Omnitron Systems Technology 10/100M user manual Bp B, Pvid, BP a

Page 38

Tagged VLAN is accessed by selecting option 4 from the Port configuration screen. The Tag VLAN Control screen will be displayed.

Tag VLAN Control - iConverter 10/100M

 

iConverter, Serial Agent

 

Identifier -

 

 

 

 

 

Chassis Number = 1

Slot Number = 1

Model Number = 8919-0

 

Fiber1: Port Priority (PRI)

0

BP B

16: Port Priority (PRI) 0

 

 

2: PVID (Port VLAN ID

2

 

17: PVID (Port VLAN ID)

2

 

3: Tagged Packets Use

PVID

 

18: Tagged Packets Use

PVID

 

4: Ingress Security

Low

 

19: Ingress Security

Low

 

5: Egress Policy

 

Pass

 

20: Egress Policy

Pass

UTP

6: Port Priority (PRI)

0

Mngmnt

21: Port Priority (PRI)

0

 

7: PVID (Port VLAN ID)

2

 

22: PVID (Port VLAN ID)

2

 

8: Tagged Packets Use

PVID

 

23: Tagged Packets Use

PVID

 

9: Ingress Security

Low

 

24: Ingress Security

Low

 

10: Egress Policy

 

Pass

 

25: Egress Policy

Pass

BP A

11: Port Priority (PRI)

0

 

 

 

 

12: PVID (Port VLAN ID)

2

 

 

 

 

13: Tagged Packets Use

PVID

 

 

 

 

14: Ingress Security

Low

 

 

 

 

15: Egress Policy

 

Pass

 

 

 

Enter Choice, Previous Screen(0), (H)elp, E(x)it >

 

 

 

 

 

 

 

 

 

Tag VLAN Control - iConverter 10/100M

 

iConverter, Serial Agent

 

Identifier -

 

 

 

 

 

Chassis Number = 1

Slot Number = 1

Model Number = 8919-0

 

Fiber

1: Port Priority (PRI)

0

 

 

 

 

2: PVID (Port VLAN ID)

2

 

 

 

 

3: Tagged Packets Use

PVID

 

 

 

4: Ingress Security

Low

 

 

 

5: Egress Policy

Pass

 

 

UTP

6: Port Priority (PRI)

0

 

 

 

 

7: PVID (Port VLAN ID)

2

 

 

 

 

8: Tagged Packets Use

PVID

 

 

 

9: Ingress Security

Low

 

 

 

10: Egress Policy

Pass

 

 

Mngmnt 11: Port Priority (PRI)

0

 

 

 

 

12: PVID (Port VLAN ID)

2

 

 

 

 

13: Tagged Packets Use

PVID

 

 

 

14: Ingress Security

Low

 

 

 

15: Egress Policy

Pass

 

 

Enter Choice, Previous Screen(0), (H)elp, E(x)it >

Page 38

Image 38
Contents Standalone and PLUG-IN Module Table of Contents Overview Port Structure Installation Procedure Configuring DIP-SWITCHES 1.2 SW2 Fiber Full/Half-Duplex FDX/HDX 1.5 SW5 UTP Full/Half Duplex FDX/HDX These DIP-switches are for factory use only Installing PLUG-IN Modules and Connecting Cables Passwords Management Options screen will be displayed Setting IP and Control Preferences Setting the Chassis Number and Name Setting 10/100M Passwords Setting Snmp Preferences Setting SNMPv1/v2c Read and Write Community Names Setting the Snmp Trap IP Host Addresses Vlan ID Page Access the 10/100M Remotely Updating the 10/100M Firmware via the Serial Console Port Verify Operation Detailed Module Configuration NMM8919-0 10/100M UTP HDX UTP FDX LEDModule Management Mode Port Configuration Port Access SFP Information A167EC500000 4 802.3ah Parameters OUI UTP Port Vlan Page Tagged Vlan BP a BP BPvid Vlan Table is Empty Vlan ID VIDUTP BP a BP B Vlan ID +1 Vlan ID CNode Loopback To refresh the Port Statistic screen, press Enter 10/100M Specifications Cable TypesTroubleshooting Guide Possible CausesPossible Causes Warranty Limitation of Warranty