Verify switch operation

Verify switch operation

Use these steps to view port status and to enable ports on the Base Ethernet and the Fabric Ethernet switches.

View port status

1.Verify you are at this prompt.

ATCA-2210#

If you are not at the appropriate prompt, see Connect to the SCM on page 6 for instructions on how to get there.

2.Enter the applicable command for the switch you are verifying.

Switch

Command to enter

Resulting prompt

Base Ethernet

base-ethernet

ATCA-2210-Base#

Fabric Ethernet

fabric-ethernet

ATCA-2210-Fabric#

3.Enter this command to show the status of the ports. show port all

View the status information of the ports to see which ports are enabled. If needed, press the space bar to view more of the list.

4.Proceed to the applicable section or step:

ƒTo enable all ports, see Enable all ports on page 8.

ƒTo enable only specific ports, see Enable specific ports on page 8.

ƒTo leave all ports disabled, continue with step 5.

5.Enter the exit command to return to the ATCA-2210#prompt.

If you are asked to save changes, enter y for yes or n for no. If you choose y for yes, this configuration is saved as the startup configuration.

6.Enter the exit command to log off the SCM.

7.If you have two SCMs installed, repeat the above steps on the other SCM.

7

Image 7
Contents Prepare for installation Obey ESD precautionsInstall SFPs or XFPs on the SCM Transceiver installation Configuration recommendationsXFP filler plug installation Filler plug installationRadiSys shelf SCM installation checklistShelf After installation of the SCM SCM’s on-board Shelf ManagerATCA-6006, 5U, 6-slot Install the SCM in the shelfPush inner latch in all the way Pull out Showing ATCA-2210# Connect to the Ethernet maintenance portConnect to the SCM Connect to the serial portFabric-ethernet Verify switch operationView port status Base-ethernetEnable specific ports Enable all portsATCA-2210-Base# ATCA-2210-Fabric# ATCA-2210# prompt Where s and p have the following valuesBase Ethernet switch internal ports Interface s/pRoot@ATCA-2210@ Debugmode ~# Disable the Shelf Manager on the SCMVerify shelf management operation ATCA-2210#Rsysdebug Rsysdebug -hRsysdebug -i Resysdebug -h Enable the Shelf Manager on the SCMSER on the SCM As a laptopRear I/O connectivity COM Express module setupWhere to go from here SCM ShMgr Mode EnabledWhere to get more product information