Remote Connection Authentication Settings

Chapter 5 - RouteFinder Manager

Remote Connection Authentication Settings

When you select Allow Remote Dial-in, you must determine the method that remote users must use to be authenticated on your system. If you choose the PAP or CHAP authentication protocol, you must select Use Local Settings, Use Local Client List or Use RADIUS Server authentication.

Use Local Setting

You may create a Remote User Name and Remote Password to log in to the system. All users must type the same user name and password that you specify.

Use Local Client List

The Local Client list is a list of all User Names and Passwords that can access your network from a remote site. When a remote user dials in to the RF802EW, the user’s access profile information (user name, password, callback status, etc.) is validated by checking the user information in this list. The RF802EW can include up to 64 users in the Local Client list. Click Local Client List to add your remote users.

Important: The RF802EW is set up with a default user of guest which requires no password. For security reasons, either delete the user ID guest or provide it with a password.

Client Information

For each new remote user added to the system, enter the following information:

User Name

Specify a user name with a maximum of 16 characters.

Password

Specify the password corresponding to the user name. Passwords are limited to 16 characters.

Password Verification

Verify the password by re-entering the user password in the box provided.

Callback Type

The callback feature provides an added level of security to your dial in system. A remote client dials in to the network and then disconnects. The RF802EW then calls the client back. The feature can be implemented using no callback, fixed callback, or variable callback.

No Callback

The RouteFinder does not perform a callback function. This is the default setting.

Fixed Callback

The RouteFinder will connect to the client by dialing the number specified in the Your TelNumber box.

Variable Callback

This option allows the remote client to specify the phone number the RouteFinder should callback each time a dial up connection is established.

