Symantec manual Interface s/p, Where s and p have the following values, ATCA-2210# prompt

Page 9

Verify switch operation

B.Enter the specific port (interface) number to enable. The s variable represents the specified slot. The p variable represents an individual port within the group of ports for the specified slot.

interface <s/p>

Where s and p have the following values:

Base Ethernet switch interfaces

 

 

ATCA-6000 backplane slots

s=0

p=1-6, 9-14

ATCA-6006 backplane slots

s=0

p=3-6

ATCA-6014 backplane slots

s=0

p=1-6, 9-14

ATCA-6016 backplane slots

s=0

p=1-7, 10-16

Front panel optical

s=1

p=5-9

Internal ports

s=2

p=1, 3-4

RTM

s=3

p=5-8 or p=5-6 (depends on SCM configuration)

Base Ethernet switch internal ports

2/1 – The link between SCMs when two SCMs are installed. The port is enabled by factory default. 2/3 – The Base Ethernet link to the COM Express site.

2/4 – The link to standalone Shelf Manager sites on non-RadiSys shelves.

Fabric Ethernet switch interfaces

 

 

ATCA-6000 backplane slots

s=0

p=1-6, 9-14

ATCA-6006 backplane slots

s=0

p=3-6

ATCA-6014 backplane slots

s=0

p=1-6, 9-14

ATCA-6016 backplane slots

s=0

p=1-7, 10-16

Front panel optical

s=1

p=1-4

Internal ports

s=2

p=3

RTM

s=3

p=1 or p=1-3 (depends on SCM configuration)

Fabric Ethernet switch internal port

2/3 – The Fabric Ethernet link to the COM Express site.

Note: See the ATCA-5010 Shelf Peripheral Module Reference for details on which RTM ports are available for each SCM board configuration.

C.Enable the port. Enter no shutdown.

If you are disabling the interface, enter shutdown.

D.To enable another port, enter the exit command and perform the procedures described in Steps B and C.

If finished enabling ports, enter the exit command at each prompt until you reach the

ATCA-2210# prompt.

Note: If you are asked to save changes, enter y for yes or n for no. If you choose y for yes, this configuration is saved as the startup configuration.

9

Image 9
Contents Obey ESD precautions Prepare for installationInstall SFPs or XFPs on the SCM Transceiver installation Configuration recommendationsXFP filler plug installation Filler plug installationShelf After installation of the SCM SCM installation checklistSCM’s on-board Shelf Manager RadiSys shelfInstall the SCM in the shelf ATCA-6006, 5U, 6-slotPush inner latch in all the way Pull out Connect to the SCM Connect to the Ethernet maintenance portConnect to the serial port Showing ATCA-2210#View port status Verify switch operationBase-ethernet Fabric-ethernetEnable all ports Enable specific portsATCA-2210-Base# ATCA-2210-Fabric# Base Ethernet switch internal ports Where s and p have the following valuesInterface s/p ATCA-2210# promptVerify shelf management operation Disable the Shelf Manager on the SCMATCA-2210# Root@ATCA-2210@ Debugmode ~#Rsysdebug -h RsysdebugRsysdebug -i SER on the SCM Enable the Shelf Manager on the SCMAs a laptop Resysdebug -hWhere to go from here COM Express module setupSCM ShMgr Mode Enabled Rear I/O connectivityWhere to get more product information