A redundant (for example, a RAID 1) array in which one or more members have failed. The data is intact but redundancy has been compromised. Any further failure would cause the array to fail and result in data loss.

disk

Physical disk drive. Randomly accessible, rewriteable data storage device. Also called hard disk.

Image 95
Contents SAS and Sata HostRAID Controller Copyright Adaptec Customer Support Limited 3-Year Hardware Warranty Regulatory Compliance Statements Contents Getting Started Managing Your Storage Space Using the ARC Utility Safety Information What You Need to Know Before You Begin About This GuideConventions Used in This Guide How to Find More InformationWhat You Need to Know Before You Begin Terminology Used in this GuideAbout This Guide l About Your HostRAID Controller Array Level Features HostRAID Controller FeaturesAbout Your HostRAID Controller l PCI-X About the Adaptec 58300 ControllerAbout the Adaptec 48300 Controller About the Adaptec 44300 Controller About the Adaptec 1430SA Controller About the Adaptec 1420SA Controller About the Adaptec 1220SA Controller About the Adaptec 1225SA Controller Kit Contents and System Requirements System Requirements Kit ContentsInstalling the HostRAID Controller Disk Drives Before You Begin Installing the HostRAID ControllerSelecting SAS Cables Selecting Disk DrivesInstalling the HostRAID Controller and Disk Drives l Selecting Sata Cables Connecting Disk Drives to SAS HostRAID ControllersConnecting to a Backplane Connecting Directly to the HostRAID ControllerChecking Your Controller and Devices Connecting Disk Drives to Sata HostRAID ControllersInstalling the SAS HostRAID Controller to a SAS Expander Setting the Boot Controller Next Steps Getting Started Choosing a RAID Level Choosing Installation OptionsBasic Installation Steps Installing with an Operating SystemInstalling on an Existing Operating System Creating a Bootable Array Creating an Array with Adaptec Storage Manager Creating an ArrayCreating an Array with the ACU Select Express configuration..., then click Next Making Your Array BootableInstalling the Driver and an Operating System Creating a Driver Disk Installing with WindowsInstalling with Suse Linux Installing with Red Hat LinuxInstalling with NetWare Installing the Driver on an Existing Operating System Creating a Driver Disk or an Array Installing on Windows XP or WindowsInstalling on NetWare Installing on Windows VistaInstalling on Red Hat or Suse Linux Continue with Managing Your Storage Space on Managing Your Storage Space About Adaptec Storage Manager About the Hrconf Command Line UtilityInstalling Adaptec Storage Manager Which Utility Should I Use? About the ARC UtilityAbout the Adaptec Flash Utility Solving Problems Failed Disk Drive Not Protected by a Hot Spare Troubleshooting ChecklistRecovering from a Disk Drive Failure Failed Disk Drive Protected by a Hot SpareMultiple Failures in the Same Array Resetting the ControllerFailure in Multiple Arrays Simultaneously Disk Drive Failure in a RAID 0 ArraySolving Problems l Understanding RAID Stripe-Unit Size RAID Technology OverviewRAID 0 Non-RAID Arrays Understanding Drive SegmentsRAID 10 Arrays RAID 1 ArraysSelecting the Best RAID Level Introduction to SAS Terminology Used in This Appendix What is SAS?What’s a SAS Port? How Do SAS Devices Communicate?What’s a Phy? How are Disk Drives Identified in SAS? What’s a SAS Connector?What’s a SAS Address? What do SAS Cables Look Like?SAS Expander Connections What are the SAS Connection Options?Direct-Attach Connections Backplane ConnectionsSAS Domain How is SAS Different from Parallel SCSI?Parallel Scsi Serial Attached Scsi Using the ARC Utility Creating a New Array Introduction to the ARC UtilityRunning the ARC Utility Creating and Managing ArraysQuick Init Creating a RAID 0 on new drives Viewing Array Properties Managing ArraysRebuilding Arrays Enabling/Disabling Write Cache Adding/Deleting Hot SparesDeleting Arrays Atapi Support Using SerialSelectManaging Bootable Arrays and Devices Configuring Disk DrivesDevice SerialSelect OptionsPHY Configuration Using SATASelectSATASelect Options Formatting and Verifying Disk DrivesIdentifying Disk Drives Locating Disk DrivesViewing the Event Log DOS Using the Adaptec Flash Utility forObtaining the Firmware IntroductionCompatibility Information Running the Menu-Based AFU Running the AFUCreating the Firmware Kit On Floppy Disks Examples AFU CommandsRunning the AFU from the Command Line Example Command SyntaxCommand Switches Update \ AFU Verify /C Updating Flash Using AFU Command LineTo update a single HostRAID controller HostRAID Controller LED and I2C Connector Reference Adaptec 48300 Activity LED Connector Specification Adaptec 58300 Activity LED Connector SpecificationAdaptec 1430SA Activity LED and I2C Connector Specification Adaptec 44300 Activity LED Connector SpecificationLedsum Adaptec 1420SA Activity LED and I2C Connector SpecificationAdaptec 1225SA Activity LED Specification Adaptec 1220SA Activity LED Connector SpecificationElectrostatic DischargeESD Safety InformationTechnical Specifications Current Requirements Environmental SpecificationsDC Power Requirements Glossary Build ConfigureConfigured array Consistency check commandEvent Fault-tolerant arrayDisk ID Drive LEDLow-level format Native Command QueuingLegacy disk Logical deviceRebuild RAID volumeSimple volume RAID signatureTask VolumeStripe size Striped arrayACU IndexSATASelect SerialSelect utilities SATASelect Adaptec, Inc

