Omnitron Systems Technology 10/100M user manual Setting the Chassis Number and Name

Page 14

Management Options

iConverter, Serial Agent

Network Management

1:Chassis and Module Management

2:Set Module Identifier

Management Module Preferences

3:IP and Control Preferences

4:SNMP Preferences

5:Abandon Preference Changes

6:Save Preference Changes

7:Restore to Factory Defaults

8:Restart Management Module

9:Other Networking Features

Management Module Maintenance

10:Firmware Update

11:Set Date/Time

IP Address

= 192.168.1.220

 

Chassis Number = 1

 

Enter Choice, (H)elp, E(x)it > 9

 

 

 

 

 

Other Networking Features Screen

iConverter, Serial Agent

1:

Enable/Disable DHCP Client

Disabled

2:

Enable/Disable Keep Alive Trap

Disabled

3:

Keep Alive Trap interval (10-600 secs)

10

4:

Enable/Disable SW1 Switch Block

Enabled

5:

Serial Baud Rate

57600 bps

6:

Enable/Disable VLAN Support

Disabled

7:

VLAN ID (0-4095)

2

8:

VLAN Priority (0-7)

7

Enter Choice, Management Options Screen(0), (H)elp, E(x)it >

To enable DHCP client, select 1 at the Other Networking Features screen and follow the screen prompts to enable DHCP.

To save the new values, select 0 and press <ENTER> to return to the Management Options screen, then select 6 and press <ENTER> to Save Preference Changes.

3.4.1.3Setting the Chassis Number and Name

A Chassis Name, or sysName, can be assigned for identification of the 10/100M in the SNMP client. The name can be any 1-32 character alphanumeric string.

The Chassis Number can remain as 1 (factory default) when the 10/100M is installed without an iConverter NMM in the same chassis. When the 10/100M is installed in the same chassis as an NMM, then the 10/100M must be set to the Chassis Number of the NMM.

To set the Chassis Number, select 4 at the IP and Control Preferences screen, press <ENTER> and follow the instructions to enter the chassis number.

To set the Chassis Name, select 5 at the IP and Control Preferences screen, press <ENTER> and follow the instructions to enter the chassis name.

Page 14

Image 14
Contents Standalone and PLUG-IN Module Table of Contents Overview Port Structure Installation Procedure Configuring DIP-SWITCHES 1.2 SW2 Fiber Full/Half-Duplex FDX/HDX 1.5 SW5 UTP Full/Half Duplex FDX/HDX These DIP-switches are for factory use only Installing PLUG-IN Modules and Connecting Cables Passwords Management Options screen will be displayed Setting IP and Control Preferences Setting the Chassis Number and Name Setting 10/100M Passwords Setting Snmp Preferences Setting SNMPv1/v2c Read and Write Community Names Setting the Snmp Trap IP Host Addresses Vlan ID Page Access the 10/100M Remotely Updating the 10/100M Firmware via the Serial Console Port Verify Operation Detailed Module Configuration NMM8919-0 10/100M UTP HDX UTP FDX LEDModule Management Mode Port Configuration Port Access SFP Information A167EC500000 4 802.3ah Parameters OUI UTP Port Vlan Page Tagged Vlan BP a BP BPvid Vlan Table is Empty Vlan ID VIDUTP BP a BP B Vlan ID +1 Vlan ID CNode Loopback To refresh the Port Statistic screen, press Enter 10/100M Specifications Cable TypesTroubleshooting Guide Possible CausesPossible Causes Warranty Limitation of Warranty