SUPER MICRO Computer X9DRD-iF, X9DRD-LF user manual Onboard Power LED, BMC Heartbeat LED States

Page 67

Chapter 2: Installation

Onboard Power LED

An Onboard Power LED is located at LED2 on the motherboard. When this LED is on, the system is on. Be sure to turn off the system and unplug the power cord before removing or installing compo- nents. See the table on the right for more information.

Onboard PWR LED Indicator

LED States

LED Color

 

Definition

Off

 

System Off (PWR cable

 

 

 

not connected)

Green

 

System On

 

Green:

 

ACPI S1 State

 

Flashing

 

 

Quickly

 

 

 

 

 

BMC Heartbeat LED

A BMC Heartbeat LED is located at LEDM1 on the motherboard. When LEDDM1 is blinking, BMC functions normally. See the table on the right for more information.

BMC Heartbeat LED

States

Color/State Definition

Green:

BMC: Normal

Blinking

 

 

 

COM2

 

BMC CTRL

CPU1 SLOT3

CPU1 SLOT4

 

B1

 

LEDM

 

BMC

 

LAN CTRL

 

6

CPU1 SLOT5

CPU2 SLOT6

LED3JUIDB

CPU2

SLOT7

 

 

 

USB2/3

USB0/1

 

 

 

JIPMB1

VGA

 

 

 

COM1

 

USB6

 

 

 

 

 

 

 

FAN8

FAN7

LAN2

LAN1

IPMI_LAN

 

 

 

JPG1

 

 

 

 

 

 

 

LAN

 

 

 

1

 

JPB1

 

 

 

SP1

 

 

 

CTRL

 

 

 

 

 

 

JPL1

1

JD 2

1

 

 

 

JI2C1

 

 

CLK CTRL

JVRM I2C

JVRM I2C

 

JTPM

JI2C2

 

 

 

 

 

 

 

A. PWR LED B. BMC LED

PCI-E

PCI-E

3.0

3.0

X8

X8

PCI-E

PCI

3.0 X8

-E 3.0 X1

PCI-E 3.0 X8

X9DRD-iF

Rev. 1.10

JPW4

 

 

 

 

 

PCH

 

G1

H1

 

 

 

 

F1

E1

2

 

 

 

 

 

 

 

 

CPU2

 

 

 

 

 

JPME

 

 

 

 

 

JBT1

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

JPME

 

 

 

 

 

JRK1

 

 

 

 

 

 

 

 

JWD1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A0ATI-S

 

 

JSD1 A1ATI

 

BIOS

 

 

 

 

 

 

 

 

 

 

 

-S

 

 

 

 

 

 

 

 

 

 

 

A2ATI-

 

 

A3ATI-S

C1

D1

B1

A1

 

 

 

 

 

 

 

S

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I-SATA4

 

 

I-SATA5

 

 

CPU1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SCU0

 

 

SCU1

 

 

 

 

 

 

 

 

 

 

 

SCU2

 

 

SCU3

 

 

 

 

 

 

JVR2

 

 

 

 

 

USB4/5

 

 

 

 

 

 

 

 

 

 

 

 

 

T-SGPIO1

USB8/9

T-SGPIO2

 

 

 

 

 

 

JBAT1

 

JPW3

JPW1

 

 

 

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+JOH1

 

 

 

JSTBY1

1JL

 

S-SGPIO1

 

 

 

 

 

 

FP

 

JPW2

 

 

 

 

 

 

 

 

 

 

 

 

LED2

 

 

 

 

FAN6

 

 

 

FAN5

 

JPW5

FAN3

FAN2

FAN1

CTRL

1JF

JPI2C1

 

 

 

 

 

FAN4

 

 

 

 

 

 

 

 

 

JVR1

 

 

 

 

 

 

 

 

