SUPER MICRO Computer X9DRD-LF Onboard LED Indicators, Glan LEDs, Ipmi Dedicated LAN LEDs

Page 66

X9DRD-iF/LF Motherboard User’s Manual

2-9 Onboard LED Indicators

GLAN LEDs

There are two GLAN ports on the moth- erboard. Each Gigabit Ethernet LAN port has two LEDs. The Yellow LED on the right indicates activity. The Link LED on the left side may be green, amber or off to indicate the speed of the connection. See the table on the right for more information.

Link LED

Activity LED

Rear View (when facing the rear side of the chassis)

GLAN Activity Indicator (Right)

LED Settings

Color Status Definition

 

Yellow

 

Flashing

Active

 

 

 

 

 

 

 

 

 

 

 

 

 

GLAN Speed/Link Indicator (Left)

 

 

LED Settings

 

 

 

LED Color

 

Definition

 

 

 

Off

 

No Connection or 10 Mbps

 

 

 

Green

 

100 Mbps

 

 

 

 

 

 

 

Amber

 

1 Gbps

 

 

 

 

 

 

 

 

 

 

 

 

IPMI Dedicated LAN LEDs

In addition to LAN 1/LAN 2, an IPMI Dedicated LAN is also located on the I/O Backplane of the motherboard. The amber LED on the right indicates activity, while the green LED on the left indicates the speed of the connection. See the table on the right for more information.

 

IPMI LAN

Link LED

Activity LED

IPMI LAN

IPMI LAN Link LED (Left) &

Activity LED (Right)

 

Color/State

Definition

 

 

 

Link (Left)

Green: Solid

100 Mbps

 

 

 

Activity (Right)

Amber: Blinking

Active

 

 

 

COM2

CPU1 SLOT3 PCI-E 3.0 X8

BMC CTRL

CPU1 SLOT4 PCI-E 3.0 X8

PCH

1

 

 

LEDM

 

LED3JUIDB

 

BMC

 

 

LAN CTRL

 

 

6

 

CPU1 SLOT5 PCI-E 3.0 X8

CPU2 SLOT6 PCI-E 3.0 X1

CPU2 SLOT7 PCI-E 3.0 X8

 

 

 

USB2/3

USB0/1

JIPMB1

VGA

 

 

 

 

 

 

 

FAN8

FAN7

LAN2

LAN1

IPMI_LAN

JPG1

 

LAN

 

 

JPB1

 

 

 

 

 

CTRL

JPL1

 

JI2C1

 

 

CLK CTRL

 

JI2C2

 

 

 

 

X9DRD-iF

Rev. 1.10

G1

H1

COM1 USB6

 

1

1

SP12 JD

 

 

1

JVRM I2C

JVRM I2C

JTPM

 

 

JPW4

 

F1

E1

A. LAN1/2 LEDs B. IPMI LAN LEDs

2

 

JPME

 

1

 

JPME

 

JWD1

 

A0ATI-S

A1ATI

 

-S

A2ATI-

A3ATI-S

S

 

I-SATA4

I-SATA5

SCU0

SCU1

SCU2

SCU3

 

 

JBT1

 

 

 

JRK1

 

JSD1

 

BIOS

 

C1

D1

B1

A1

CPU1

CPU2

JVR2

B

 

USB4/5

 

 

USB8/9

 

T-SGPIO1

 

T-SGPIO2

JSTBY1

1 JL

S-SGPIO1

FAN6

 

FAN5

FAN4

 

 

 

JBAT1

JOH1

JPW3

JPW1

A

 

 

 

 

 

 

JPW2

 

 

 

 

 

LED2

 

 

 

 

 

JPW5

 

 

FP

 

 

 

 

JVR1

FAN3

FAN2

FAN1

CTRL

1 JF

JPI2C1

 

 