1430SA, 1225SA, 1420SA, 1220SA, 48300 specifications

Adaptec, a prominent name in the world of storage solutions, offers a diverse array of RAID controller cards aimed at enhancing data storage and management in both consumer and enterprise markets. Among its acclaimed products are the Adaptec 1220SA, 1430SA, 44300, 1225SA, and 1420SA. These cards ensure increased data protection, improved performance, and greater scalability.

The Adaptec 1220SA is a robust SATA RAID controller designed for small to medium-sized businesses. It supports RAID levels 0, 1, 1E, 5, and 10, providing flexibility for users to optimize data redundancy and performance. With the capability of handling up to four SATA drives, it guarantees an efficient and reliable setup while minimizing potential data loss. The controller also features an intuitive web-based management interface, making it easier to administer and configure.

The Adaptec 1430SA extends similar functionality with enhanced features. It is designed to accommodate up to eight SATA drives and supports the latest 3 Gbps SATA technology. This model includes optional battery backup for preserving critical data during unexpected power outages, ensuring that users maintain data integrity and protection at all times.

In the enterprise domain, the Adaptec 44300 shines as a high-performance RAID controller. It offers support for 12 SATA drives, which allows for expansive storage scalability, crucial for data-intensive applications. The advanced RAID features include support for RAID 6, providing dual parity data protection. The controller is built with a powerful processor and memory, allowing for faster data processing and enhanced throughput.

The Adaptec 1225SA is another noteworthy model. Designed for entry-level RAID applications, it offers a balanced combination of performance and reliability. Supporting up to four SATA drives, the 1225SA is particularly well-suited for environments where uptime is critical, delivering functionalities such as hot-swapping. This feature allows users to replace failed drives without shutting down the system, significantly reducing downtime.

Lastly, the Adaptec 1420SA caters to users who require a cost-effective but reliable storage solution. With support for RAID 0, 1, and JBOD, it is a versatile option for enthusiasts and small businesses. The controller can manage up to two SATA drives, making it ideal for basic applications where simplicity and efficiency are paramount.

Collectively, these Adaptec controllers showcase cutting-edge RAID technology and storage management features, reinforcing their position as reliable options for users ranging from home users to enterprise-level organizations seeking optimal data storage solutions.