2-41

Image 67
Contents X9DRD-iF X9DRD-LF Page Manual Organization About This MotherboardConventions Used in the Manual Europe Contacting SupermicroAsia-Pacific Table of Contents Vii Appendix a Bios Error Beep Codes Overview ChecklistX9DRD-iF Motherboard Image X9DRD-iF Motherboard Layout X9DRD-iFX9DRD-iF Quick Reference X9DRD-iFX9DRD-iF/LF Jumpers ConnectorsJuidb LAN1/LAN2 Ipmi LAN SP1 LED IndicatorsCPU Motherboard FeaturesSuper I/O SerialLink ConnectionsIntegrated Ipmi Serial COM PortFan Control CPU MonitoringSystem Block Diagram X9DRD-iF Block DiagramPCH C602 PCH C606 X9DRD-LF Block DiagramProcessor and Chipset Overview PC Health Monitoring Special FeaturesRecovery from AC Power Loss Environmental Temperature ControlPower Supply Acpi FeaturesSlow Blinking LED for Suspend-State Indicator Super I/O Advanced Power ManagementManagement Engine ME Overview of the Nuvoton WPCM450 Controller Other Features Supported by the Wpcm BMC ControllerPage X9DRD-iF/LF Motherboard User’s Manual Standardized Warning Statements Battery HandlingPage 製品の廃棄 Product DisposalPage Installing the LGA2011 Processor Processor and Heatsink InstallationLever Close 1st Socket Press down on LoadSocket Keys CPU Keys Labelled Open Gently close Push down and lock Load platePush down Lock the leverMounting Holes Installing a Passive CPU HeatsinkScrew#1 MotherboardRemoving the Heatsink Release Tabs Installing and Removing the Memory ModulesInstalling & Removing DIMMs Removing Memory ModulesProcessor and Memory Module Population Processors and their Corresponding Memory ModulesSee the Note Below Populating Udimm ECC/Non-ECC Memory ModulesData See the Note Below Intel E5-2600 Series Processor Udimm Memory SupportQRx8 Per Dimm Slots Per Channel Data See the NoteBelow 35V QRx4 8Rx4An Important Note on PCI-E Slot Population Motherboard InstallationTools Needed Location Mounting HolesInstalling the Motherboard Back Panel Connectors and I/O Ports Control Panel Connectors and I/O PortsBack Panel I/O Port Locations and Definitions Video Connection Serial PortsSerial COM Ports Pin Definitions FP USB 4/5, 8/9, USB Pin Definitions Universal Serial Bus USBBackplane USB 0/1, 2/3 Pin Definitions Pin# Definition +5V PO+ GroundTD0+ Act LED Ethernet PortsLAN Ports Pin Definition Pin# DefinitionStatus Unit Identifier Switch/UID LED IndicatorsUID Switch Pin# Definition Ground ButtonGround JF1 Header PinsFront Control Panel NIC1 Link LEDNMI Button Power LEDPower LED Pin Definitions JF1 Front Control Panel Pin DefinitionsPin# Definition 13 3.3V Standby HD Active NIC1/NIC2 LED IndicatorsPin# Definition Vcc NIC 2 LED 11 Vcc NIC 1 LED OH/Fan Fail/PWR Fail LED Status Red LED Power Fail LEDOverheat OH/Fan Fail/PWR Fail OH/Fan Fail/ PWR Fail/BlueUID LED Pin Definitions JF1Power Button Pin Definitions JF1 Reset ButtonPower Button Reset Button Pin Definitions JF112V 8-pin PWR Con Nector Pin Definitions Connecting CablesPower Connectors ATX Power 24-pin Connector Pin DefinitionsChassis Intrusion Pin Definitions Fan HeadersChassis Intrusion Fan Header Pin DefinitionsInternal Speaker Power LED/SpeakerPWR LED Connector Pin Definitions Speaker Connector Pin SettingsOverheat LED Pin Definitions TPM Header/PortOverheat LED/Fan Fail TPM/Port 80 Header Pin DefinitionsPin# Definition Data Ground Clock No Connection Power SMB I2C ConnectorPin# Definition Clock Data PWR Fail Ground +3.3V Ipmb Header Pin DefinitionsPin# Definition +5V Ground DOM Power Connector X9DRD-iFSgpio 1/2 & 3-SGPIO 1 