2-40

Image 66
Contents X9DRD-iF X9DRD-LF Page About This Motherboard Manual OrganizationConventions Used in the Manual Contacting Supermicro EuropeAsia-Pacific Table of Contents Vii Appendix a Bios Error Beep Codes Checklist OverviewX9DRD-iF Motherboard Image X9DRD-iF X9DRD-iF Motherboard LayoutX9DRD-iF X9DRD-iF Quick ReferenceConnectors X9DRD-iF/LF JumpersLED Indicators Juidb LAN1/LAN2 Ipmi LAN SP1Motherboard Features CPUSerial COM Port SerialLink ConnectionsIntegrated Ipmi Super I/OCPU Monitoring Fan ControlX9DRD-iF Block Diagram System Block DiagramX9DRD-LF Block Diagram PCH C602 PCH C606Processor and Chipset Overview Environmental Temperature Control Special FeaturesRecovery from AC Power Loss PC Health MonitoringAcpi Features Power SupplySlow Blinking LED for Suspend-State Indicator Advanced Power Management Super I/OManagement Engine ME Other Features Supported by the Wpcm BMC Controller Overview of the Nuvoton WPCM450 ControllerPage X9DRD-iF/LF Motherboard User’s Manual Battery Handling Standardized Warning StatementsPage Product Disposal 製品の廃棄Page Processor and Heatsink Installation Installing the LGA2011 ProcessorPress down on Load Lever Close 1st SocketSocket Keys CPU Keys Lock the lever Gently close Push down and lock Load platePush down Labelled OpenMotherboard Installing a Passive CPU HeatsinkScrew#1 Mounting HolesRemoving the Heatsink Removing Memory Modules Installing and Removing the Memory ModulesInstalling & Removing DIMMs Release TabsProcessors and their Corresponding Memory Modules Processor and Memory Module PopulationPopulating Udimm ECC/Non-ECC Memory Modules See the Note BelowIntel E5-2600 Series Processor Udimm Memory Support Data See the Note Below8Rx4 Per Dimm Slots Per Channel Data See the NoteBelow 35V QRx4 QRx8Location Mounting Holes Motherboard InstallationTools Needed An Important Note on PCI-E Slot PopulationInstalling the Motherboard Control Panel Connectors and I/O Ports Back Panel Connectors and I/O PortsBack Panel I/O Port Locations and Definitions Serial Ports Video ConnectionSerial COM Ports Pin Definitions Pin# Definition +5V PO+ Ground Universal Serial Bus USBBackplane USB 0/1, 2/3 Pin Definitions FP USB 4/5, 8/9, USB Pin DefinitionsPin# Definition Ethernet PortsLAN Ports Pin Definition TD0+ Act LEDPin# Definition Ground Button Unit Identifier Switch/UID LED IndicatorsUID Switch StatusNIC1 Link LED JF1 Header PinsFront Control Panel GroundFront Control Panel Pin Definitions Power LEDPower LED Pin Definitions JF1 NMI ButtonNIC1/NIC2 LED Indicators Pin# Definition 13 3.3V Standby HD ActivePin# Definition Vcc NIC 2 LED 11 Vcc NIC 1 LED OH/Fan Fail/ PWR Fail/BlueUID LED Pin Definitions JF1 Power Fail LEDOverheat OH/Fan Fail/PWR Fail OH/Fan Fail/PWR Fail LED Status Red LEDReset Button Pin Definitions JF1 Reset ButtonPower Button Power Button Pin Definitions JF1ATX Power 24-pin Connector Pin Definitions Connecting CablesPower Connectors 12V 8-pin PWR Con Nector Pin DefinitionsFan Header Pin Definitions Fan HeadersChassis Intrusion Chassis Intrusion Pin DefinitionsSpeaker Connector Pin Settings Power LED/SpeakerPWR LED Connector Pin Definitions Internal SpeakerTPM/Port 80 Header Pin Definitions TPM Header/PortOverheat LED/Fan Fail Overheat LED Pin DefinitionsIpmb Header Pin Definitions Power SMB I2C ConnectorPin# Definition Clock Data PWR Fail Ground +3.3V Pin# Definition Data Ground Clock No ConnectionPin# Definition Ground Data Load Clock DOM Power Connector X9DRD-iFSgpio 1/2 & 