Lantronix MSS100, 1-T2 manual Emulating a Direct Serial Connection, Mssb

Page 43

Using the MSS

Emulating a Direct Serial Connection

5.3 Emulating a Direct Serial Connection

Two MSS serial servers can be connected to emulate a direct serial connection on a LAN. Servers connected in this way can pass data only. They will not be able to pass status signals (DSR, DTS, CTS/RTS, etc.) or preserve timing between characters. The basic network conÞguration for this virtual serial line is shown in Figure 5-14.

Figure 5-14:Back-to-back MSS Connection

Serial Device

Serial Device

mss_amss_b Ethernet

192.168.5.2 192.168.5.10

Assuming the MSS serial port parameters have been conÞgured properly, they would be conÞgured as follows:

mss_a

Local>> CHANGE DEDICATED TCP

 

192.168.5.10:3001T

 

Local>> CHANGE AUTOSTART ENABLED

mss_b

Local>> CHANGE ACCESS REMOTE

 

Local>> CHANGE DEDICATED NONE

 

Local>> CHANGE AUTOSTART DISABLED

NOTE: If the two Servers are on different IP subnets, the default gateway on each unit will have to be configured with the Change Gateway command (see page 4-10).

The above commands create a raw (8-bit clean) TCP connection between the serial ports of the two Servers once the units have been power-cycled. The commands for mss_a ensure that it will automatically connect to mss_b each time it is booted. Similarly, the commands for mss_b ensure that it is always available to accept connections from mss_a.

When the UDP protocol is used, there is no connection. Each MSS must be told explicitly which hosts it is allowed to accept packets from. Broadcast or multicast IP addresses can be speciÞed to allow an MSS to send packets to all hosts on a subnet.

5 - 11

Image 43
Contents Serial Server Installation Guide Part Number Contents Contact Information Troubleshooting Pinouts Iii Page Introduction Protocols TermsConfiguration SoftwareConfiguration Introduction MSS Components InstallationMSS LEDs InstallationInstallation Power-up Diagnostics 4Pinging the MSS Is It Working?Page Getting Started Using an ARP Entry and the Ping Command Using EZWebConIP Address Configuration 1Entering ARP and Ping Unix Using the Serial Console Using a DHCP, BOOTP, or Rarp ReplyControlling Incoming Logins Incoming LoginsEZWebCon Login and Configuration Rlogin Serial Port LoginsOther Incoming TCP/IP Logins Incoming LAT LoginsStarting Outbound Connections Remote Console LoginsTelnet 2 SPX Logout3 LAT Basic Configuration Command SetSystem Passwords Privileged PasswordProtocol Configuration Login Password1 TCP/IP Parameters 2 IPX/SPX Parameters LAT Parameters Serial Port ConfigurationBasic Configuration Serial Port Configuration Change Preferred SPX None Otherwise, only Telnet console port connections are possible Page Incoming Connections Using the MSSSocket Connections 1.1 TCP/IP Socket Connections LAT Connections1.2 IPX/SPX Socket Connections 4Reducing Flow Control Host ApplicationsSession Control Local SwitchInteractive Connections Code Examples8DeÞning Switches Backward and Forward SwitchesDisconnect and Resume Outgoing ConnectionsSession Limits 2.3 SPX 10Connecting with Rlogin 2.4 LAT 12Connecting to a ServiceStatus Displays Show Sessions Show Server CharacteristicsShow Services Show Server CountersMssb Emulating a Direct Serial ConnectionMultihost Mode 15Setting the MSS for Multihost Mode 1 Configuring Multihost ModeMultihost Mode Using the MSS Contact Information LANtronix Problems and Error Messages TroubleshootingTable B-1Problems and Error Messages, Etc/services Þle? Bootp TroubleshootingEntering Commands at the Boot Prompt Tftp TroubleshootingFigure B-1BCP Command Examples Entering Commands at the Boot Prompt Troubleshooting Modem Configuration Checklist Page RJ-45 Connector DB25 ConnectorPinouts DSR Data Signal Ready versus CD Carrier Detect Modem WiringDTR Data Terminal Ready Obtaining New Software Updating SoftwareVia FTP Figure D-1Lantronix FTP Session Via a ModemUpdating Software Reloading MSS Software Reloading MSS SoftwareNetWare Figure D-3Reloading Flash ROM using NetWare3 MOP 2 TCP/IPTftp Troubleshooting Flash ROM UpdatesRelative Humidity Limitations Power SpecificationsTemperature Limitations SpecificationsPage Warranty Statement EMC Declaration of ConformityIndex-i IndexIndex-ii Loadhost 4-3, 5-9, B-6Index-iii Telnet 1-4, 5-1