SUPER MICRO Computer X9DRD-iF, X9DRD-LF Power Button, Reset Button Pin Definitions JF1

Page 53

Chapter 2: Installation

Reset Button

The Reset Button connection is located on pins 3 and 4 of JF1. Attach it to a hardware reset switch on the computer case. Refer to the table on the right for pin definitions.

Power Button

The Power Button connection is located on pins 1 and 2 of JF1. Momentarily contacting both pins will power on/off the system. This button can also be con- figured to function as a suspend button (with a setting in the BIOS - See Chapter 4). To turn off the power when the system is in suspend mode, press the button for 4 seconds or longer. Refer to the table on the right for pin definitions.

Reset Button

Pin Definitions (JF1)

Pin# Definition

3Reset

4Ground

Power Button

Pin Definitions (JF1)

Pin# Definition

1Signal

2Ground

COM2

LEDM

 

 

BMC CTRL

CPU1 SLOT3 PCI-E

CPU1 SLOT4 PCI-E

CPU1 SLOT5 PCI-E

3.0

3.0

3.0

X8

X8

X8

BMC

LAN CTRL

6 CPU2 SLOT6 PCI-E 3.0 X1

LED3

JIPMB1

 

 

USB2/3

USB0/1

 

 

 

JUIDB

 

VGA

 

 

 

COM1

 

USB6

 

 

 

 

 

 

 

FAN8

FAN7

LAN2

LAN1

IPMI_LAN

 

 

 

 

JPG1

 

LAN

 

 

 

1

 

 

JPB1

 

 

 

SP1

 

 

 

 

 

CTRL

JPL1

1

JD 2

1

 

 

 

 

CPU2

JI2C2

 

 

CLK CTRL

JVRM I2C

JVRM I2C

 

JTPM

 

JI2C1

 

 

 

 

 

 

SLOT7

 

JPW4

PCI-E 3.0

X9DRD-iF

 

X8

Rev. 1.10

 

A. Reset Button B. PWR Button

 

 

 

PCH

2

 

 

 

JPME

 

 

 

1

 

 

 

JPME

 

 

 

JWD1

 

 

 

A0ATI-S

JSD1 A1ATI

 

 

-S

 

 

A2ATI-

A3ATI-S

C1

D1

 

 

S

 

 

 

I-SATA4

I-SATA5

 

 

SCU0

SCU1

 

 

SCU2

SCU3

 

 

 

USB4/5

 

 

BIOS

CPU1

G1 H1

JBT1

JRK1

B1 A1

F1

E1

CPU2

 

JVR2

Ground

X

FP PWRLED

HDD LED

NIC1 Link LED

NIC2 Link LED

Blue+ (OH/Fan Fail/

PWR FaiL/UID LED)

20

19

NMI

X

3.3 V

ID_UID_SW/3/3V Stby

NIC1 Activity LED

NIC2 Activity LED

Red+ (Blue LED Cathode)

 

USB8/9

 

 

T-SGPIO1

 

T-SGPIO2

 

JSTBY1

1 JL

S-SGPIO1

 

FAN6

 

FAN5

FAN4

 

 

 

 

 

JBAT1

 

JPW3

 

 

 

 

JPW1

 

 

 

 

+JOH1

 

 

 

 

 

 

JPW2

 

 

 

 

LED2

 

 

 

JPW5

 

 

FP

 

 

JVR1

FAN3

FAN2

FAN1

CTRL

1 JF

JPI2C1

 

 

 

 

 

 

