2.8.6.2Nonoperating vibration
The following table lists the maximum nonoperating vibration that the drive may experience without incurring physical damage or degradation in performance when subsequently put into operation.
0.25 G | |
|
|
5.0 Gs | |
|
|
2.9Acoustics
Drive acoustics are measured as overall
Note. For seek mode tests, the drive is placed in seek mode only. The number of seeks per second is defined by the following equation:
(Number of seeks per second = 0.4 / (average latency + average access time)
Table 4: | Operating acoustics |
| |
|
|
| |
Acoustic mode |
|
| |
|
|
|
|
Models |
| Idle | Operational |
|
|
| |
ST3400832ACE | 2.6 bels (typ) | 2.8 bels (typ) | |
|
| 2.8 bels (max) | 3.0 bels (max) |
|
|
| |
ST3300831ACE | 2.4 bels (typ) | 2.8 bels (typ) | |
ST3250823ACE | 2.7 bels (max) | 3.0 bels (max) | |
ST3200826ACE |
|
| |
|
|
|
|
2.10Electromagnetic immunity
When properly installed in a representative host system, the drive operates without errors or degradation in performance when subjected to the radio frequency (RF) environments defined in the following table:
Table 5: | Radio frequency environments |
|
| |
|
|
|
|
|
|
|
| Performance | Reference |
Test |
| Description | level | standard |
|
|
|
| |
Electrostatic discharge | Contact, HCP, VCP: ± 4 kV; Air: | B | EN | |
|
| ± 8 kV |
|
|
|
|
|
| |
Radiated RF immunity | 80 to 1,000 MHz, 3 V/m, | A | EN | |
|
| 80% AM with 1 kHz sine |
| ENV 50204: 95 |
|
| 900 MHz, 3 V/m, 50% pulse |
|
|
|
| modulation @ 200 Hz |
|
|
|
|
|
| |
Electrical fast transient | ± 1 kV on AC mains, ± 0.5 kV on | B | EN | |
|
| external I/O |
|
|
|
|
|
| |
Surge immunity | ± 1 kV differential, ± 2 kV com- | B | EN | |
|
| mon, AC mains |
|
|
|
|
|
| |
Conducted RF immunity | 150 kHz to 80 MHz, 3 Vrms, | A | EN | |
|
| 80% AM with 1 kHz sine |
|
|
|
|
|
|
|
DB35 Series Product Manual, Rev. B | 11 |