Omnitron Systems Technology 10/100M user manual Port Access

Page 29

4.3.1Port Access

The Port Access option allows the ports to be disabled/enabled while maintaining the port configuration and network link

To configure Port Access, select option 1 for the Fiber port and option 2 for the UTP port from the Port configuration screen.

4.3.2Bandwidth Control

The 10/100M Bandwidth Control is accessed by selecting options 21 - 24 or 14 - 17 depending on the module type; plug-in or standalone.

The 10/100M provides separate ingress and egress rate control on each port.

Ingress values will be displayed when the option is selected. Values of 128Kbps, 256Kbps, 512Kbps, 1Mbps, 2Mbps, 4Mbps, 8Mbps and Full bandwidth are available.

Egress values will be displayed when the option is selected. Values of 128Kbps, 256Kbps, 512Kbps, 1Mbps, 2Mbps, 4Mbps, 8Mbps and Full bandwidth are available.

Module - iConverter 10/100M

 

 

iConverter, Serial Agent

Identifier -

 

 

 

 

 

 

 

Chassis Number

= 1

Port VLAN Path Setup

 

 

Slot Number

= 11

----------------------------------

 

 

 

 

Model Number

= 8919-0

11: Fiber to UTP

Enable

On

 

 

12: Fiber to BP A

Enable

On

Port Access Control Setup

13: Fiber to BP B

Enable

On

----------------------------------

14: UTP to BP A

Enable

On

1: Fiber Enable

On

15: UTP to BP B

Enable

On

2: UTP Enable

On

16: BP A

to BP B

Enable

On

 

 

17: Fiber to Mngmnt

Enable

On

Enhanced Features

18: UTP to Mngmnt

Enable

On

----------------------------------

19: BP A

to Mngmnt

Enable

On

3: 802.1Q Processing Enable Off

20: BP B

to Mngmnt

Enable

On

4: Configure Tag VLAN Control

 

 

 

 

 

 

5: Configure VLAN Membership

Bandwidth Control

 

 

6: Save TAG VLAN parameters

--------------------------------

 

 

 

 

7: Configure 802.3ah parameters

21: Ingress rate Fiber

No Limit

8: Configure 802.3ah events

22: Egress

rate Fiber

No Limit

9: SFP Information

 

23: Ingress rate UTP

 

No Limit

10: cNode Loopback

 

24: Egress

rate UTP

 

No Limit

Enter Choice, Previous Screen(0), (H)elp, E(x)it >21 New Rate (0= No Limit, 1=128Kbps, 2=256Kbps, 3=512Kbps,

4=1Mbps, 5=2Mbps, 6=4Mbps, 7=8Mbps) > 0

Page 29

Image 29
Contents Standalone and PLUG-IN Module Table of Contents Overview Port Structure Installation Procedure Configuring DIP-SWITCHES 1.2 SW2 Fiber Full/Half-Duplex FDX/HDX 1.5 SW5 UTP Full/Half Duplex FDX/HDX These DIP-switches are for factory use only Installing PLUG-IN Modules and Connecting Cables Passwords Management Options screen will be displayed Setting IP and Control Preferences Setting the Chassis Number and Name Setting 10/100M Passwords Setting Snmp Preferences Setting SNMPv1/v2c Read and Write Community Names Setting the Snmp Trap IP Host Addresses Vlan ID Page Access the 10/100M Remotely Updating the 10/100M Firmware via the Serial Console Port Verify Operation NMM Detailed Module Configuration8919-0 10/100M LED UTP HDX UTP FDXModule Management Mode Port Configuration Port Access SFP Information A167EC500000 4 802.3ah Parameters OUI UTP Port Vlan Page Tagged Vlan BP a BP BPvid Vlan Table is Empty Vlan ID VIDUTP BP a BP B Vlan ID +1 Vlan ID CNode Loopback To refresh the Port Statistic screen, press Enter Cable Types 10/100M SpecificationsPossible Causes Troubleshooting GuidePossible Causes Limitation of Warranty Warranty