Omnitron Systems Technology 10/100M user manual Utp Hdx Utp Fdx, Led

Page 26

Module -

iConverter 10/100M

iConverter, Serial Agent

 

Identifier -

 

 

 

 

 

 

 

Chassis Number

=

1

Switch ON Condition

OFF Condition

H/W

Actual

Slot Number

=

1

1: Pause Enabled

Pause Disabled

Off

Off

Model Number

=

8919-0

2: Fiber HDX

Fiber FDX

Off

Off

 

 

 

 

3: UTP Manual

UTP Auto-Neg

Off

Off

Serial Number

= xxxxxxxx

4: UTP 10 Mbps

UTP 100 Mbps

Off

Off

Manufacturing Date = xxxxxxxx

5: UTP HDX

UTP FDX

Off

Off

Product Revision

= x

6: Link Propagate

Link Segment

Off

Off

Software Revision

= xx

7: Remote Fault

Normal

Off

Off

 

 

 

 

8: Symm Fault Det

Normal

Off

Off

LED

 

 

 

9: BP A Enabled

BP A Disabled

On

On

1: Power

 

= On

10: BP B Enabled

BP B Disabled

On

On

2: Power Supply 1

= Off

11: Not Available

 

 

 

 

3: Power Supply 2

= Off

12: Slave Only

Master/Slave

Off

Off

4: Power Supply 3

= Off

13: Not Available

 

 

 

 

5: Fiber Link

= Off

14: Not Available

 

 

 

 

6: BP Master

= On

15: Not Available

 

 

 

 

7: UTP 10

Link

= Off

16: Not Available

 

 

 

 

8: UTP 100 Link

= Off

OAM settings:

 

 

 

 

9: UTP FDX

= Off

17: IP Protocol State

On

 

 

 

 

 

 

18: Management Mode

Secure OAM

 

 

Toggle Switch(1-16), (I)dentifier, (R)eset, (H)elp, (P)ortStat, Port(C)tl >

 

 

 

 

 

 

 

 

 

 

The Module configuration screen provides general information concerning the configuration and status of the module. The screen displays the model and serial numbers, hardware and software revisions, as well as the condition of the LEDs and DIP-switches. The DIP-switches can be re-configured (options 1 - 10, 12) without removing the module from the chassis. Select the appropriate option to change the DIP-switch setting. Selecting DIP-switch options 1 - 10 and 12, will cause the selection to change states under the ‘Actual’ heading.

NOTE: The Plug-In Module configuration screen is shown. The standalone Module configuration screen will display LED 2, 3, 4, and 6 and DIP-switches 9, 10 and 12 as NOT AVAILABLE.

Page 26

Image 26
Contents Standalone and PLUG-IN Module Table of Contents Overview Port Structure Installation Procedure Configuring DIP-SWITCHES 1.2 SW2 Fiber Full/Half-Duplex FDX/HDX 1.5 SW5 UTP Full/Half Duplex FDX/HDX These DIP-switches are for factory use only Installing PLUG-IN Modules and Connecting Cables Passwords Management Options screen will be displayed Setting IP and Control Preferences Setting the Chassis Number and Name Setting 10/100M Passwords Setting Snmp Preferences Setting SNMPv1/v2c Read and Write Community Names Setting the Snmp Trap IP Host Addresses Vlan ID Page Access the 10/100M Remotely Updating the 10/100M Firmware via the Serial Console Port Verify Operation Detailed Module Configuration NMM8919-0 10/100M UTP HDX UTP FDX LEDModule Management Mode Port Configuration Port Access SFP Information A167EC500000 4 802.3ah Parameters OUI UTP Port Vlan Page Tagged Vlan BP a BP BPvid Vlan Table is Empty Vlan ID VIDUTP BP a BP B Vlan ID +1 Vlan ID CNode Loopback To refresh the Port Statistic screen, press Enter 10/100M Specifications Cable TypesTroubleshooting Guide Possible CausesPossible Causes Warranty Limitation of Warranty