Headers X9DRD-iF Pin# Definition Ground Data Load ClockStandby PWR Pin Definitions Standby Power Header X9DRD-iFPin# Definition +5V Standby Ground Wake-up Jumper Setting Definition Enabled default Disabled Jumper SettingsGlan Enable/Disable Glan Enable Jumper SettingsOpen Disabled Watch Dog Enable/DisableWatch Dog Jumper Settings Jumper Setting Definition Pins Reset defaultBMC Enable Jumper Settings VGA EnableBMC Enable VGA Enable Jumper Settings ME Mode Select Management Engine ME Recovery Manufacture Mode Select X9DRD-iF ME RecoveryI2C Bus to PCI-Exp. Slots I2C to PCI-E slots Jumper SettingsLink LED Activity LED Onboard LED IndicatorsGlan LEDs Ipmi Dedicated LAN LEDsBMC Heartbeat LED Onboard Power LEDBMC Heartbeat LED States Pin# Definition Ground TXP TXN RXN RXP Sata Ports/SCU ConnectorsSATA/SCU Connections Serial ATA/SCU Pin DefinitionsBefore Power On Troubleshooting ProceduresNo Power Losing the System’s Setup Configuration System Boot FailureNo Video When the System Becomes Unstable Memory ErrorsSystem becomes unstable before or during OS installation Technical Support Procedures Battery Removal Battery Removal and InstallationProper Battery Disposal Battery Installation Frequently Asked Questions Returning Merchandise for Service How To Change the Configuration Data Starting Bios Setup UtilityIntroduction Starting the Setup Utility Main SetupBuild Date System DateSystem Time Supermicro X9DRD-iF series VersionBoot Features Advanced Setup ConfigurationsCPU Configuration Power ConfigurationSocket 1 CPU Information/Socket 2 CPU Information Hyper-threading CPU Speed64-bit Clock Spread SpectrumIntel AES-NI Hardware Prefetcher Available when supported by the CPUDCU Streamer Prefetcher Available when supported by the CPU Limit Cpuid MaximumTurbo Mode Available when Power Technology is set to Custom  CPU Power Management ConfigurationPower Technology Eist Available when Power Technology is set to CustomEnergy Performance Factory Long Duration Power LimitLong Duration Power Limit Recommended Short Duration PowerIntegrated IO Configuration Chipset Configuration North BridgeQPI Configuration Sparing Memory ModeDram Rapl Mode MirroringSouth Bridge Configuration SATA Configuration SCU Storage Control Unit Configuration PCIe/PCI/PnP Configuration Serial Port 1 Configuration Super IO ConfigurationSerial Port Console Redirection Serial Port 2 ConfigurationConsole Redirection Settings ACPI Setting TPM Enable Status Intel ME Subsystem Configuration Intel TXT LT-SX ConfigurationLink Speed NIC ConfigurationBlink LEDs Event Logs Change Smbios Event Log SettingsView Smbios Event Log Erasing Settings Erase Event LogWhen Log is Full Smbios Event Log Standard Settings Log System Boot EventSystem Event Log Erasing Settings Erase SELWhen SEL is Full IpmiBMC Network Configuration CSM Support BootDelete Boot Options Boot Option #1/ Boot Option #2/ Boot Option #3User Password Administrator PasswordSecurity Save Options Save Changes Save Changes and ResetSave & Exit Discard Changes and ExitBoot Override Restore Optimized DefaultsSave as User Defaults Restore User DefaultsX9DRD-iF/LF Motherboard User’s Manual X9 Motherboard Bios Error Beep Codes Bios Error Beep CodesX9DRD-iF/LF Motherboard User’s Manual Driver/Tool Installation Display Screen Installing Software ProgramsSuperDoctor III Interface Display Screen Health Information Configuring SuperDoctorSuperDoctor III Interface Display Screen Remote Control X9DRD-iF/LF Motherboard User’s Manual