Omega C4EIT/-EIT manual iServer Management Page Alarm

Page 32

4.5.5.2 Management - Alarm

Figure 4.12 iServer MANAGEMENT Page – Alarm

Power Reset – Email – This option enables iServer to send an email when it is rebooted.

Power Reset – Trap – This option enables iServer to send a trap when it is rebooted.

IP Address Changed – Email – This option enables iServer to send an email when the iServer’s IP Address is changed.

IP Address Changed – Trap – This option enables iServer to send a trap when the iServer’s IP Address is changed.

iServer Accessed – Email – This option enables iServer to send an email when the iServer is accessed on Port 2000.

iServer Accessed – Trap – This option enables iServer to send a trap when the iServer is accessed on Port 2000.

Character 1,2 – Email – This option enables the iServer to send an email when the iServer receives on its serial port, the character specified in the field Character 1 or Character 2.

Character 1,2 – Trap – This option enables the iServer to send a trap when the iServer receives on its serial port, the character specified in the field Character 1 or Character 2.

26

Image 32
Contents User’s Guide Page Table of Contents Dhcp DNSList of Figures IServer Diagnostics Assigning an IP Address using iConnectAccessing the iServer’s Home ARP Commands and ResponsesData Transmission Characteristics RS485 ILog Error MessagesList of Tables Table K-1TIP Before You BeginPart Introduction EMC ConsiderationsAccessing Devices Over the Ethernet DescriptionPhysical Characteristics and Mounting Part HardwareNetwork Communication Interface Section Serial Communication Interfaces For Models with -C4EITWiring Master/Slave Units via RS485 Interface Half Duplex Hookup Pin# ISeriesRJ-45 Pinout Connecting iServer to PC/Hub/Switch/Router Network Communication Interfaces 1 10BASE-T RJ-45 PinoutEthernet MAC Address Part Network ConfigurationNetwork Protocols IP Address DhcpDNS Example C\Telnet 192.168.1.200 Part Operations Serial Interface Configuration Communication ProtocolCommand Prefix Letters LSB MSB Default IP Address Pinging the iServer from a DOS PromptAccess and Configuration Using a Web Browser IServer LoginOverview 4a iServer -C4EIT OverviewIServer Network Network IServer Serial Page RS485 Serial Port IServer Serial Page Network to Serial IServer Serial Page Packing Techniques IServer Serial Page Multi-Host Connection 10 iServer Configuration Page Ethernet Configuration Date and Time 11 iServer Management Page Email, Snmp Management Email Snmp 12 iServer Management Page Alarm AT&T 13 iServer Security 14 iServer Device Query Device Setup -C4EIT 15 iServer Device Setup Page RS485 -C4EIT16 iServer Device Parameters Page -C4EIT 17 iServer Device Setup Page -EIT Device Parameters -EIT 18 iServer Device Parameters Page -EITReadings Readings Device SetpointsTerminal 21 iServer TerminalSystem 22 iServer SystemDiagnostics 23 iServer Diagnostics Page 4.5.12.1 Diagnostics Serial PortDiagnostics Ethernet Port Diagnostics PingPart Specifications Serial Interface -C4EITTime-Lag, IEC 127-3 recognized Network Interface Serial InterfaceElectrical Safety EN61010-12001 PartMeasurement Category Transients Overvoltage Surge 1.2 / 50uS pulseAppendix Aglossary Appendix B IP Address Appendix C IP Netmask Mask Dotted Notation Mask Binary Mask Bits Class aClass B Class CDec Hex Binary Char No Parity No parity Appendix D Ascii ChartDec Hex Binary Appendix D Ascii Chart Continuation Ascii Control CodesDec Hex Ctrl Key Definition Dec Hex Ctrl Key Definition Char EquivFigure E-1 Assigning an IP Address using iConnect Appendix E IConnect SoftwareFigure E-2 Accessing the iServer’s Home Appendix F HTTPget Program Communication interface skip for embedded ethernet -EIT\iServerhttpget -r -S *02X01\r Network read timeout \iServerhttpget -r -S *02X01\r 192.168.1.2002000Appendix G ARP Program Arp -g fi Same as arp -a192.168.1.96 Admin Port Appendix H Telnet SetupISeries? Figure H-3 Telnet Setup iServer Help Figure I-1a Serial Tunneling iSeries -C4EIT Figure I-1b Serial Tunneling iSeries -EITFigure I-2 Device-to-Device Communication Remote iSeries -EIT/-C4EITLocal iSeries -EIT/-C4EIT Figure I-3 Serial Multi-Host Connection -C4EIT Tunneling Troubleshooting Appendix J IPORT IPORT, COM Port RedirectorIPORT Overview Figure J-2a Redirect Serial Connection Figure J-3 iPORT Main Window IPORT Configurations Figure K-1 iLog Software Logging Data for an iSeries Appendix K ILog SoftwareWireless Devices Table K-1 iLog Excel ApplicationsNetworked Product ILOG File Alternate ISeriesTable K-2 iLog Error Messages Error # Description Page Page Page Page Page WARRANTY/DISCLAIMER Shop on line at omega.com