Install SFPs or XFPs on the SCM
Filler plug installation
If XFP or SFP transceivers are removed, install either replacement transceivers or filler plugs in the sockets to protect the internal components of the SCM.
Additional filler plugs can be ordered from the applicable manufacturer; for a list of tested and qualified transceivers and filler plugs, see the Support section of the RadiSys Web site at www.radisys.com.
Install fillers plugs using the insertion guidelines described below:
XFP filler plug installation
If the SCM is oriented vertically, insert the filler plug so the recessed side is on the left and the flat, smooth side is on the right.
If the SCM is oriented horizontally, insert the filler plug so the recessed side is on the bottom and the flat, smooth side is on the top.
XFP vertical insertion | XFP horizontal insertion |
|
|
| Connector side |
|
| Plug handle |
|
|
|
| |||
Connector side | Recessed side | Plug handle | is on bottom Recessed side | |||
is on left |
| is on bottom |
| |||
| is on left |
|
|
|
|
|
SFP filler plug installation
If the SCM is oriented vertically, insert the filler plug so the connector side and retaining clip are on the left.
If the SCM is oriented horizontally, insert the filler plug so the connector side and retaining clip are on the bottom.
SFP vertical insertion | SFP horizontal insertion |
Connector | Connector side |
side is on left | is on bottom |
| Retaining clip |
Retaining clip | is on bottom |
is on left |
|