Symantec ATCA-2210 manual Verify shelf management operation, Disable the Shelf Manager on the SCM

Page 10

Installation Guide

3.Enter the exit command again, to log off the SCM.

4.If you have two SCMs installed, repeat these steps on the other SCM.

Verify shelf management operation

These steps confirm that shelf management is operating when the SCM is installed in a RadiSys shelf. If the SCM is installed in a non-RadiSys shelf, shelf management is not available.

1.Verify that you are at this prompt.

ATCA-2210#

If you are not at the appropriate prompt, see Connect to the SCM on page 6 for instructions on how to get there.

2.Enter this command to get to the platform management command line interface (CLI). platform-mgmt

3.Enter this command and verify that the Shelf Manager is started. shelf-mgmt show all

If unknown appears instead of Active or Standby for the Status, the Shelf Manager is not operational. Refer to the troubleshooting section of the Shelf Management Software Reference for a list of possible solutions.

4.Enter this command to exit the platform management CLI. exit

5.If you have two SCMs installed, repeat these steps on the other SCM.

Disable the Shelf Manager on the SCM

By default, the SCM is configured to function in a RadiSys shelf. For an SCM to operate in a non-RadiSys shelf, you must disable the Shelf Manager on the SCM.

1.Connect the included serial port cable by plugging one end into the RJ-45 serial port labeled “LMP SER” on the SCM.

2.Connect the cable’s other end to the COM1 or the COM2 serial port of an external computer, such as a laptop.

3.Start a terminal-emulator application, such as Procomm Plus® or minicom, from the operating system on your computer or laptop. Specify 115,200 baud, 8 data bits, no parity, one stop bit, and no hardware or software flow control.

4.Press the Enter key and verify you get a login prompt. Enter root at the prompt.

5.The following displays at the prompt of the connected computer:

root@ATCA-2210@ DEBUGMODE :~#

This DEBUGMODE prompt is a result of a conflict between the Shelf Manager on the SCM and the Shelf Manager on the non-RadiSys shelf. Disabling the Shelf Manager on the SCM resolves this conflict.

10

Image 10
Contents Prepare for installation Obey ESD precautionsInstall SFPs or XFPs on the SCM Configuration recommendations Transceiver installationFiller plug installation XFP filler plug installationSCM’s on-board Shelf Manager SCM installation checklistShelf After installation of the SCM RadiSys shelfATCA-6006, 5U, 6-slot Install the SCM in the shelfPush inner latch in all the way Pull out Connect to the serial port Connect to the Ethernet maintenance portConnect to the SCM Showing ATCA-2210#Base-ethernet Verify switch operationView port status Fabric-ethernetEnable specific ports Enable all portsATCA-2210-Base# ATCA-2210-Fabric# Interface s/p Where s and p have the following valuesBase Ethernet switch internal ports ATCA-2210# promptATCA-2210# Disable the Shelf Manager on the SCMVerify shelf management operation Root@ATCA-2210@ Debugmode ~#Rsysdebug Rsysdebug -hRsysdebug -i As a laptop Enable the Shelf Manager on the SCMSER on the SCM Resysdebug -hSCM ShMgr Mode Enabled COM Express module setupWhere to go from here Rear I/O connectivityWhere to get more product information