Seagate ST3450802SS Prefetch/multi-segmented cache control, Cache operation, Caching write data

Page 14

4.4Prefetch/multi-segmented cache control

The drive provides a prefetch (read look-ahead) and multi-segmented cache control algorithms that in many cases can enhance system performance. Cache refers to the drive buffer storage space when it is used in cache operations. To select this feature, the host sends the Mode Select command with the proper values in the applicable bytes in page 08h. Prefetch and cache operations are independent features from the standpoint that each is enabled and disabled independently using the Mode Select command; however, in actual opera- tion, the prefetch feature overlaps cache operation somewhat as described in sections 4.5.1 and 4.5.2.

All default cache and prefetch mode parameter values (Mode Page 08h) for standard OEM versions of this drive family are given in Section 9.3.2.1.

4.5Cache operation

Note. Refer to the SAS Interface Manual for more detail concerning the cache bits.

Of the 16 MB physical buffer space in the drive, approximately 13,000 kbytes can be used as a cache. The buf- fer is divided into logical segments from which data is read and to which data is written.

The drive keeps track of the logical block addresses of the data stored in each segment of the buffer. If the cache is enabled (see RCD bit in the SAS Interface Manual), data requested by the host with a read command is retrieved from the buffer, if possible, before any disk access is initiated. If cache operation is not enabled, the buffer is still used, but only as circular buffer segments during disk medium read operations (disregarding Prefetch operation for the moment). That is, the drive does not check in the buffer segments for the requested read data, but goes directly to the medium to retrieve it. The retrieved data merely passes through some buffer segment on the way to the host. All data transfers to the host are in accordance with buffer-full ratio rules. See the explanation provided with the information about Mode Page 02h (disconnect/reconnect control) in the SAS Interface Manual.

The following is a simplified description of the prefetch/cache operation:

Case A—read command is received and all of the requested logical blocks are already in the cache: 1. Drive transfers the requested logical blocks to the initiator.

Case B—A Read command requests data, and at least one requested logical block is not in any segment of the cache:

1.The drive fetches the requested logical blocks from the disk and transfers them into a segment, and then from there to the host in accordance with the Mode Select Disconnect/Reconnect parameters, page 02h.

2.If the prefetch feature is enabled, refer to section 4.5.2 for operation from this point.

Each cache segment is actually a self-contained circular buffer whose length is an integer number of logical blocks. The drive dynamically creates and removes segments based on the workload. The wrap-around capa- bility of the individual segments greatly enhances the cache’s overall performance.

Note. The size of each segment is not reported by Mode Sense command page 08h, bytes 14 and 15. The value 0XFFFF is always reported regardless of the actual size of the segment. Sending a size specification using the Mode Select command (bytes 14 and 15) does not set up a new segment size. If the STRICT bit in Mode page 00h (byte 2, bit 1) is set to one, the drive responds as it does for any attempt to change an unchangeable parameter.

4.5.1Caching write data

Write caching is a write operation by the drive that makes use of a drive buffer storage area where the data to be written to the medium is stored while the drive performs the Write command.

If read caching is enabled (RCD=0), then data written to the medium is retained in the cache to be made avail- able for future read cache hits. The same buffer space and segmentation is used as set up for read functions.

10

Cheetah NS 10K.2 SAS Product Manual, Rev. C

Image 14
Contents Cheetah NS 10K.2 SAS ST3600002SS ST3450802SSPage Contents Seagate Technology support services Defect and error managementInstallation Interface requirementsScope Electromagnetic compatibility Standards, compliance and reference documentsStandards Electromagnetic susceptibilityCompliance Reference documents General description Performance Standard featuresMedia description Reliability Programmable drive capacity Factory-installed options Formatted capacities Access time Performance characteristicsInternal drive characteristics Seek performanceStart/stop time Format command execution time minutesGeneral performance characteristics Caching write data Prefetch/multi-segmented cache controlCache operation Prefetch operation Recoverable Errors Reliability specificationsError rates Unrecoverable ErrorsPreventive maintenance Reliability and serviceInterface errors Hot plugging the drivePerformance impact 4 S.M.A.R.TControlling S.M.A.R.T Reporting controlThermal monitor Temperature Log Page 0Dh Parameter Code DescriptionPredictive failures Drive Self Test DSTDST failure definition ImplementationExtended test Function Code 010b Product warrantyShort test Function Code 001b Shipping DC power requirements Physical/electrical specificationsAC power requirements ST3600002SS DC power requirementsST3450802SS DC power requirements General DC power requirement notesCurrent profiles Power sequencingConducted noise immunity Typical ST3600002SS drive +5V and +12V current profiles ST3450802SS Power dissipationST3600002SS Temperature a. Operating Environmental limitsShock and vibration Relative humidityEffective altitude sea level a. Operating ShockPackage size Packaged/product weight Drop height Recommended mountingAcoustics Air cleanlinessVibration a. Operating-normal Corrosive environmentChina Restriction of Hazardous Substances RoHS Directive Mechanical specifications Physical dimensionsDrive error recovery procedures Defect and error managementDrive internal defects/errors 77.81 Media Pre-Scan SAS system errorsBackground Media Scan Deferred Auto-ReallocationIdle Read After Write Installation Drive orientationCooling Air flowDrive mounting GroundingSAS features Interface requirementsDual port support Scsi commands supported Commands supported by Cheetah NS 10K.2 SAS family drivesCommands supported by Cheetah NS 10K.2 SAS family drives Commands supported by Cheetah NS 10K.2 SAS family drives Commands supported by Cheetah NS 10K.2 SAS family drives Bytes Data hex Inquiry data2Mode Sense data Page 2.1 ST3600002SS Mode Sense data Mode Pages2.2 ST3450802SS Mode Sense data Supported Feature or condition Miscellaneous operating features and conditionsMiscellaneous features Miscellaneous statusSAS physical interface Datum B Physical characteristics Connector requirementsPin descriptions Pin Signal name Signal typeElectrical description SAS pin descriptionsSAS transmitters and receivers Signal characteristicsPower Ready LED OutGeneral interface characteristics LED drive signalDifferential signals Eye masks Eye masks overviewReceive eye mask X2OP 0, 5xadditional sinusoidal jitter X1OP Transmitter signal characteristics Signal characteristica Units 5Gb/s 0Gb/sMaximum allowable jitter Receiver signal characteristicsSignal characteristic Units 5Gb/s 0Gb/s 5Gb/s m, n 0Gb/s m, n Deterministic jitterq5Gb/sa 0Gb/sa Sinusoidal Deterministic Total Receiver jitter toleranceImpedance requirements Sheet 1 JitterhImpedance requirements Sheet 2 Electrical TxRx connections= -5, 437dB Shows the zero-length test load Additional information SAS-2 Specification complianceReceiver characteristics Technical Support Seagate Technology support servicesPresales Support Data Recovery Services Call Center Toll-free Direct dial Warranty ServiceData Recovery Services Authorized Service Centers Index Page SAS See also cooling Page Seagate Technology LLC