Power Fail LED

Ground

Ground

2 1

3.3V A

Reset Reset Button

PWR Power Button

B

2-27

Image 53
Contents X9DRD-iF X9DRD-LF Page Manual Organization About This MotherboardConventions Used in the Manual Asia-Pacific Contacting SupermicroEurope Table of Contents Vii Appendix a Bios Error Beep Codes Overview ChecklistX9DRD-iF Motherboard Image X9DRD-iF Motherboard Layout X9DRD-iFX9DRD-iF Quick Reference X9DRD-iFX9DRD-iF/LF Jumpers ConnectorsJuidb LAN1/LAN2 Ipmi LAN SP1 LED IndicatorsCPU Motherboard FeaturesIntegrated Ipmi SerialLink ConnectionsSerial COM Port Super I/OFan Control CPU MonitoringSystem Block Diagram X9DRD-iF Block DiagramPCH C602 PCH C606 X9DRD-LF Block DiagramProcessor and Chipset Overview Recovery from AC Power Loss Special FeaturesEnvironmental Temperature Control PC Health MonitoringSlow Blinking LED for Suspend-State Indicator Acpi FeaturesPower Supply Management Engine ME Advanced Power ManagementSuper I/O Overview of the Nuvoton WPCM450 Controller Other Features Supported by the Wpcm BMC ControllerPage X9DRD-iF/LF Motherboard User’s Manual Standardized Warning Statements Battery HandlingPage 製品の廃棄 Product DisposalPage Installing the LGA2011 Processor Processor and Heatsink InstallationLever Close 1st Socket Press down on LoadSocket Keys CPU Keys Push down Gently close Push down and lock Load plateLock the lever Labelled OpenScrew#1 Installing a Passive CPU HeatsinkMotherboard Mounting HolesRemoving the Heatsink Installing & Removing DIMMs Installing and Removing the Memory ModulesRemoving Memory Modules Release TabsProcessor and Memory Module Population Processors and their Corresponding Memory ModulesSee the Note Below Populating Udimm ECC/Non-ECC Memory ModulesData See the Note Below Intel E5-2600 Series Processor Udimm Memory SupportBelow 35V QRx4 Per Dimm Slots Per Channel Data See the Note8Rx4 QRx8Tools Needed Motherboard InstallationLocation Mounting Holes An Important Note on PCI-E Slot PopulationInstalling the Motherboard Back Panel I/O Port Locations and Definitions Control Panel Connectors and I/O PortsBack Panel Connectors and I/O Ports Serial COM Ports Pin Definitions Serial PortsVideo Connection Backplane USB 0/1, 2/3 Pin Definitions Universal Serial Bus USBPin# Definition +5V PO+ Ground FP USB 4/5, 8/9, USB Pin DefinitionsLAN Ports Pin Definition Ethernet PortsPin# Definition TD0+ Act LEDUID Switch Unit Identifier Switch/UID LED IndicatorsPin# Definition Ground Button StatusFront Control Panel JF1 Header PinsNIC1 Link LED GroundPower LED Pin Definitions JF1 Power LEDFront Control Panel Pin Definitions NMI ButtonPin# Definition Vcc NIC 2 LED 11 Vcc NIC 1 LED NIC1/NIC2 LED IndicatorsPin# Definition 13 3.3V Standby HD Active Overheat OH/Fan Fail/PWR Fail Power Fail LEDOH/Fan Fail/ PWR Fail/BlueUID LED Pin Definitions JF1 OH/Fan Fail/PWR Fail LED Status Red LEDPower Button Reset ButtonReset Button Pin Definitions JF1 Power Button Pin Definitions JF1Power Connectors Connecting CablesATX Power 24-pin Connector Pin Definitions 12V 8-pin PWR Con Nector Pin DefinitionsChassis Intrusion Fan HeadersFan Header Pin Definitions Chassis Intrusion Pin DefinitionsPWR LED Connector Pin Definitions Power LED/SpeakerSpeaker Connector Pin Settings Internal SpeakerOverheat LED/Fan Fail TPM Header/PortTPM/Port 80 Header Pin Definitions Overheat LED Pin DefinitionsPin# Definition Clock Data PWR Fail Ground +3.3V Power SMB I2C ConnectorIpmb Header Pin Definitions Pin# Definition Data Ground Clock No ConnectionSgpio 1/2 & 3-SGPIO 1 Headers X9DRD-iF