Omega C4EIT/-EIT manual Part, Electrical Safety EN61010-12001, Measurement Category, Fcc

Page 48

PART 7

APPROVALS INFORMATION

7.1CE APPROVALS INFORMATION

This product conforms to the EMC directive 89/336/EEC amended by 93/68/EEC, and with the European Low Voltage Directive 72/23/EEC.

Electrical Safety EN61010-1:2001

Safety requirements for electrical equipment for measurement, control and laboratory.

Double Insulation

 

Pollution Degree 2

 

Dielectric withstand Test per 1 min

 

Power to Input/Output:

2300 Vac (3250 Vdc)

Power to Input/Output:

1500 Vac (2120 Vdc)

 

 

(Low Voltage dc Power Option*)

Power to Relays/SSR Output:

2300 Vac (3250 Vdc)

Ethernet to Inputs:

1500 Vac (2120 Vdc)

Isolated RS232 to Inputs:

500 Vac (720 Vdc)

Isolated Analog to Inputs:

500 Vac (720 Vdc)

Analog/Pulse to Inputs:

No Isolation

Measurement Category I

Category I are measurements performed on circuits not directly connected to the Mains Supply (power). Maximum Line-to-Neutral working voltage is 50 Vac/dc. This unit should not be used in Measurement Categories II, III, IV.

Transients Overvoltage Surge (1.2 / 50uS pulse)

Input Power:

2500 V

Input Power:

1500 V

 

 

(Low Voltage dc Power Option*)

Ethernet:

1500 V

Input/Output Signals:

500 V

Note: *Units configured for external low power dc voltage, 20-36 Vdc

EMC:

EN 61326:2006, Class B Emissions EN 61326:2006, Immunity

EN 55022:2006 + A1:2007, Class B, (CISPR 22 + A1:2005) - Emissions Ethernet EN 55024:1998 + A1:2001 + A2:2003 - Immunity Ethernet

EN 61000-3-2:2006 AC harmonics Current Emissions EN 61000-3-3:2008 Voltage Fluctuations and Flickers

Note: **I/O signal and control lines require shielded cables and these cables must be located on conductive cable trays or in conduits. Furthermore, the length of these cables should not exceed 30 meters

Refer to the EMC and Safety installation considerations (Guidelines) of this manual for additional information.

7.2FCC

This device complies with Part 15, Subpart B, Class B of the FCC rules.

42

Image 48
Contents User’s Guide Page Table of Contents Dhcp DNSList of Figures IServer Diagnostics Assigning an IP Address using iConnectAccessing the iServer’s Home ARP Commands and ResponsesData Transmission Characteristics RS485 ILog Error MessagesList of Tables Table K-1TIP Before You BeginPart Introduction EMC ConsiderationsAccessing Devices Over the Ethernet DescriptionPhysical Characteristics and Mounting Part HardwareNetwork Communication Interface Section Serial Communication Interfaces For Models with -C4EITWiring Master/Slave Units via RS485 Interface Half Duplex Hookup Pin# ISeriesRJ-45 Pinout Connecting iServer to PC/Hub/Switch/Router Network Communication Interfaces 1 10BASE-T RJ-45 PinoutPart Network Configuration Network ProtocolsEthernet MAC Address Dhcp DNSIP Address Example C\Telnet 192.168.1.200 Serial Interface Configuration Communication Protocol Command Prefix LettersPart Operations LSB MSB Default IP Address Pinging the iServer from a DOS PromptAccess and Configuration Using a Web Browser IServer LoginOverview 4a iServer -C4EIT OverviewIServer Network Network IServer Serial Page RS485 Serial Port IServer Serial Page Network to Serial IServer Serial Page Packing Techniques IServer Serial Page Multi-Host Connection 10 iServer Configuration Page Ethernet Configuration Date and Time 11 iServer Management Page Email, Snmp Management Email Snmp 12 iServer Management Page Alarm AT&T 13 iServer Security 14 iServer Device Query Device Setup -C4EIT 15 iServer Device Setup Page RS485 -C4EIT16 iServer Device Parameters Page -C4EIT 17 iServer Device Setup Page -EIT Device Parameters -EIT 18 iServer Device Parameters Page -EITReadings Readings Device SetpointsTerminal 21 iServer TerminalSystem 22 iServer SystemDiagnostics 23 iServer Diagnostics Page 4.5.12.1 Diagnostics Serial PortDiagnostics Ethernet Port Diagnostics PingPart Specifications Serial Interface -C4EITTime-Lag, IEC 127-3 recognized Network Interface Serial InterfaceElectrical Safety EN61010-12001 PartMeasurement Category Transients Overvoltage Surge 1.2 / 50uS pulseAppendix Aglossary Appendix B IP Address Appendix C IP Netmask Mask Dotted Notation Mask Binary Mask Bits Class aClass B Class CAppendix D Ascii Chart Dec Hex BinaryDec Hex Binary Char No Parity No parity Appendix D Ascii Chart Continuation Ascii Control CodesDec Hex Ctrl Key Definition Dec Hex Ctrl Key Definition Char EquivFigure E-1 Assigning an IP Address using iConnect Appendix E IConnect SoftwareFigure E-2 Accessing the iServer’s Home Appendix F HTTPget Program Communication interface skip for embedded ethernet -EIT\iServerhttpget -r -S *02X01\r Network read timeout \iServerhttpget -r -S *02X01\r 192.168.1.2002000Arp -g fi Same as arp -a 192.168.1.96Appendix G ARP Program Admin Port Appendix H Telnet SetupISeries? Figure H-3 Telnet Setup iServer Help Figure I-1a Serial Tunneling iSeries -C4EIT Figure I-1b Serial Tunneling iSeries -EITFigure I-2 Device-to-Device Communication Remote iSeries -EIT/-C4EITLocal iSeries -EIT/-C4EIT Figure I-3 Serial Multi-Host Connection -C4EIT Tunneling Troubleshooting IPORT, COM Port Redirector IPORT OverviewAppendix J IPORT Figure J-2a Redirect Serial Connection Figure J-3 iPORT Main Window IPORT Configurations Figure K-1 iLog Software Logging Data for an iSeries Appendix K ILog SoftwareWireless Devices Table K-1 iLog Excel ApplicationsNetworked Product ILOG File Alternate ISeriesTable K-2 iLog Error Messages Error # Description Page Page Page Page Page WARRANTY/DISCLAIMER Shop on line at omega.com