PCIe/PCI/PnP Configuration

PCI ROM Priority

Use this feature to select the Option ROM to boot the system when there are mul- tiple Option ROMs available in the system. The options are EFI Compatible ROM and Legacy ROM.

PCI Latency Timer

Use this feature to set the latency Timer of each PCI device installed on a PCI bus. Select 64 to set the PCI latency to 64 PCI clock cycles. The options are 32, 64, 96, 128, 160, 192, 224 and 248.

Above 4G Decoding (Available if the system supports 64-bit PCI decoding)

Select Enabled to decode a PCI device that supports 64-bit in the space above 4G Address. The options are Enabled and Disabled.

PERR# Generation

Select Enabled to allow a PCI device to generate a PERR number for a PCI Bus Signal Error Event. The options are Enabled and Disabled.

SERR# Generation

Select Enabled to allow a PCI device to generate an SERR number for a PCI Bus Signal Error Event. The options are Enabled and Disabled.

Maximum Payload

Select Auto to allow the system BIOS to automatically set the maximum payload value for a PCI-E device to enhance system performance. The options are Auto, 128 Bytes and 256 Bytes.

Maximum Read Request

Select Auto to allow the system BIOS to automatically set the maximum Read Request size for a PCI-E device to enhance system performance. The options are Auto, 128 Bytes, 256 Bytes, 512 Bytes, 1024 Bytes, 2048 Bytes, and 4096 Bytes.

ASPM Support

This feature allows the user to set the Active State Power Management (ASPM) level for a PCI-E device. Select Force L0 to force all PCI-E links to operate at L0 state. Select Auto to allow the system BIOS to automatically set the ASPM level for the system. Select Disabled to disable ASPM support. The options are Disabled, Force L0, and Auto.

Warning: Enabling ASPM support may cause some PCI-E devices to fail!

