Installation Guide

Configuration recommendations

Standard SCM configurations come without SFP or XFP transceivers installed. To protect the internal components of the SCM, transceivers or filler plugs must be installed in all empty sockets:

ƒThe Base Ethernet configuration supports up to four SFP transceivers and one XFP transceiver, with filler plugs installed in unused sockets.

ƒThe Fabric Ethernet configuration supports up to four XFP transceivers, with filler plugs installed in unused sockets.

For a list of tested and qualified transceivers and filler plugs, see the Support section of the RadiSys Web site at www.radisys.com.

Transceiver installation

SFP and XFP transceivers can be installed on the SCM at any time, but RadiSys recommends performing the installation before the SCM is installed in the shelf.

The illustration shows the correct orientation for inserting an SFP transceiver. The SFP you use may vary in appearance depending on manufacturer, but should follow the same insertion guidelines. Use these same guidelines when inserting XFP transceivers as well.

1.Follow ESD precautions and make sure you are adequately grounded.

2.Remove the transceivers and the SCM from their antistatic bags.

3.On the SCM’s faceplate, remove the filler plugs from the sockets in which you are installing the SFP or the XFP transceivers. For sockets not being used, keep the filler plugs in place to protect the internal components of the board.

4.Make sure the transceiver’s bale (the latch on the cable side of the transceiver) is in the closed position. This ensures that the transceiver will snap into position when inserted into the socket.

Cable side

Cable side

Vertical insertion

Connector side is on left

Horizontal insertion

Connector side is down

Bale in

closed position

5.How you insert the transceiver into the socket depends on the SCM’s orientation:

ƒIf the SCM is oriented vertically, insert the transceiver so the connector side is on the left.

ƒIf the SCM is oriented horizontally, insert the transceiver so the connector side is down.

6.Once inserted into the socket, carefully slide the transceiver until its connector is fully seated and snaps into position.

7.Repeat the above steps for each transceiver being installed.

8.For transceivers with cable plugs installed on their cable side, keep the plugs in place until you are ready to plug cables into the transceivers. The cable plugs protect the internal components of the transceivers.

2

Image 2
Contents Install SFPs or XFPs on the SCM Obey ESD precautionsPrepare for installation Configuration recommendations Transceiver installationFiller plug installation XFP filler plug installationSCM’s on-board Shelf Manager SCM installation checklistShelf After installation of the SCM RadiSys shelfPush inner latch in all the way Pull out Install the SCM in the shelfATCA-6006, 5U, 6-slot Connect to the serial port Connect to the Ethernet maintenance portConnect to the SCM Showing ATCA-2210#Base-ethernet Verify switch operationView port status Fabric-ethernetATCA-2210-Base# ATCA-2210-Fabric# Enable all portsEnable specific ports Interface s/p Where s and p have the following valuesBase Ethernet switch internal ports ATCA-2210# promptATCA-2210# Disable the Shelf Manager on the SCMVerify shelf management operation Root@ATCA-2210@ Debugmode ~#Rsysdebug -i Rsysdebug -hRsysdebug As a laptop Enable the Shelf Manager on the SCMSER on the SCM Resysdebug -hSCM ShMgr Mode Enabled COM Express module setupWhere to go from here Rear I/O connectivityWhere to get more product information