Lantronix Learn How to Install Your UDS Device with Technology

Page 14

3: Getting Started

Installing the UDS

Figure 3-1. UDS2100 Connected to Serial Device and Network

To install the unit:

To install the unit, complete the following steps in order. Refer to the numbers in the previous figure.

1.Connect a serial device to your unit. See 2: Introduction for more information about what kinds of device attachments the unit supports.

2.Connect an Ethernet cable to the 10/100 port.

3.Supply power to your unit using the power supply that was included in the packaging.

Note: The required input voltage is 9-30 VDC (center +) (1.8W maximum power).

4.Supply power to the serial device.

Note: If you encounter a problem, please see 11: Troubleshooting and Contact Information.

UDS2100 User Guide

14

Image 14
Contents UDS2100 User Guide Revisions Copyright & TrademarkContacts Date Rev CommentsContents Setup Mode Server Configuration Warranty Figures TablesChapter Summary Using This GuidePurpose and Audience Chapter DescriptionAdditional Documentation DocumentApplication Examples IntroductionApplications Introduction Protocol Support Additional FeaturesConfiguration Methods Product Information Label Sample Hardware Address 00-20-4A-14-01-18 or 00204A140118Package Contents Getting StartedInstalling the UDS To install the unitIP Address Required InformationHardware Address IP Address Subnet Mask GatewayAssigning an IP Address Assigning the IP Address DeviceInstallerInstalling DeviceInstaller Select Assign a specific IP address and click NextTo view the units current settings Accessing the UDS2100 Using DeviceInstallerViewing the Current Configuration Adding the Unit to the Manage ListSetting Getting StartedPress Enter within 5 seconds To configure the unit using a Telnet sessionNext Step Assigning the IP Address Serial Port Login Configuration Using Web Manager Accessing UDS2100 Using DeviceInstallerNetwork Configuration Lantronix Web ManagerSelect Obtain IP address automatically Automatic IP Address ConfigurationTo assign an IP address automatically Select Use the following IP configuration Static IP Address ConfigurationEthernet Configuration To assign an IP address manuallyServer Configuration Server ConfigurationTo configure the UDS2100’s device server settings AdvancedHost List Configuration To configure the host listRetry Settings Channel 1 and Channel 2 ConfigurationSerial Settings Host InformationPort Settings ChannelPack Control Flush Input Buffer Serial to NetworkFlush Output Buffer Network to Serial Connection Settings TCPTo configure a channel’s TCP settings Endpoint Configuration Connect Mode Passive ConnectionConnect Mode Active Connection Connect ProtocolDisconnect Mode Common OptionsDatagram Mode Connection Settings UDPTo configure a channel’s UDP settings Apply Settings Apply Factory DefaultsTelnet Connection Configuration via Telnet or Serial Port Setup ModeAccessing Setup Mode Serial Port Connection To establish a Telnet connectionExiting Setup Mode To exit setup modeIP Address Setup Mode Server ConfigurationServer Configuration Option Set Gateway IP AddressDhcp Name Change Telnet Configuration PasswordNetmask Number of Bits for Host Part Network Class Host Bits NetmaskSetup Mode Server Configuration Baudrate Setup Mode Channel ConfigurationChannel 1 Option Common I/F Mode Setting Binary Interface ModeMode Option FlowFlow Control Option Hex Connect ModePort Number Port Numbers Reserved forConnect Mode Option Active Startup Incoming ConnectionResponse Manual Connection Address Example To enable the hostlist Datagram TypeModem Mode MessageMeaning No CarrierAuto Increment Source Port Send the Escape Sequence +++ in Modem ModeModem Mode Function Command Remote Port Disconnect Mode OptionRemote IP Address DisConnModeFlush Mode Buffer Flushing Pack ControlSend Characters Packing IntervalTrailing Characters OptionSend Characters DisConnTime Inactivity TimeoutChannel Port Password Telnet Terminal TypeTCP Keepalive time in seconds Setup Mode Advanced SettingsExpert Settings Option Enable alternate MAC ARP Cache timeout in secondsDisable Monitor Mode at bootup Http Port NumberDisable Telnet Setup Security Settings OptionDisable Snmp Snmp Community NameDisable Web Server Disable Tftp Firmware UpdateDisable Port 77FE Hex Disable Web SetupExpert Settings Defaults Default Settings OptionChannel 1 and Channel 2 Configuration Defaults Security Settings DefaultsSetup Mode Advanced Settings Obtaining Firmware Reloading Firmware Firmware UpgradesUsing Tftp Graphical User Interface ROM FileUsing Tftp Command Line Interface To recover firmwareFirmware Upgrades Entering Monitor Mode Using the Network Port Monitor ModeEntering Monitor Mode Using the Serial Port Monitor Mode CommandsCommand Command Name Function Response MeaningTroubleshooting and Contact Information LEDsDiagnostic, Power, and Serial Port LEDs UDS2100 LEDs LEDs MeaningProblems and Error Messages Problem/Message Reason SolutionProblem/Message Reason Solution Technical Support Technical Support Europe, Middle East, and AfricaUDS2100 Serial Ports Serial Connector PinoutsConnections and Pinouts To reset the unit to factory defaults Reset ButtonEthernet Connector Pinouts Power Plug Network PortTechnical Specifications Category DescriptionCategory Description Transient over voltages Alternative Ways to Assign an IP Address AutoIPARP and Telnet To assign a temporary IP addressDecimal Binary Hex Converting Binary to HexadecimalConversion Table Scientific Calculator Warranty Compliance and Disclaimer Disclaimer and Supplementary Information Index

UDS2100 specifications

The Lantronix UDS2100 is a versatile device server designed to facilitate connections between serial devices and Ethernet networks. This innovative product acts as a bridge, allowing for seamless communication between legacy serial devices and modern IP-based systems. Its importance has grown, particularly in industries that still rely on serial technology but seek to integrate with contemporary IT infrastructures.

One of the main features of the UDS2100 is its ability to connect up to two serial devices simultaneously. This dual-port capability makes it an efficient solution for environments where multiple devices need to be networked without additional complexity. By enabling these connections, the UDS2100 allows for remote control and monitoring of various equipment, leading to increased operational efficiency.

The device supports a variety of communication protocols, including TCP/IP, UDP, and HTTP, ensuring compatibility with a broad range of applications. This flexibility is complemented by the UDS2100’s support for both standard and custom baud rates, making it adaptable to various serial device configurations. Users can configure the device via a web-based interface, simplifying the setup process and enhancing user experience.

In terms of security, the Lantronix UDS2100 is equipped with numerous features to protect data transmission over the network. These include support for Secure Sockets Layer (SSL) and Transport Layer Security (TLS), which encrypt the data being transmitted, ensuring that sensitive information remains protected from potential threats.

The UDS2100 also features robust diagnostic capabilities, offering real-time monitoring and logging of connections. This allows users to troubleshoot issues efficiently and maintain optimal performance of their connected devices. Moreover, the device supports multiple networking protocols, including DHCP and static IP addressing, providing further flexibility in network management.

With its compact design and robust enclosure, the UDS2100 can be easily integrated into existing systems without requiring significant modifications. Its reliability and performance make it suitable for various applications, including manufacturing, telecommunications, and medical devices. Overall, the Lantronix UDS2100 stands out as a reliable solution for businesses looking to modernize their infrastructure while maintaining compatibility with legacy equipment.