3-SGPIO 1 Headers X9DRD-iF Pin# Definition +5V GroundStandby Power Header X9DRD-iF Standby PWR Pin DefinitionsPin# Definition +5V Standby Ground Wake-up Glan Enable Jumper Settings Jumper SettingsGlan Enable/Disable Jumper Setting Definition Enabled default DisabledJumper Setting Definition Pins Reset default Watch Dog Enable/DisableWatch Dog Jumper Settings Open DisabledVGA Enable Jumper Settings VGA EnableBMC Enable BMC Enable Jumper SettingsME Recovery Management Engine ME RecoveryManufacture Mode Select X9DRD-iF ME Mode SelectI2C to PCI-E slots Jumper Settings I2C Bus to PCI-Exp. SlotsIpmi Dedicated LAN LEDs Onboard LED IndicatorsGlan LEDs Link LED Activity LEDOnboard Power LED BMC Heartbeat LEDBMC Heartbeat LED States Serial ATA/SCU Pin Definitions Sata Ports/SCU ConnectorsSATA/SCU Connections Pin# Definition Ground TXP TXN RXN RXPTroubleshooting Procedures Before Power OnNo Power System Boot Failure Losing the System’s Setup ConfigurationNo Video Memory Errors When the System Becomes UnstableSystem becomes unstable before or during OS installation Technical Support Procedures Battery Removal and Installation Battery RemovalProper Battery Disposal Battery Installation Frequently Asked Questions Returning Merchandise for Service Starting Bios Setup Utility How To Change the Configuration DataIntroduction Main Setup Starting the Setup UtilitySupermicro X9DRD-iF series Version System DateSystem Time Build DateAdvanced Setup Configurations Boot FeaturesPower Configuration CPU ConfigurationSocket 1 CPU Information/Socket 2 CPU Information Clock Spread Spectrum CPU Speed64-bit Hyper-threadingLimit Cpuid Maximum Hardware Prefetcher Available when supported by the CPUDCU Streamer Prefetcher Available when supported by the CPU Intel AES-NIEist Available when Power Technology is set to Custom  CPU Power Management ConfigurationPower Technology Turbo Mode Available when Power Technology is set to CustomRecommended Short Duration Power Factory Long Duration Power LimitLong Duration Power Limit Energy PerformanceChipset Configuration North Bridge Integrated IO ConfigurationQPI Configuration Mirroring Memory ModeDram Rapl Mode SparingSouth Bridge Configuration SATA Configuration SCU Storage Control Unit Configuration PCIe/PCI/PnP Configuration Super IO Configuration Serial Port 1 ConfigurationSerial Port 2 Configuration Serial Port Console RedirectionConsole Redirection Settings ACPI Setting TPM Enable Status Intel TXT LT-SX Configuration Intel ME Subsystem ConfigurationNIC Configuration Link SpeedBlink LEDs Change Smbios Event Log Settings Event LogsSmbios Event Log Standard Settings Log System Boot Event Erasing Settings Erase Event LogWhen Log is Full View Smbios Event LogIpmi Erasing Settings Erase SELWhen SEL is Full System Event LogBMC Network Configuration Boot Option #1/ Boot Option #2/ Boot Option #3 BootDelete Boot Options CSM SupportAdministrator Password User PasswordSecurity Discard Changes and Exit Save Changes and ResetSave & Exit Save Options Save ChangesRestore User Defaults Restore Optimized DefaultsSave as User Defaults Boot OverrideX9DRD-iF/LF Motherboard User’s Manual Bios Error Beep Codes X9 Motherboard Bios Error Beep CodesX9DRD-iF/LF Motherboard User’s Manual Installing Software Programs Driver/Tool Installation Display ScreenConfiguring SuperDoctor SuperDoctor III Interface Display Screen Health InformationSuperDoctor III Interface Display Screen Remote Control X9DRD-iF/LF Motherboard User’s Manual