Perle Systems IOLINK-520 manual Event Logs

Page 57

Event Logs

Code

Description

033

Circuit out of order

034No circuit/channel available

035Destination unattainable

036Out of order

037Degraded service

038Network out of order

039Transit delay range cannot be achieved

040Throughput range cannot be achieved

041Temporary failure

042Switching equipment congestion

043Access information discarded

044Requested circuit/channel not available

045Preemption

046Precedence call blocked

047Resources unavailable, unspecified

049Quality of service unavailable

050Requested facility not subscribed

051Reverse charging not allowed

052Outgoing calls barred

053Outgoing calls barred within CUG

054Incoming calls barred

055Incoming calls barred within CUG

056Call waiting not subscribed

057Bearer capability not authorized

058Bearer capability not presently available

063Service or option not available, unspecified

065Bearer capability not implemented

066Channel type not implemented

067Transit network selection not implemented

068Message not implemented

069Requested facility not implemented

070Only restricted digital information bearer capability is available

079Service or option not implemented, unspecified

081Invalid call reference value

082Identified channel does not exist

083A suspended call exists, but this call identity does not

084Call identity in use

085No call suspended

086Call having the requested call identity has been cleared

087Destination address not member of CUG

088Incompatible destination

089Non-existent abbreviated address entry

090Destination address missing

091Invalid transit network selection

092Invalid facility parameter

093Mandatory information element is missing

095Invalid message, unspecified

096Mandatory information element is missing

097Message type non-existent or not implemented

098Message not compatible with call state or type non-existent or not implemented

099Information element non-existent or not implemented

100Invalid information element contents

101Message not compatible with call state

102Recovery on timer expiry

111Protocol error - unspecified

127Interworking - unspecified

A.14 IOLINK-PRO & 520 Reference Manual

Image 57
Contents Reference Manual IP Routing and the IOLINK-PRO & 520 Routers IOLINK-PRO & 520 RoutersARP-Address Resolution Protocol Proxy ARPComplete IP Connection IOLINK-PRO & 520 Reference Manua Protocol IP Header DetailsTime to live Header ChecksumOptions Icmp MessagesUnreachable RedirectTime and Mask server PingUpdate Mechanism RIP-Routing Information ProtocolRoute Tables IPX Addressing IPX Routing and The IOLINK-PRO & 520 RoutersNetwork Layer Addressing vs. MAC Addressing IPX Address FormatIPX Header Other IPX Header InformationService Advertisement Protocol Establishing an IPX ConnectionSAP Broadcasts Routing Information Protocol Server TypesSAP Requests RIP/X OperationBridging and the IOLINK-PRO & 520 Routers RIP/X RequestsRIP/X Metrics Station Address Learning Initial Bridging ProcessAddress Purging Aging TimerAging Exception Filled Address TableIolink Router Feature Definitions TelnetLink Compression Introduction Bandwidth On Demand WAN TopologiesPoint-to-Point MultipointTime of Day Connect Application Disaster Recovery Backup Link Operating Software UpgradesIsdn Single Active Link & Dual Active Link Iolink PRO & 520 Isdn Connection Management Wide Area Network Topologies SupportedCall Establishment Methods Auto-Call Time-of-Day Connections Isdn Connection ManagementManual Call Address ConnectCombination Connection ProcessProtocol Awareness Idle TimerSuspension Process Interesting TrafficTermination Process Session Keepalive MessagesIP Address Connect IP SpecificsSuspension of TCP/IP Sessions RIP-Routing Information ProtocolRIP/IPX and SAP/IPX IPX SpecificsSuspension of IPX Sessions IPX Serialization FramesPinout Information Module IdentificationLink Clocking Information Link Interfaces Reference ATL CSU/DSU Link Module InformationConsole Pinouts T1/E1 Module CSU/DSU ModuleRS232 Link Pinouts 24 & RS232C Link PinoutsDB15 Female DTE Direction Contact Circuits From Number 11 & X.21 Link PinoutsDB25 Female DTE Direction Contact Circuit From Number Name RS442 & RS530 Link PinoutsLink Pinouts DB25Number Name 11 RS232 Null-Modem Cable RS232 Null-Modem Cable Configuration12 V.35 Null-Modem Cable Null-Modem Cable Configuration13 RS530 Null-Modem Cable RS530 Null-Modem Cable Configuration14 RS530 to RS449 Conversion Cable RS530 To RS449 Conversion Cable15 V.11/X.21 Null-Modem Cable 11/X.21 Null-Modem Cable ConfigurationWAN Link Control-Signal Operation Event logs Appendix a Event LogsEvent Logs IOLINK-PRO & 520 Reference Manual A.3 Event Logs IOLINK-PRO & 520 Reference Manual A.5 Event Logs IOLINK-PRO & 520 Reference Manual A.7 Event Logs Alarm Logs Event Logs IOLINK-PRO & 520 Reference Manual A.11 Event Logs IOLINK-PRO & 520 Reference Manual A.13 Event Logs IOLINK-PRO & 520 Reference Manual A.15 Event Logs IOLINK-PRO & 520 Reference Manual A.17 Event Logs IOLINK-PRO & 520 Reference Manual A.19 PPP Security Logs Security MAC Address FilteringSecurity-Filter if Destination Programmable FilteringSecurity-Filter if Source Security-Forward if Destination Security-Forward if Source Programmable Filtering Pattern Filter Operators Bridge Pattern FilteringProtocol Discrimination Internet Protocol IP Protocol Type FieldFilter all IP Packets IP, and no moreFilter only TCP/IP Transport Control Protocol / Internet Protocol TCP/IPFilter all IP without TCP traffic Filter all except TCP/IPFilter all DEC Bandwidth ConservationEthernet Broadcasting Ethernet MulticastingGeneral Restrictions Internet AddressesEthernet Station Addresses Mask would be 6-010203040506&12-0800&23-06 Example Mask CombinationsIPX Router Pattern Filtering IP Router Pattern FilteringPage Appendix C Frame Formats Octet Locations on an IP Routed TCP/IP Frame IOLINK-PRO & 520 Reference Manual C.3