4-16

Image 92
Contents X9DRD-iF X9DRD-LF Page About This Motherboard Manual OrganizationConventions Used in the Manual Asia-Pacific Contacting SupermicroEurope Table of Contents Vii Appendix a Bios Error Beep Codes Checklist OverviewX9DRD-iF Motherboard Image X9DRD-iF X9DRD-iF Motherboard LayoutX9DRD-iF X9DRD-iF Quick ReferenceConnectors X9DRD-iF/LF JumpersLED Indicators Juidb LAN1/LAN2 Ipmi LAN SP1Motherboard Features CPUSerialLink Connections Integrated IpmiSerial COM Port Super I/OCPU Monitoring Fan ControlX9DRD-iF Block Diagram System Block DiagramX9DRD-LF Block Diagram PCH C602 PCH C606Processor and Chipset Overview Special Features Recovery from AC Power LossEnvironmental Temperature Control PC Health MonitoringSlow Blinking LED for Suspend-State Indicator Acpi FeaturesPower Supply Management Engine ME Advanced Power ManagementSuper I/O Other Features Supported by the Wpcm BMC Controller Overview of the Nuvoton WPCM450 ControllerPage X9DRD-iF/LF Motherboard User’s Manual Battery Handling Standardized Warning StatementsPage Product Disposal 製品の廃棄Page Processor and Heatsink Installation Installing the LGA2011 ProcessorPress down on Load Lever Close 1st SocketSocket Keys CPU Keys Gently close Push down and lock Load plate Push downLock the lever Labelled OpenInstalling a Passive CPU Heatsink Screw#1Motherboard Mounting HolesRemoving the Heatsink Installing and Removing the Memory Modules Installing & Removing DIMMsRemoving Memory Modules Release TabsProcessors and their Corresponding Memory Modules Processor and Memory Module PopulationPopulating Udimm ECC/Non-ECC Memory Modules See the Note BelowIntel E5-2600 Series Processor Udimm Memory Support Data See the Note BelowPer Dimm Slots Per Channel Data See the Note Below 35V QRx48Rx4 QRx8Motherboard Installation Tools NeededLocation Mounting Holes An Important Note on PCI-E Slot PopulationInstalling the Motherboard Back Panel I/O Port Locations and Definitions Control Panel Connectors and I/O PortsBack Panel Connectors and I/O Ports Serial COM Ports Pin Definitions Serial PortsVideo Connection Universal Serial Bus USB Backplane USB 0/1, 2/3 Pin DefinitionsPin# Definition +5V PO+ Ground FP USB 4/5, 8/9, USB Pin DefinitionsEthernet Ports LAN Ports Pin DefinitionPin# Definition TD0+ Act LEDUnit Identifier Switch/UID LED Indicators UID SwitchPin# Definition Ground Button StatusJF1 Header Pins Front Control PanelNIC1 Link LED GroundPower LED Power LED Pin Definitions JF1Front Control Panel Pin Definitions NMI ButtonPin# Definition Vcc NIC 2 LED 11 Vcc NIC 1 LED NIC1/NIC2 LED IndicatorsPin# Definition 13 3.3V Standby HD Active Power Fail LED Overheat OH/Fan Fail/PWR FailOH/Fan Fail/ PWR Fail/BlueUID LED Pin Definitions JF1 OH/Fan Fail/PWR Fail LED Status Red LEDReset Button Power ButtonReset Button Pin Definitions JF1 Power Button Pin Definitions JF1Connecting Cables Power ConnectorsATX Power 24-pin Connector Pin Definitions 12V 8-pin PWR Con Nector Pin DefinitionsFan Headers Chassis IntrusionFan Header Pin Definitions Chassis Intrusion Pin DefinitionsPower LED/Speaker PWR LED Connector Pin DefinitionsSpeaker Connector Pin Settings Internal SpeakerTPM Header/Port Overheat LED/Fan FailTPM/Port 80 Header Pin Definitions Overheat LED Pin DefinitionsPower SMB I2C Connector Pin# Definition Clock Data PWR Fail Ground +3.3VIpmb Header Pin Definitions Pin# Definition Data Ground Clock No ConnectionDOM Power Connector X9DRD-iF Sgpio 1/2 & 3-SGPIO 1 Headers X9DRD-iFPin# Definition Ground Data Load Clock Pin# Definition +5V GroundPin# Definition +5V Standby Ground Wake-up Standby Power Header X9DRD-iFStandby PWR Pin Definitions Jumper Settings Glan Enable/DisableGlan Enable Jumper Settings Jumper Setting Definition Enabled default DisabledWatch Dog Enable/Disable Watch Dog Jumper SettingsJumper Setting Definition Pins Reset default Open DisabledVGA Enable BMC EnableVGA Enable Jumper Settings BMC Enable Jumper SettingsManagement Engine ME Recovery Manufacture Mode Select X9DRD-iFME Recovery ME Mode SelectI2C to PCI-E slots Jumper Settings I2C Bus to PCI-Exp. SlotsOnboard LED Indicators Glan LEDsIpmi Dedicated LAN LEDs Link LED Activity LEDBMC Heartbeat LED States Onboard Power LEDBMC Heartbeat LED Sata Ports/SCU Connectors SATA/SCU ConnectionsSerial ATA/SCU Pin Definitions Pin# Definition Ground TXP TXN RXN RXPNo Power Troubleshooting ProceduresBefore Power On No Video System Boot FailureLosing the System’s Setup Configuration Memory Errors When the System Becomes UnstableSystem becomes unstable before or during OS installation Technical Support Procedures Proper Battery Disposal Battery Installation Battery Removal and InstallationBattery Removal Frequently Asked Questions Returning Merchandise for Service Introduction Starting Bios Setup UtilityHow To Change the Configuration Data Main Setup Starting the Setup UtilitySystem Date System TimeSupermicro X9DRD-iF series Version Build DateAdvanced Setup Configurations Boot FeaturesSocket 1 CPU Information/Socket 2 CPU Information Power ConfigurationCPU Configuration CPU Speed 64-bitClock Spread Spectrum Hyper-threadingHardware Prefetcher Available when supported by the CPU DCU Streamer Prefetcher Available when supported by the CPULimit Cpuid Maximum Intel AES-NI CPU Power Management Configuration Power TechnologyEist Available when Power Technology is set to Custom Turbo Mode Available when Power Technology is set to CustomFactory Long Duration Power Limit Long Duration Power LimitRecommended Short Duration Power Energy PerformanceChipset Configuration North Bridge Integrated IO ConfigurationQPI Configuration Memory Mode Dram Rapl ModeMirroring SparingSouth Bridge Configuration SATA Configuration SCU Storage Control Unit Configuration PCIe/PCI/PnP Configuration Super IO Configuration Serial Port 1 ConfigurationSerial Port 2 Configuration Serial Port Console RedirectionConsole Redirection Settings ACPI Setting TPM Enable Status Intel TXT LT-SX Configuration Intel ME Subsystem ConfigurationBlink LEDs NIC ConfigurationLink Speed Change Smbios Event Log Settings Event LogsErasing Settings Erase Event Log When Log is FullSmbios Event Log Standard Settings Log System Boot Event View Smbios Event LogErasing Settings Erase SEL When SEL is FullIpmi System Event LogBMC Network Configuration Boot Delete Boot OptionsBoot Option #1/ Boot Option #2/ Boot Option #3 CSM SupportSecurity Administrator PasswordUser Password Save Changes and Reset Save & ExitDiscard Changes and Exit Save Options Save ChangesRestore Optimized Defaults Save as User DefaultsRestore User Defaults Boot OverrideX9DRD-iF/LF Motherboard User’s Manual Bios Error Beep Codes X9 Motherboard Bios Error Beep CodesX9DRD-iF/LF Motherboard User’s Manual Installing Software Programs Driver/Tool Installation Display ScreenConfiguring SuperDoctor SuperDoctor III Interface Display Screen Health InformationSuperDoctor III Interface Display Screen Remote Control X9DRD-iF/LF Motherboard User’s Manual