38

Image 38
Contents Model RF802EW Wireless Router/Access Point User GuideWireless Router/Access Point User GuideRecord of Revisions PATENTSChapter 1 - Introduction Chapter 2 - Hardware InstallationChapter 3 - Software Installation and Configuration Chapter 5 - RouteFinder ManagerChapter 10 - Service, Warranty Chapter 8 LAN-to-LAN SettingsChapter 9 - Troubleshooting and Technical SupportWINIPCFG and IPCONFIG IndexChapter 1 - Introduction The RouteFinder RF802EW IntroductionChapter 1 - Introduction Front Panel Power 5VDCReset Back PanelTypical Applications Connecting a Remote Site via Cable ModemConnecting a Local Site to the Internet KernalAccess Point SpecificationsWireless Power OutputChapter 2 - Hardware Installation Chapter 2 - Hardware Installation Hardware InstallationSafety Unpacking the RF802EWCabling Cabling the RouteFinder RF802EWChapter 3 - Software Installation and Configuration Chapter 3 - Software Installation and Configuration Software Installation and ConfigurationSoftware Installation RouteFinder Setup WizardUsing RouteFinder Setup Wizard 2. Click Install Software6. The Setup Wizard Device IP Address dialog box displays Device IP Address Device MAC Address Device Firmware Version8. The Wireless Settings dialog box displays Chapter 3 - Software Installation and Configuration Password Verification Remote AccessPassword Use Local Client ListRADIUS Accounting Server IP Address RADIUS Access Server IP AddressUse RADIUS Server SecretTelephone Number IP Routing NAT Enabled and IP Routing NAT Disabled12. The Setup Wizard DNS IP Address dialog box displays Select your modem and baudrate as described on the following pages 11. The Setup Wizard Modem Settings dialog box displays14. The Setup Wizard Modem Setting dialog box re-displays Testing your Connection Chapter 4 - Telnet Using Telnet to Configure your RouteFinder Chapter 4 - TelnetInternet Access Router PasswordWAN Ethernet Settings LAN -to- LAN AccessLogin script Async Port SettingsIdle Timeout Edit login scriptAuthentication Method Remote AccessRemote Access Port Settings IP Assigned Method Chapter 4 - Telnet Assign Remote IPRADIUS Access Server IP Client Filter SettingsLoad Default Settings Router DNS IP AddressDiagnostic Type any key to return to the main menuChapter 5 - RouteFinder Manager RouteFinder Manager Chapter 5 - RouteFinder ManagerGeneral Settings Async Port 2. Click PPP SettingsWAN Ethernet Segment LAN Ethernet SegmentExternal Port IP IP Routing NAT EnabledTel Number Assign Remote Site an IP AddressCallback Settings 2. Click Remote Authentication Settings3. The Remote Connection Authentication dialog box displays Allow Remote Dial-InClient Information Remote Connection Authentication SettingsUse Local Setting No CallbackSecret Confirmed Re-enter your Shared Secret Use Radius AuthenticationAssign a specific IP address for this user IP Assigned Method for Remote Clients Remote Access SettingsRemote Client Authentication Assign an IP Address AutomaticallyEnable IP Mapping - Virtual Server Port Settings Baudrate1. From the Port Settings, click Edit Login Script Edit Login Script for Remote AccessWriting a login script for IP Routing Send and SHLogin Script # Login ScriptMeaning of Each Login Script Command Example 3 Script for Unreliable ISP 2nd ISP backupModem String Settings Dial-up/Hang-up SettingsDial-up Retry Options LAN DHCP ServerChapter 5 - RouteFinder Manager Individual Port Options DNS IP AddressChapter 5 - RouteFinder Manager IP Address Pool IP Address Mapping ReservationDelete Routing SettingsStatic Routing PC 1 WAN Ethernet RF802EW-1 LAN Ethernet WAN Ethernet RF802EW-2 What is the purpose of the routing table?Routing Table LAN Ethernet PC 2Packets Defined by TCP/IP Filter SettingsTCP/IP Service Port IP AddressPackets defined by User Enable Client Filter Settings2. Click Client Filter Settings 2. In the Packets defined by User list, select From LAN or From WAN6. Click Privileged Clients Remote Clients Applies to Remote Access Ports5. Enter the TCP/UDP Port Number and click Add LAN Local Client ListWireless Settings Encryption WEPRefresh Device List Device Name and PasswordDevice Password Device NameTo save your settings to a file Save Settings to FileLoad Settings Upgrade Firmware To Upgrade your firmware3. Record the information if necessary and click OK to exit General Diagnostic1. From the main Manager dialog box, click General Diagnostic Chapter 6 - RouteFinder Monitor Running RouteFinder Monitor RouteFinder MonitorTest Connection Chapter 6 - RouteFinder Monitor3. Select Disconnect Port 1 or Disconnect Port Terminate ConnectionSave to File 4. Click Terminate ConnectionAutosave IP Address/NameSave Now Overwrite database fileEvent Messages TCP/IP TabTime Tab Device Power Turned OnPower-On-Time Total Connection TimeWAN Ethernet Async Port Modem PowerStatus Tab Modem ReadyTx Bytes Statistics TabName Rx BytesChapter 7 - LAN Client Settings Accessing a Windows NT Server LAN Client SettingsSetting up Remote Access Clients Chapter 7 - LAN Client SettingsWin95 Windows 95/98 1. Click Start Settings Control PanelAdding the dial-up adapter NT Server Connection Win98Windows 95/98/NT Adding TCP/IP NT Server ConnectionWindows NT WinNTAdding Client for Microsoft Networks NT Server Connection Windows 95/98Dial-up Adapter Windows 95/98 Set up Properties of Components NT Server ConnectionSet Your Primary Network Logon NT Server Connection Chapter 7 - LAN Client Settings Network Client Windows 95/98 Identification Windows 95/98Make Your New Connection NT Server Connection Chapter 7 - LAN Client Settings Access Windows 95/982. Select Share-Level access control Set Dial-up type NT Server ConnectionAdding the dial-up adapter Novell Server Connection Accessing a Novell ServerDial in to your network NT Server Connection Win95/98 Adding IPX/SPX Novell Server Connection Network Client Windows 95/98 Set Up Properties of Components Novell Server ConnectionAdding Client for NetWare Networks Novell Server Connection Chapter 7 - LAN Client Settings 7. Click Properties Set Your Primary Network Logon Windows 95/98Set Dial-up type Novell Server Connection Set Your Access Control Novell Server ConnectionMake Your New Connection Novell Server Connection Dial in to your network Novell Server ConnectionAdding the dial-up adapter Novell/NT Server Connection Accessing a Windows NT Server and a Novell NetWare ServerWindows 95/98/NT 1. Click Start Settings Control Panel Adding TCP/IP Novell/NT Server Connection Adding Client for Microsoft Networks Novell/NT Server Connection Adding IPX/SPX Novell/NT Server Connection Adding Client for NetWare Networks Novell/NT Server Connection Set Your Primary Network Logon Novell/NT Server ConnectionSet Up Properties of Components Novell/NT Server Connection Network Protocol Windows 95/98 2. Click PropertiesMake Your New Connection NT/Novell Server Connection Set Your Access Control2. Select the Share-Level access control option Dial in to your network NT/Novell Server Connection Accessing a Unix ServerSet Dial-up type NT/Novell Server Connection Adding the dial-up adapter Unix Server ConnectionWin95/98 Set Up Properties of Components Unix Server Connection Adding TCP/IP Unix Server ConnectionDial in to your network Unix Server Connection Make Your New Connection Unix Server ConnectionSet Dial-up type Unix Server Connection 3. Double-click Make New Connection Make New Connection Windows 2000 only2. Double-click the Network and Dial-up Connections folder Chapter 8 LAN-to-LAN Settings Using the Find Computer command LAN-to-LAN SettingsSetting up LAN-to-LAN Routing Setting up a Windows machine to share filesUsing LMHosts Chapter 9 - Troubleshooting Chapter 9 - Troubleshooting TroubleshootingCommon Problems Problem #1Create a backup of the file c\windows\system\oleaut32.dll Chapter 9 - Troubleshooting Problem #3Problem #4 Problem #5Problem #9 Problem #8After installing my RF802EW, my modem connection seems to be slower Problem #10Chapter 10 - Service, Warranty and Technical Support Addendum for North American Products Limited WarrantyChapter 10 - Service, Warranty and Technical Support Out of Warranty Repair Costs Addendum for International ProductsSINGLE-USER SOFTWARE LICENSE AGREEMENT Software User License AgreementIMPORTANT - READ BEFORE OPENING THE SOFTWARE PACKAGE MULTI-TECH SOFTWARE LICENSE AGREEMENTThis Agreement shall be governed by the laws of the State of Minnesota Technical Support Online Warranty RegistrationUsing email Contacting Technical SupportEmail info@thesupplynet.com Ordering AccessoriesAbout the Internet Appendixes Industry Canada Appendix A - Regulatory Compliance InformationClass B Statement FCC Part AppendixesRouteFinder Monitor WINIPCFG and IPCONFIGAppendix B - Tools for your RF802EW PINGTRACERT WAN/LAN Cables Appendix C - Cabling DiagramsPin Circuit Signal Name Serial CableGlossary B Baudrate D DHCP Dynamic Host Configuration ProtocolGlossary DNS DomainNameSystemISDN TA ISP Internet Service ProviderGlossary IP Addresses L LAN Local Area NetworkPort Number NetworkAddressP Packet ProtocolGlossary T TCP/IP Transmission Control Protocol/Internet Protocol U UDP User Datagram ProtocolIndex Index