Omnitron Systems Technology 10/100M user manual Setting SNMPv1/v2c Read and Write Community Names

Page 17

SNMP Preferences Screen

 

iConverter, Serial Agent

 

Chassis Number

= 1

SNMP Engine ID 80001CAE03000687003B19

1: sysContact

 

Omnitron (949) 250-6510

 

 

2: sysLocation

 

Irvine, CA USA

 

 

3: SNMP Writes

 

Enabled

 

 

 

SNMP v1/v2c -------------------------------------------------------------------

 

 

 

 

4: Read Community

*****

 

 

 

5: Write Community

*****

 

 

 

6: Agent

 

Enabled

 

 

 

SNMP V3 -----------------------------------------------------------------------

 

 

 

 

7: Agent

 

Enabled

 

 

 

8: User 1 name (read only)

guest

 

 

 

9: User 2 name (read/write)

admin

 

 

 

10: User 1 Security

noAuthNoPriv 13: User 2 Security

noAuthNoPriv

11: User 1 Privacy pwd

*****

14: User 2 Privacy pwd

*****

12: User 1 Authen. pwd

*****

15: User 2 Authen. pwd

*****

Traps Hosts -------------------------------------------------------------------

 

 

 

 

16: Address 1

255.255.255.255

20: Address 5

255.255.255.255

17: Address 2

255.255.255.255

21: Address 6

255.255.255.255

18: Address 3

255.255.255.255

22: Address 7

255.255.255.255

19: Address 4

255.255.255.255

23: Address 8

255.255.255.255

Enter Choice, Management Options Screen(0), (H)elp, E(x)it >

3.4.2.1Setting SNMPv1/v2c Read and Write Community Names

The 10/100M is shipped from the factory with the SNMP agent enabled with the default SNMP Read and Write Community name as “public”. See Section 3.4 for all factory default settings.

The SNMP Read Community Name is necessary for reading data from the 10/100M. The name can be any 1-32 character alphanumeric string. To set the SNMP Read Community Name, select 4 at the SNMP Preferences screen, press <ENTER> and then follow the screen prompts.

The SNMP Write Community Name is necessary for writing data to the 10/100M. The name can be any 1-32 character alphanumeric string. To set the SNMP Write Community Name, select 5 at the SNMP Preferences screen, press <ENTER> and then follow the screen prompts.

To save the new values, select 0 and press <ENTER> to return to the Management Options screen, then select 6 and press <ENTER> to Save Preference Changes.

3.4.2.2Setting SNMPv3 Parameters

SNMPv3 implements a security model that provides for message integrity, authentication, and encryption.

Authentication for SNMPv3 is provided through a unique User Name and Authentication Password for each access level.

Two access levels or accounts are available; Read-Only Level (User 1) and Read and Write Level (User 2). User 1 is allowed to request information from the module. User 2 is allowed to request information from and set configuration to the module. To set the User 1 name, select 8 at the SNMP Preferences screen, press <ENTER> and then follow the screen prompts. To set the User 2 name, select 9 at the SNMP Preferences screen, press <ENTER> and then follow the screen prompts. The 10/100M is shipped with default values pre-assigned. See Section 3.4 for all factory default settings.

The module supports the three levels of Authentication and Encryption (Security Levels) for User 1 and User 2; noAuthNoPriv, authNoPriv and authPriv. noAuthNoPriv uses username for authentication,

Page 17

Image 17
Contents Standalone and PLUG-IN Module Table of Contents Overview Port Structure Installation Procedure Configuring DIP-SWITCHES 1.2 SW2 Fiber Full/Half-Duplex FDX/HDX 1.5 SW5 UTP Full/Half Duplex FDX/HDX These DIP-switches are for factory use only Installing PLUG-IN Modules and Connecting Cables Passwords Management Options screen will be displayed Setting IP and Control Preferences Setting the Chassis Number and Name Setting 10/100M Passwords Setting Snmp Preferences Setting SNMPv1/v2c Read and Write Community Names Setting the Snmp Trap IP Host Addresses Vlan ID Page Access the 10/100M Remotely Updating the 10/100M Firmware via the Serial Console Port Verify Operation NMM Detailed Module Configuration8919-0 10/100M LED UTP HDX UTP FDXModule Management Mode Port Configuration Port Access SFP Information A167EC500000 4 802.3ah Parameters OUI UTP Port Vlan Page Tagged Vlan BP a BP BPvid Vlan Table is Empty Vlan ID VIDUTP BP a BP B Vlan ID +1 Vlan ID CNode Loopback To refresh the Port Statistic screen, press Enter Cable Types 10/100M SpecificationsPossible Causes Troubleshooting GuidePossible Causes Limitation of Warranty Warranty