DOM Power Connector X9DRD-iFPin# Definition Ground Data Load Clock Pin# Definition +5V GroundPin# Definition +5V Standby Ground Wake-up Standby Power Header X9DRD-iFStandby PWR Pin Definitions Glan Enable/Disable Jumper SettingsGlan Enable Jumper Settings Jumper Setting Definition Enabled default DisabledWatch Dog Jumper Settings Watch Dog Enable/DisableJumper Setting Definition Pins Reset default Open DisabledBMC Enable VGA EnableVGA Enable Jumper Settings BMC Enable Jumper SettingsManufacture Mode Select X9DRD-iF Management Engine ME RecoveryME Recovery ME Mode SelectI2C Bus to PCI-Exp. Slots I2C to PCI-E slots Jumper SettingsGlan LEDs Onboard LED IndicatorsIpmi Dedicated LAN LEDs Link LED Activity LEDBMC Heartbeat LED States Onboard Power LEDBMC Heartbeat LED SATA/SCU Connections Sata Ports/SCU ConnectorsSerial ATA/SCU Pin Definitions Pin# Definition Ground TXP TXN RXN RXPNo Power Troubleshooting ProceduresBefore Power On No Video System Boot FailureLosing the System’s Setup Configuration When the System Becomes Unstable Memory ErrorsSystem becomes unstable before or during OS installation Technical Support Procedures Proper Battery Disposal Battery Installation Battery Removal and InstallationBattery Removal Frequently Asked Questions Returning Merchandise for Service Introduction Starting Bios Setup UtilityHow To Change the Configuration Data Starting the Setup Utility Main SetupSystem Time System DateSupermicro X9DRD-iF series Version Build DateBoot Features Advanced Setup ConfigurationsSocket 1 CPU Information/Socket 2 CPU Information Power ConfigurationCPU Configuration 64-bit CPU SpeedClock Spread Spectrum Hyper-threadingDCU Streamer Prefetcher Available when supported by the CPU Hardware Prefetcher Available when supported by the CPULimit Cpuid Maximum Intel AES-NIPower Technology  CPU Power Management ConfigurationEist Available when Power Technology is set to Custom Turbo Mode Available when Power Technology is set to CustomLong Duration Power Limit Factory Long Duration Power LimitRecommended Short Duration Power Energy PerformanceIntegrated IO Configuration Chipset Configuration North BridgeQPI Configuration Dram Rapl Mode Memory ModeMirroring SparingSouth Bridge Configuration SATA Configuration SCU Storage Control Unit Configuration PCIe/PCI/PnP Configuration Serial Port 1 Configuration Super IO ConfigurationSerial Port Console Redirection Serial Port 2 ConfigurationConsole Redirection Settings ACPI Setting TPM Enable Status Intel ME Subsystem Configuration Intel TXT LT-SX ConfigurationBlink LEDs NIC ConfigurationLink Speed Event Logs Change Smbios Event Log SettingsWhen Log is Full Erasing Settings Erase Event LogSmbios Event Log Standard Settings Log System Boot Event View Smbios Event LogWhen SEL is Full Erasing Settings Erase SELIpmi System Event LogBMC Network Configuration Delete Boot Options BootBoot Option #1/ Boot Option #2/ Boot Option #3 CSM SupportSecurity Administrator PasswordUser Password Save & Exit Save Changes and ResetDiscard Changes and Exit Save Options Save ChangesSave as User Defaults Restore Optimized DefaultsRestore User Defaults Boot OverrideX9DRD-iF/LF Motherboard User’s Manual X9 Motherboard Bios Error Beep Codes Bios Error Beep CodesX9DRD-iF/LF Motherboard User’s Manual Driver/Tool Installation Display Screen Installing Software ProgramsSuperDoctor III Interface Display Screen Health Information Configuring SuperDoctorSuperDoctor III Interface Display Screen Remote Control X9DRD-iF/LF Motherboard User’s Manual